Making Connections
21
Hub-to-Hub Uplink
You can link two hubs or hub stacks to each other using any of the
twisted-pair ports or the Uplink port. Linking hubs using ordi-
nary twisted-pair ports requires crossover twisted-pair cables;
linking using one ordinary twisted-pair port and the Uplink port
requires an ordinary straight-through twisted-pair cable.
When connecting two hubs or hub stacks in this fashion, the
maximum distance between any two end-stations in a collision
domain is 205 meters. If each link between the hub and an end-
station is 100 meters, then the hub-to-hub connection is limited to
5 meters. However, if the longest hub-to-end-station connection is
less than 100 meters, then the hub-to-hub connection can be up to
100 meters long as long as the 205-meter total network diameter