TREND TB/TS Скачать руководство пользователя страница 4

TB/TS/KO, /OS, /KOS, /KOF, /KOSF Sensors Installation Instructions TG200606 Issue 2, 08/03/2011

TB/TS/KO, /OS, /KOS, /KOF, /KOSF 

Installation Instructions

Please send any comments about this or any other Trend technical publication to [email protected]

© 2011 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls Division 

of Honeywell Technologies Sàrl, Ecublens, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.

Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation 

to notify any person of such revisions or changes.

Trend control Systems limited

Albery House, Springfield Road, Horsham, West Sussex,  RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com

Trend control System uSa

6670 185

th

  Avenue  NE,  Redmond,  Washington  98052,  USA.  Tel:(425)  869-3900  Fax:(425)  869-8445  www.trendcontrols.com

5 DISpOSal

WEEE Directive :

At the end of their useful life the 

packaging and product should 

be disposed of by a suitable 

recycling centre.

Do not dispose of with normal 

household waste. Do not burn.

Units

°C

°F

Y

Input type 1 (thermistor volts)

E

Exponent

3

u

Upper

50

122

l

Lower

-5

23

p

Points

6

x

Ix

Ox (°c)

Ox 

(°F)

1

2.641

50

122

2

3.47

40

104

3

4.46

30

86

4

6.663

10

50

5

7.668

0

32

6

8.102

-5

23

Y

Input type

(thermistorKohms)

E

Exponent

1

u

Upper

3.2

l

Lower

-3.2

p

Points

4

x

Ix

Ox

1

.95

-3.1

2

1.05

-3

3

8.95

+3

4

13.05

+3.

Y

Input type

0 (volts)

E

Exponent

2

u

Upper

10

l

Lower

0

p

Points

2

x

Ix

Ox

1

0

0

2

10

10

Set up IQ Sensor types

10

Knob 

(trim -3 to +3)

Thermistor 

(0 to +40 °C)

Fan control 

(0 to 9.7)

It is recommended to use SET (software tool) for the setting of sensor type modules. For all IQ2 

series controllers with firmware version 2.1 or greater, or IQ3 series controllers, the following SET 

Unique Sensor References should be used:

Knob: 

 

Knob TB 3deg trim 

(guaranteed ±3 trim)

alternatively: 

 

Knob T 3deg trim

 (±3 ±20% linear)

Thermistor:

 

Thermistor TBTS

 (°C)

  

Thermistor TBTS F

 (°F)

Fan control: 

Fan control V

Alternatively, set scaling mode to 5 (characters) and enter scaling manually, as defined in the