Treedental TR-KID-7 Скачать руководство пользователя страница 1

TR-KID-7 Children Dental Chair

Instructions For Use

Thank you for purchasing the dental
therapy unit produced by our company.

Please read this manual carefully for
making best use of all functions of this
product.

Please keep this manual for reference in
case of problem occurred to the dental
unit.

The manufacturing of this product conforms to
the 93/42/EEC instruction issued by EU.

Содержание TR-KID-7

Страница 1: ...rapy unit produced by our company Please read this manual carefully for making best use of all functions of this product Please keep this manual for reference in case of problem occurred to the dental...

Страница 2: ...ntrolling 18 2 Emergency stop switch 20 3 Assistant tray contolling panel 20 4 Water tank 21 5 Foot controller 21 6 Valve of handpiece 22 7 Operating light 22 8 X ray film view 23 9 3 way syringe and...

Страница 3: ...er change In case of thunder please disconnect the power supply 9 Please don t touch the power plug with wet hands which may result in electric shock 10 Please don t use insecticide thinner and chemic...

Страница 4: ...nfiguration in which it will be used Guidance and manufacture s declaration electromagnetic emission The TR KID 7 is intended for use in the electromagnetic environment specified below The customer of...

Страница 5: ...arth 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply...

Страница 6: ...mpliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m NOTE 1 At 80 MHz a...

Страница 7: ...W Separation distance according to frequency of transmitter m 150 KHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 F...

Страница 8: ...N for part of equipment Dental patient chair tilt backward OFF for part of the equipment Dental patient chair tilt forward Emergency Stop Spittoon position Dental operating light Bowl flush X ray Film...

Страница 9: ...agile handle with care Keep away from sunlight Protect from heat and radioactive sources Upward Prohibited stacking of 2 Stacking limit by mass of 350 kg Symbol for the marking of electrical and elect...

Страница 10: ...ating stool doesn t belong to the basic structure of the dental multipurpose therapy unit and the guarantee period of the operating stool is three months The cold light lamp PU cushion real leather cu...

Страница 11: ...requirement for cleanness should be met The air compressor should be provided by the user and compressed air must be subject filtration with a filter pore size 50 m 2 Water supply water pressure 0 20...

Страница 12: ...ad rack extension range 120mm The biggest backward angle of the seat cushion 12 Temperature of the constant temperature water heater 40 5 Work space length 4000mm width 2600mm height 2000mm Handpiece...

Страница 13: ...11 Fuse label...

Страница 14: ...21 22 26 23 25 29 USB Motor Input 24V AC Limited position swtich procedure control box USB USB operating light film viewer 24V water heater and temperature controller AC 24V output 1 2 3 4 5 6 water...

Страница 15: ...e touching from any objects during the dental units in the working the installation space should be required the following items a The length no shorter than4000mm b The width no shorter than 2600mm c...

Страница 16: ...0mm then connect the cable plugs from patient chair please connect them according to correct numbers to the cables from spittoon unit fix the spittoon unit to patient chair by 3 pieces M10 he socket 3...

Страница 17: ...ug Operating Lamp figure 2 7 Power unit Connect the water supply tubing air supply tubing and drainage tubing to water source air source and drainage respectively During the connecting make sure that...

Страница 18: ...insert of the nozzle is not finished The meter ring should be pressed again to make the nozzle inserted till the meter ring recoils b hand piece turn on the water source and air source before install...

Страница 19: ...st be 52 mm PVC pipe The pipe interfaces should be about 40mm from ground Connection area for electricity should be properly grounded and within the installation area 4 Pipeline installation Before li...

Страница 20: ...er in the front cover The normal operating air pressure of the dental unit is 0 55Mpa If any error occurs please adjust the knob in the air filtrating and reducing valve to keep the above mentioned nu...

Страница 21: ...ot water Press the constant temperature heater will start working to heart the water to 40 in case of water temperature decrease the heater will work automatically the indicator light flashes in the c...

Страница 22: ...water supply if tap water changes please reset the time a Memory position set of the patient chair Step 1 press SET key the indicator light turns on Step 2 press key or key press one of them or neithe...

Страница 23: ...fiers direction release the switch which will then return to its original position automatically and then the patient chair will stop UP the patient chair upward DO the patient chair downward BD backr...

Страница 24: ...ir adjustment valve Handpiece 2 air adjustment valve Handpiece 3 adjustment valve Figure 1 Figure 2 Figure 3 a 1 2 3 in Figure 1 and Figure 2 correspond to the handpiece water and air amount of 1 2 3...

Страница 25: ...ment instructions To avoid the risk of biocompatibility please use the saliva ejector conform with ISO 10993 Suction low is water suction Connection through water source is required and minimum water...

Страница 26: ...lear the filter element of water fliter by mild detergent at least every 6 months the specification of filter core is less than 50 m if there is cracking or breakage in the water filter or filter cove...

Страница 27: ...EL 9 Annex Spare parts list for repairing by Maintenance staff 10 Dental handpiece and 3 way syringe tip need to be sterilized before use It is recommended to use 135 high temperature sterilization 15...

Страница 28: ...ce drips water even not under use 1 Malfunction of the air distribution valve 2 The air controller foot switch doesn t return to the original position 1 Settle or change a new pipe 2 Change a new elec...

Страница 29: ...rum is not well connected 2 The malfunction of the keys on the main control panel 3 The control box is burned such as the fuse is burned 4 The motor is broken 5 The limit switch is blocked 1 Re plug t...

Страница 30: ...etic valve DC24v water heater water heater temperature controller DC24V output strong pumpping electromagnetic valve Weak pumpping electromagnetic valve strong pumpping switch Weak pumpping switch Neg...

Страница 31: ...n instrument tray electromagnetism valve high power suction water oneway valve P A air adjustment valve water transfer switch tank 2 1 air air brake setting instrument tray air brake switch 3 4 handpi...

Страница 32: ...in pipe 3 way syringe air brake valve tank high speed heedpiec 1 high speed heedpiec 2 high speed heedpiec 3 water regutating valve holder valve chip blowing valve air adjustment valve left foot switc...

Страница 33: ...staff 2 electric motor Professional maintenance staff 14 air meter Professional maintenance staff 3 tubing Professional maintenance staff 15 valves Professional maintenance staff 4 main control keyboa...

Страница 34: ...with care and moisture proof 2 Transportation and storage environment temperature 5 40 relativity 80 pressure altitude 2000m Installed by Telephone Our company reserves the right to change product des...

Отзывы: