Tree MCT Plus 16 Скачать руководство пользователя страница 1

 

                                    Professional Weighing Equipment 

 

 

 

 

  MCT  Plus SERIES intelligent weighing scale 

   MID COUNTING SCALE 
   WITH CHECK-WEIGHING FUNCTION 

 

                       

 

 

Operation Manual 

Содержание MCT Plus 16

Страница 1: ...Professional Weighing Equipment MCT Plus SERIES intelligent weighing scale MID COUNTING SCALE WITH CHECK WEIGHING FUNCTION Operation Manual...

Страница 2: ...ervice 4 Introduction 5 Safety 6 Weight Scale 7 Functions 8 Features 9 10 Application Conformity 11 Getting Started 12 Delivery 12 Assembly Installation 13 14 Application Menu 14 Key Functions 15 Func...

Страница 3: ...ration refers conforms to the following standards Electronic scale MCT Mid Counting Scales Mark applied EU Directive Standards 2004 108 EC EN 61326 1 2006 Signature Boon Lim R D Manager Date 06 28 201...

Страница 4: ...son Court Rohnert Park CA 94928 USA Tel 707 542 2185 FAX 707 542 3285 http lwmeasurements com EUROPE LW Measurements Europe Ltd Chalkwell Park House 700 London Road Westcliff on Sea Essex SS0 9HQ Unit...

Страница 5: ...se operating instructions in their entirety so that you can make optimum use of the full potential and the diverse possibilities of the weighing scale in your daily work These operating instructions c...

Страница 6: ...dapter If there should be any reason to believe that it is no longer safe to operate the scale it should be immediately unplugged from the electricity supply pull out power adapter and secured against...

Страница 7: ...7 Rev 3 08 08 2016 Weight Scale The weighing scale consist of certain parts Weighing scale body 1 The scale pan 2 The adapter 3 Operation manual Your weighing scale 3 2 1...

Страница 8: ...Model number Capacity Division Weighing pan Size MCT P 3 3 lb 0 0001 lb 7 6 x 10 in MCT P 7 7 lb 0 0002 lb 7 6 x 10 in MCT P 16 16 lb 0 0005 lb 7 6 x 10 in MCT P 33 33 lb 0 001 lb 7 6 x 10 in MCT P 66...

Страница 9: ...ration Selectable auto back light Selectable auto shut off Unit switching kg g lb oz lb oz Variable kg or lb reference weight calibration software Pieces counting 1 3 million internal resolution 30 00...

Страница 10: ...10 Rev 3 08 08 2016 Underside of unit Battery compartment cover Hard switch Battery compartment Rechargeable battery included Leveling feet...

Страница 11: ...levant attachments and their application in accordance with instructions must be observed The weighing scale has been manufactured and tested in accordance with the standards and recommendations set o...

Страница 12: ...d be stored for a couple hours and kept in its box in a dry room at normal temperature so that no condensation settles on the unit when opening the box Check the scale immediately after unpacking for...

Страница 13: ...r complies with the local mains voltage If the operating voltage is not the same as the mains voltage the power adapter must not be connected to the mains socket and contact customer service Placement...

Страница 14: ...Fig 1 In order to get exact measurements the balance must be carefully leveled after each re location Fig 1 Correct leveling with the aid of the bubble level and adjusting feet ER Application Menu Di...

Страница 15: ...decimal position of sample weight Press the ZERO key to set or re adjust the scale to the correct zero position Pressing the TARE key eliminates the gross weight on the platter box or container etc as...

Страница 16: ...to show the total pieces on the third line of the display Press the MC key to show the unit that will be cleared Press the CE key to confirm clear Clearing the tare weight Place the empty container o...

Страница 17: ...Weight Enhancement The weighing machine will automatically adjust and calculate a new average unit weight when more samples are slowly placed on the scale This ensures higher accuracy as samples are...

Страница 18: ...re and confirm the sample weight Keep adding pieces until it reaches the lowest quantity of 990 The alarm will sound when you reach 990 Keep adding pieces until it reaches the highest quantity of 1010...

Страница 19: ...ight after calibration Turn off the power then turn it back on again Place a weight on the platter to ensure weighing is correct If not repeat the above steps Linearity calibration for scale technicia...

Страница 20: ...p solution Never use solvents acids alkalis paint thinners scouring powders or other aggressive or corrosive chemicals for cleaning these substances can cause damage to the surfaces of the scale housi...

Страница 21: ...al box If they are not properly packed an in the original box the customer pays for shipping cost If we determine there is a factory defect we will pay for the shipping back If we determine that it is...