www.traxontechnologies.com
©2020 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U.
PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide
IG0105EN V2.0 03/20
P. 11 of 19
3. The Mounting Brackets position can refer FIG.6 for reference on different tube lengths.
Mounting Brackets must not touch the cable after installed in order to prevent cable damage.
FIG.6: Bracket position for different tube lengths
L1
Item
Descriptions
L1
L2 (for ref. only)
1
Allegro Tube Mono L=500
500mm/19.7”
260mm/10.2”+10/-30mm
2
Allegro Tube Mono L=995
995mm/37.2”
700 mm/27.6”+10/-30mm
3
Allegro Tube Mono L=1490
1490mm/58.7
1200mm/47.2”+10/-30mm
4
Allegro Tube Mono L=260
260mm/10.2”
40mm/1.6” +5/-5mm
5
Allegro Tube Mono L=630
630mm/24.8”
400mm/15.7”+10/-30mm
6
Allegro Tube Mono L=1240
1240mm/48.8”
1000mm/39.4”+10/-30mm
L2
L3
The position of two mounting brackets must be located within L3 and please make sure that the space between
mounting bracket and cable loop end should be at least 5mm clearance.
5mm
5mm
4. Connect Tubes in the daisy-chained manner as detailed in the Wiring Diagram. Always
affix a Waterproof Connector End Cap (sold separately) for the OUT connector of the final
Tube in each daisy chain (see below figure).
FIG.7: Connecting the Allegro Tube Mono
IP66 CONNECTOR SEAL
End Cap Seal on Last Tube
Connector End Cap
5. The first profile of the daisy-chain group has to be connected to the control system via
the starter cable.
6. Starter cables, Data and Power cables have to be installed through conduits/trunking.
7. Set up the control system indoors as detailed in the Wiring Diagram and connect to the
Allegro Tube Mono outside. Start up each unit and verify correct function.