Installation Guide
12/19 V1.0
P. 9 of 19
2.2 Pre-Installation Checks
2.2.1
Sequence For Cable And Connector Preparation
1. Trim Cable.
2. Plan for any possible bending of cables.
3. Fix cable ends with connectors.
4. Complete sealing of connectors by tightening screw nut with spanner/wrench.
5. Unplug Dust Caps/Waterproof End Caps and keep safe for reuse.
6. Connect luminaries with power sources and data injector boxes with connection cables
in the daisy-chain manner described in the wiring diagram.
7. Open Short Test should be performed to ensure cable wires are connected correctly. Re-
crimping of wires should be done if any failures occur.
8. Perform functional check on all Allegro Linear AC.
9. Report any functional defect found to your nearest Traxon Technologies office. DO NOT
attempt to install an Allegro Linear AC with functional defects on-site.
2.2.2
Cable Bending
Cable must NOT be bent below the Minimum Bending Radius (4 x Cable Diameter) as
specified by cable manufacturer and the Non-Bendable Length of 5cm near the connector
end MUST be adhered to.
Bending radius (for conductors):
Note the minimum bending radius for
conductors > 1.5mm2.
Pull forces on the contact points can be
avoided by proceeding as follows:
a – Bend the wire as required
a
5cm
(Minimum Bending Radius)
(Non-Bendable Length)
≥
4D
D
FIG.6: Cable Bending
Avoid vertical placement of the
connectors.
If vertical installation is unavoidable:
• Add silicon glue on the surface of cable
gland.
• Layout the cable to have drip loop to
allow water run off the wire.
Silicone Glue
Silicone Glue
FIG.7: Connector vertical installation warning