FIREPLACE INSERT - SPECIFICATIONS (Continued)
FLOOR PROTECTION
:
Hearth of 45 1/4" width and 18" depth when the insert is in place (see "E" and "F" below).
CLEARANCE TO COMBUSTIBLES
:
A. Adjacent Sidewall to
Insert
19"
B. Side Facing
13"
C. Top Facing
28 1/2"
With Shield
20 1/2"
D. Mantle to Insert
30 1/2"
With Shield
22 1/2"
E. Minimum Floor
Protection-Front 18"
F. Minimum Floor
Protection-Side
8"
COMBUSTIBLE SIDEWALL
COMBUSTIBLE MANTLE
A
D
E
F
Fireplace Facing
Combustible Surface
Combustible Surface
Surround Panel
B
C
Edge of
Firebox
NOTE: For clearances, use this clearance diagram or the clearance diagram on the safety label attached
to the back of the appliance.
LEVELING BOLTS
If your fireplace is stepped down from the hearth, you will be required to use the leveling bolts located
within the hardware package.
Prior to placing the insert
in the fireplace opening,
measure the step-down.
Screw the 1/2" bolts
provided into the threaded
holes in the back corners
of the insert body and
adjust them to match the
step-down measurement.
As you install the insert the
leveling bolts may need
further adjustment. This
may be done by tilting the
insert slightly and turning
the bolts.
BOTTOM VIEW
Leveling
B o l t s