Installation
(for qualified installers only)
9
Travis Industries
4 0 4 1 0 2 8
1 0 0 - 0 1 1 5 1
Insert Clearances
•
Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture
and draperies.
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
Min. 6”
Side
Wall
Combustible or Non-Combustible Mantel
Min. 6”
Combustible Top Facing
Min. 8-1/2”
Side Facing
Min. 10”
12” Min. (from fireplace opening)
Max. 8”
See “Face
Sizing” Below
The non-combustible hearth
must be as wide as the face
and extend to both sides.
See “Face
Sizing” Below
Mantel Clearances
The mantel must be a minimum 10” above the face and a maximum 8” deep.
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it
does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Face Sizing
Lopi Discovery DVL
26”
35-3/4”
Avalon Rosario DVL
26”
35-3/4”
FPX Arched
FPX Artisan
NOTE: Artisan faces
vary in size.
26-1/2”
3-1/2"
34-3/4”
Access
Door
Radius = 45”
FPX 34
Rectangular
Bevel
Access
Door
26-1/2”
34-3/4”
Avalon
Cambridge
DVL
25-7/8”
36-3/4”
37-5/8”
2”
27-7/8”
33-5/8”
FPX 34
Architectural
Faces
Access
Door
36”
27-1/2”
* The decorative braces protrude 1/4”
2-3/8”
2-1/4”
27-1/2”
16-1/2”
Avalon
Craftsman
35-3/4”
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
27”
Avalon
Victorian DVL
Avalon
Rawhide
27”
35-3/4”