PB 36 CF Installation Requirements
PB 36 CF Reduced Mantel Height
When using this kit, disregard the combustible mantel requirements in the manual and follow the requirements
shown to the right. If you wish to place a TV above the mantel, it must meet the following requirements:
Minimum 1” air gap behind TV to wall.
The mantel must extend 2” in front of the TV and 1” to both sides.
1-1/4" (32mm)
1-3/4" (45mm)
3/4" (20mm)
3/8" (10mm)
Min. 3-1/2" (89mm)
Max. 1-1/2" (39mm)
Min. 1-1/2" (39mm)
Manifold
3-3/4"
(96mm)
Max. 120"
(3048mm)
Min. 73-3/4"
(1874mm)
5" (127mm) Alum. Flex Duct (included)
Ceiling
Upper Manifold Framing
Lower Manifold Framing
Max. 3-1/2"
(89mm)
Manifold Support Bracket
Fireplace Header
Min. 1" (26mm) Clearance from
Flex Duct to Combustibles
Min. 3-1/2" (89mm)
Max. 3" (77mm)
Min. 1/2" (13mm) *
Max. 3-1/2" (89mm)
Min. 1-1/4" (32mm)
Clearance from Top, Sides
and Back to Combustibles
ProBuilder
36 CF
Fireplace
*This area may be supported using
1” strips pf non-combustible material
spaced a minimum of 12”
b
Maximum Mantel Depth (b) With
CoolSmart TV Kit
Mantel Height
Above Base (a) With
CoolSmart TV Kit
46" (1169mm)
0" (0mm)
1" (25mm)
2" (51mm)
8" (203mm)
7" (178mm)
6" (152mm)
5" (127mm)
4" (102mm)
3" (76mm)
9" (229mm)
10" (254mm)
11" (279mm)
12" (305mm)
45" (1143mm)
44" (1118mm)
43" (1093mm)
42" (1067mm)
41" (1042mm)
40" (1016mm)
47" (1194mm)
39" (991mm)
37" (941mm)
38" (966mm)
36" (916mm)
35" (890mm)
34" (864mm)
Non-Combustible
Facing Only
ProBuilder 36
CF Fireplace
Min.
35"
890mm
a
Combustible Facing
(Min. 35" 890mm above
base of fireplace)