Travis Industries AGP Pellet Insert Скачать руководство пользователя страница 1

AGP Pellet Insert

 

• 

Masonry Fireplace 

• Factory-Built 

(Metal)Fireplace 

•  Mobile Home Approved 

 

 

--  Please read this entire manual before 

installation and use of this pellet fuel-
burning room heater.  Failure to follow 
these instructions could result in 
property damage, bodily injury, or even 
death. 

--  Contact local building or fire officials 

about restrictions and installation 
inspection requirements in your area.  

--  Save these instructions. 

 

 

Tested and Listed by:  

 

ASTM E1509-4   ULC-S628

 

 

 

 

 

Installer

:  After installation give this manual to the home-

owner and explain operation of this insert. 

Consumer

: Retain this manual for future reference. 

$10.00  

 Copyright 2015, T.I. 

Part # 100-01341 

 

4141230 

 

Travis Industries, Inc. 

www.travisproducts.com 

12521 Harbour Reach Drive 

Mukilteo, WA  98275

 

Содержание AGP Pellet Insert

Страница 1: ...n death Contact local building or fire officials about restrictions and installation inspection requirements in your area Save these instructions Tested and Listed by ASTM E1509 4 ULC S628 Installer A...

Страница 2: ...the installation and operation of your new heater an easier and more enjoyable experience We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your h...

Страница 3: ...for the First Time 26 Curing the Paint 26 Manual Mode 27 To Start 27 To Shut Down 27 To Adjust the Heat 27 To Adjust the Fan 28 Auto Fan 28 TSTAT Thermostat Mode 29 To Start the Insert in TSTAT Mode...

Страница 4: ...heater installation clearances or within the space required for charging and ash removal Do not unplug the heater if you suspect a malfunction Turn the MODE SWITCH to OFF and periodically inspect the...

Страница 5: ...r near this appliance The heater will not operate during a power outage This heater must be connected to a standard115 V 60 Hz grounded electrical outlet Do not use an adapter plug or sever the ground...

Страница 6: ...hutdown or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system The exhaust venting system should be inspected at least once every y...

Страница 7: ...ates and burn times Differences of plus or minus 20 depending on fuel quality may occur Dimensions Electrical Specifications Electrical Rating 115 Volts 3 Amps 60 Hz Watts during Start Up Sequence 350...

Страница 8: ...required for installation of this pellet heater and notify your insurance company before proceeding with installation Packing List 9 Screws for Hopper Lid Items Required AGP Pellet Door SKU 96100793...

Страница 9: ...ty and may circulate odors from the fireplace You may wish to paint the interior of the fireplace with latex paint to prevent odors from entering the home Minimum Fireplace Size Fireplace Damper Any e...

Страница 10: ...he left and has a larger plug Use a circuit tester available at hardware stores or contact an electrician to verify correct polarity and grounding WARNING CONNECTION TO A REVERSE POLARITY OR UN GROUND...

Страница 11: ...the hopper extension position Hopper Extension Position Hopper Height A Lowest Position 21 B Mid Low 21 75 C Middle Position 22 5 D Mid High 23 25 E Highest 24 The hopper extends 14 25 into the firep...

Страница 12: ...e the appropriate knock outs from the hopper walls 9 total The holes are punched out from the inside Make sure to support the hopper walls while removing the knock outs In the example below the A posi...

Страница 13: ...nsert must be placed within an undamaged masonry or factory built metal fireplace Loose bricks or other damage must be fixed Clean the fireplace before installing Minimum 36 915mm Run the power cord t...

Страница 14: ...let Vent Pellet vent connections must be sealed airtight with 500 F RTV silicone and screwed together with at least three sheet metal screws Pellet Vent Termination Termination must be a minimum 6 abo...

Страница 15: ...Installation For Qualified Installers Only 15 Travis Industries 4141230 100 01341 Travis Vent Kits 20 Vent Kit 98900052 35 Vent Kit 98900053...

Страница 16: ...0mm long Must be made with 1 45mm diameter or larger metal or aluminum duct with a metal screen attached to the end to keep out rodents P V C or other combustible materials may not be used We recommen...

Страница 17: ...nce See the illustration below for using the vent latch on the vent connector Connecting the Vent to the Vent Connector 1 Remove the vent connector from the appliance 2 Apply a bead of high temperatur...

Страница 18: ...nector to the insert Make sure the silicone gasket attached to the bottom of the vent connector is intact and remains in place Restrictor Adjustment In certain installations with excessive draft the r...

Страница 19: ...tely 14 to 16 from the fireplace opening 2 The control panel is shipped inside a box attached to the top of the insert Remove it from the box and place it near the insert 3 On older models the side pa...

Страница 20: ...s Industries 4141230 100 01341 4 Slide each side panel forward and place aside The side panels have slots that fit over the screws NOTE When re installing the side panel make sure the tabs on the pane...

Страница 21: ...anel under the wingnut push it in then slide it down into place Tighten the wingnut to secure the control panel in place 6 Carefully slide the surround panel over the hopper lid taking care to prevent...

Страница 22: ...ts on the insert Grasp the panels with both hands lift slightly then push forward until all four hooks and tabs on top of insert engage the slots on the insert Double check panel alignment to verify a...

Страница 23: ...a Masonry Fireplace L Vent Flex Section Outside air may be drawn from the ash cleanout L Vent Storm Collar Vertical Cap Cover Plate non combustible Silicone Seal the cover plate with silicone HINT Pai...

Страница 24: ...oke shelf shields damper and baffles may be removed if attached with mechanical fasteners The firebrick refractory may be removed The metal sides frame members or other structural components of the fa...

Страница 25: ...ELIES UPON ELECTRICITY TO PUSH THE FLUE GASES OUT THE PELLET VENT UNPLUGGING IT MAY LEAD TO SMOKE ENTERING YOUR ROOM FAILURE TO MAINTAIN YOUR HEATER WILL LEAD TO A RESTRICTED COMBUSTION AIR SYSTEM LEA...

Страница 26: ...Burn for 1 Hour THEN OPEN THE DOOR The insert paint is cured through heat To prevent it from bonding to the door gasket you must burn the heater for approximately 1 hour then open and close the door...

Страница 27: ...n the control panel The insert will enter the start up sequence for approximately 22 minutes To Shut Down Press the STOP button on the control panel The insert will begin the shut down process which t...

Страница 28: ...eft lower fan or right higher fan The FAN knob adjusts the speed of the insert s blower to move more heat out into the room Auto Fan Turn the FAN knob to the AUTO FAN setting on the control panel to a...

Страница 29: ...nter the start up sequence for approximately 22 minutes To Adjust the Heat Output Use the HEAT knob on the control panel to adjust the heat output NOTE Depending upon which TSTAT Program you are in 1...

Страница 30: ...the heater will resume at the HEAT output setting set at the control board Heater Set at HIGH If thermostat calls for heat thermostat closed Heater runs at setting set on control panel dial If thermo...

Страница 31: ...orm the flame will ignite and the room air blower will come on when the heater comes up to the selected temperature NOTE If the heater doesn t light 2 times in a row both the START and STOP lights wil...

Страница 32: ...inge and latch Check for air leaks Access and Clean Components Inspect Fireplace and Chimney Removing Flyash This heater was designed to allow for easy flyash removal with the included tools However t...

Страница 33: ...ERVICE Turn the handle clockwise and pull to open the door as shown below Inspect the Burn Once a week you should inspect the flame quality inside your appliance When burning on high the flames should...

Страница 34: ...he visual deflector Note how the cover has a mounting hole on the left side and hooks on the right that fit over the pins inside the firebox a Lift the right side of the visual deflector up and pull i...

Страница 35: ...the visual deflector is pressed down fully on the right side The visual deflector holds the burn platform in place and keeps it properly aligned during operation If it is not fully seated airflow to...

Страница 36: ...ush away flyash around the fire platform using the brush included with the insert The flyash will fall into the ashpan below 5 Lift the fire platform out of the firebox and remove any flyash below the...

Страница 37: ...e hopper lid open and door closed pull the insert grill up and forward as shown below NOTE Use both hands on the grill Using one hand in the middle of the grill may cause it to warp 2 Hook the cleanin...

Страница 38: ...CTING SERVICE THE ASHPAN MUST BE IN PLACE WHILE THE HEATER IS IN USE The ashpan will accumulate ash as you use the appliance See the steps below to empty the ashpan 1 Rotate the ashpan door handle clo...

Страница 39: ...before it enters the exhaust blower Remove the liners and clean the area behind them following the directions below 1 Open the door 2 Remove the top liner It is held in place with 3 tabs at the bottom...

Страница 40: ...and debris from the firebox Clean the liners before replacing Cleaning the Exhaust Duct The exhaust duct directs air to the exhaust blower Follow the directions below to clean 1 Open the door 2 Remov...

Страница 41: ...sembly from the insert 3 Place protection on top of the hearth to protect it against scratches 4 Slide the insert forward 4 to 12 to gain access to the components if necessary 5 Use a vacuum compresse...

Страница 42: ...lding the exhaust duct cover in place 11 32 nutdriver Remove the exhaust duct cover by sliding it up and off the studs the gasket will remain in place 4 Clean the exhaust blower with a bottle brush or...

Страница 43: ...move the 2 wingnuts securing the blower assembly disregard photo below Lift out and remove the convection blower from the insert as shown below NOTE Do not over tighten the wingnuts when replacing the...

Страница 44: ...URER Check the vent sections for creosote accumulation indicating a poorly burning stove Accumulation over 1 4 must be removed On vertically vented systems the dirtiest portion is often the point wher...

Страница 45: ...use 1 bushing 3 washers Checking for Air Leaks AIR LEAKS INTO THE FIREBOX WILL DECREASE THE INSERT S PERFORMANCE GREATLY LEADING TO EXCESSIVE SOOTING INEFFICIENT BURNING AND PERHAPS A MALFUNCTION Insp...

Страница 46: ...ess and hold the STOP button for 3 seconds to clear the diagnostic code RED STOP GREEN START LIGHTS FLASH ALTERNATELY Appliance ran out of fuel or hopper lid not fully close In rare cases the metering...

Страница 47: ...use Holder 5 Amp LED Bulb LED Switch Cooling Fan Exhaust Blower Push Auger Motor Inline Fuse 0 5 Amp Flow Switch Igniter Hopper Lid Switch System Disc 110 NO Metering Auger Motor Convection Blower Hop...

Страница 48: ...o not connect this appliance to a chimney flue serving another appliance Inspect and clean exhaust venting system frequently in accordance with manufacturer s instructions May be installed in a sleepi...

Страница 49: ...the extent of this warranty contact your authorized Travis retailer before installation 5 Travis Industries will not be responsible for inadequate performance caused by environmental conditions such...

Страница 50: ...sed the appliance a copy of your receipt showing the date of the appliance s purchase and the serial number on your appliance At that time you may be asked to ship your appliance freight charges prepa...

Страница 51: ...LL BOARD OR OTHER ELECTRICAL HEATER USE A LOW VOLTAGE COMPATIBLE THERMOSTAT Wired 99300650 or wireless thermostats 99300689 may be attached to this appliance Route the thermostat wires to control pane...

Страница 52: ...7 Fuel 7 Heating Specifications 7 Hopper Extension Set up 11 Important Information 2 Insert Maintenance 32 Insert Maintenance Tools 33 Inspect the Burn 33 Installation into a Factory Built Metal Fire...

Отзывы: