Page 46
Appendix 4 - Wiring Diagrams, Electrical Spec's
Printed 3/18/98
Travis Industries Pellet Stove Troubleshooting Guide (
1994)
A
UGER
M
OTOR
There are different auger motors for the insert and stove. Both rotate at 1 rpm (make sure to put a slight
amount of load on the output shaft if testing). Both are rated at .42 amp and are impedance protected.
C
ONVECTION
B
LOWER
1.1 Amp - Impedance Protected - Approximately 150 c.f.m.
E
XHAUST
B
LOWER
.95 Amp - Impedance Protected - Approximately 80 c.f.m.
B
LOWER
R
HEOSTAT
FAN
HIGH
OFF
KB ELECTRONICS (HK) LTD
MODEL KBMC-13BVNS
2.5 AMPS FL
6.0 AMPS LR
120V AC
White
Black
Pot for adjusting the "LOW"
voltage is located here
Convection Blower Rheostat
Convection Blower
To check this component, check the voltage going to the convection blower while it is running. Attach piecing
points to the multimeter probes and pierce the two wires running to the convection blower. On "HIGH" the
multimeter should read 110-120 volts (the same voltage as the outlet). On "LOW" the multimeter should read 60-70
volts. The "LOW" voltage is adjusted by turning the pot inside the rheostat housing. The "HIGH" voltage can not be
adjusted. If the voltage does not fall within the numbers listed above, replace the convection blower rheostat.
Use wire piercing tips to connect
to the convection blower wires
B
URN
R
ATE
P
OTENTIOMETER
To check this component,
use a multimeter to measure
the ohms (
Ω
) between
terminals 4 and 5. The
following ohm values should
be read when the BURN RATE
knob is adjusted to:
"OFF" 0 ohms
"LOW" 800 to 1,200 ohms
"HIGH" 1 to10 ohms
If the ohm values do not fall
within the above values, the
burn rate potentiometer will
need to be replaced.
C
A
Red
Red
Red
BURN RATE
HIGH
OFF
LOW
1
2
3
4
5
6
7
8
9
10
11
12