![Travis Industries 1924 Illuminations Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/travis-industries/1924-illuminations/1924-illuminations_owners-manual_1153976008.webp)
8 Installation
(for qualified installers only)
Travis Industries
4090216
100-01216_000
Framing Dimensions – Two Sided Configuration
•
The following framing dimensions are for two-sided installations. The framing (or insulation) may
contact the sides and back of the fireplace.
NOTE
: The depth of the enclosure may be altered to accommodate facing depth. The 7-1/4” dimension
below is based upon ½” drywall on each side.
•
The electrical line should be routed through the bottom of the framing, 5-1/2” from the left side of the
enclosure (see Figure 3, item “a”).
18-1/4"
26-3/4"
a
7-1/4"
5"
5"
Figure 3