Installation and Operations Manual
16
the panel. The alarm will have to be reset to restart the pump.
When filling the pump with oil, make sure that the
power to the pump is off because if the alarm reset button has been reset and the level switches contacts close
while filling the pump, the pump will start-up automatically.
Frequent stop/start protection.
Supplied standard on all multiplex systems. Allows each pump to run a minimum
amount of time. Frequent stop/starting can reduce coupling life and is also less efficient from a power consumption
standpoint.
Automation alternation.
Supplied standard on all multiplex systems. Allows the pumps to alternate. The primary
feature of automatic alternation is to equalize the run time on all of the pumps.
Troubleshooting
This troubleshooting chart is intended as a basic troubleshooting guide. We recommended that you consult your local
dealer for service. Each Travaini Rotary Vane Vacuum Pump system is tested and checked at the factory. Always indicate
system model and serial number when calling.
WARNING:
Before attempting any repairs, remove all power from the system by switching off the main breaker or
disconnect switch. This prevents the system from automatically starting from a vacuum switch.
PROBLEM
CHECK
1
Pump will not start.
A-B-C-D-E-F-G-H-I
2
Pump/motor will not turn
J
3
Pump is not drawing vacuum.
K-L-M-N-O-P-Q
4
Pump is overheating.
L-N-Q-R-S
5
Pump is not reaching ultimate vacuum level.
M-N-R-T-U-V-W-Y-Z
6
Pump starts, but labors and draws a very high current.
G-K-Q-AA-BB-CC-DD
7
Pump smokes at the exhaust side.
Q-EE-FF-GG-HH
8
Pump is running noisy.
R-II-JJ-KK
A
Check reset button on control panel. Overloads may have triggered.
B
Check setting of HOA switch and vacuum switches.
C
Check power. Make sure that supply voltage matches motor voltage.
D
Check electrical control panel. Make sure that all wires are tight, wires may vibrate loose during shipment or
operation.
See wiring diagram.
E
Check motor overload in control panel. Overload settings may be to low. Set overload setting in motor starter in
accordance with the motor nameplate data.
F
Check fuses. Fuses may be burned.
G
Check motor wires. Motor wires may be wired incorrectly. Look at motor wiring diagram on conduit box of motor for
correct wiring configurations.