Step 3 - Hydraulic Plumbing

Follow the plumbing schematic as illustrated.  Hoses are not provided as hose lengths vary per application.

Operation

This poppet selector valve operates by energizing TWO solenoids when a toggle switch is activated.

The cylinder located on the ports labeled “1” will operate when the corresponding toggle switch is activated.

The cylinder located on the ports labeled “2” will operate when the corresponding toggle switch is activated.

The cylinder located on the ports labeled “3” will operate when the corresponding toggle switch is activated.

Directional control is controlled by the existing tractor remote valve located in the cab.  This valve does not control direction of 

flow.  The flow coming into “P1” or “P2” determines the direction of flow in the circuit.

CAUTION:  Do not loosen or remove any fittings or the valve cartridge while there is pressure in the system or a load is being held 

up by the valve.

Existing Tractor 

Remote Valve

Содержание PoppetPLUS 3

Страница 1: ...t the equipment is in a zero energy state Before applying pressure and flow to this valve be sure that all connections are tight and the hydraulic hoses are not damaged in any way Hydraulic fluid can leak from pin holes and cause injury Visually inspect all connections and never use your hands or fingers to inspect for leaks If you are injured by injection of hydraulic fluid see a doctor Failure t...

Страница 2: ...ce This will prevent accidental shorting of the control wires to ground Attach the red power wire to a keyed power source in your fuse box Make sure that the source of power is on only when the ma chine is in operation This will prevent unwanted activation and possible battery drain The black ground wire may be connected to the equipment frame or engine block Metal to metal contact is required for...

Страница 3: ...ports labeled 2 will operate when the corresponding toggle switch is activated The cylinder located on the ports labeled 3 will operate when the corresponding toggle switch is activated Directional control is controlled by the existing tractor remote valve located in the cab This valve does not control direction of flow The flow coming into P1 or P2 determines the direction of flow in the circuit ...

Страница 4: ...river does not stick to the top of the coil use a voltmeter to check for voltage between the coil terminal and the mounting nut If the voltage is at least 11 volts the valve should be functioning When the coil is energized a click should be audible from the valve The sound may be quiet or muffled if the valve is under pressure If the voltage is low check the voltage at the source where the power w...