![TRAUSCH DYNAMICS PoppetPLUS 3 Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/trausch-dynamics/poppetplus-3/poppetplus-3_installation-manual_1153612001.webp)
Installation Guide
PoppetPLUS
3 Valve Kit - 15 GPM
Part #
9502733
Warning
To avoid serious injury or death:
•
Park the equipment on level ground, apply the parking brake, disengage running equipment, lower all implements to the
ground, shut off the engine and remove the key.
• Read and comprehend the tractor and implement or attachment owner’s manual before installing or operating this valve.
• Always wear safety glasses and proper personal protection equipment before and during installation of this valve.
• Pressurized hydraulic fluid can cause serious injury. The forces created can penetrate skin. Relieve all system pressure
before disconnecting lines. Be sure that the equipment is in a “zero-energy” state. Before applying pressure and flow to
this valve, be sure that all connections are tight and the hydraulic hoses are not damaged in any way. Hydraulic fluid can
leak from pin-holes and cause injury. Visually inspect all connections and never use your hands or fingers to inspect for
leaks. If you are injured by injection of hydraulic fluid, see a doctor. Failure to do so may cause serious injury or death.
Parts List
Part
Qty.
Description
Order #
A
1
Manifold
7068109
B
6
Valve, 2P2W, Poppet
7010128
C
6
Solenoid
7013763
D
6
Solenoid Nut
7013770
E
1
Fuse Kit
9502615
F
1
Solenoid Wire Harness
9502742
G
1
20’ Extension Wire Harness 9502743
H
1
Switch Box/Wire Assembly 9502747
I
3
Toggle Switch
5056117
J
3
Toggle Boot
5056118
K
3
Indicator Light
5056138
Document # 8889015
Power Source
+
-
D
B
C
A
E
9502615
Fuse Kit
F
G
H
I
J
K