End of Day (continued)
5
TRAULSEN TD078HT TRAINING GUIDE
1. Throughly clean fan post using alcohol or mineral
spirits and a clean, lint-free cloth.
2. Clean the bearing inside of the fan blade assembly
using a cotton swap moistened with alcohol or
mineral spirits (see fig. 1).
3. Place a few drops of the lubricant supplied by
Traulsen into the fan blade assembly rear.
4. Replace the fan blade assembly on the post.
III. Cleaning the Fan Blade(s) (required after each use)
1. Open the compressor access door.
2. Locate drain hose over a floor drain or large bucket
(see fig. 1).
3. Open drain valve by turning clockwise.
4. Spray out the display well and sanitize thoroughly.
Allow all water to run out the drain.
4. Close the drain valve by turning counter-clockwise.
Close the compressor access door.
5. Wipe out the refrigerated area behind the doors
using a non-abrasive, non-chlorinated,
stainless steel safe cleanser. Leave the door(s)
open until next use.
II. Cleaning the Cabinet (required after each use)
WARNING!
Spraying water inside the refrigerated area behind the
doors may cause equipment damage and/or injury.
fig. 1
fig. 1
IV. Completion
1. Reassemble cabinet by reversing steps 1 thru 9 on page 4.
NOTE:
Leave door(s) open until next use and power is restored.
fig. 2