-5-

Both refrigerators and freezers do not require manual 
defrosting. However, manual defrost option is available on 
the control, if required.

IV. a - OPERATION DISPLAY INDICATORS

During normal operation, the display shows either the 
temperature measured or one of the following indications:

IV. b - REFRIGERATORS

During normal operation, a refrigerator continuously 
circulates above-freezing cabinet air through the evaporator 
coil. An Off-Cycle defrost occurs every 8 hours for a 
maximum length of 50 minutes to melt any frost which may 
accumulate on the coil during the compressor “ON” cycle. 
With standard holding refrigerators, high relative humidity is 
also maintained to prevent dehydration of stored product.

IV. c - FREEZERS

During normal operation, a freezer continuously circulates 
below-freezing cabinet air through the evaporator coil. The 
coil requires a periodic defrosting for proper operation. 
This is accomplished by an automatic, compressor runtime 
activated, temperature/time terminated, defrost program. 
Depending on the door opening frequency and the ambient 
condition, the defrost may occur 3 to 8 times within each 
24-hour period.
At the start of a freezer defrost cycle, both the compressor 
and evaporator fans are off. The microprocessor control will 
read “dEF” (see figure 6).

IV. c - FREEZERS (cont’d)

The  electric  heaters  (attached  to  the  evaporator  coil  and 
drip pan) are energized. When the temperature sensor 
affixed to the coil senses 50°F, the coil and drip pan are 
fully defrosted. Both heaters and compressor are off for 5 
minutes to let the defrost water drip out completely. After 
drip time, compressor will resume operation. The evaporator 
coil fans are delayed from starting at the termination of a 
defrost cycle. Fan operation is automatically resumed after 
a short time or temp delay (whichever comes first). After 
completion, the total refrigeration system operation is then 
resumed. During defrost operation, heat is confined to the 
coil enclosure to prevent any significant rise in temperature 
within the food zone. The fan delay control function upon 
termination of a defrost cycle is two-fold. First, to prevent 
blowing warm air into the food storage area. Second, to 
prevent any condensation on the defrost coil from being 
blown into the food storage area.
The microprocessor control is set from the factory to 
terminate defrost at 25 minutes for freezers in the event of 
a sensor failure. This setting should never be tampered with, 
without first consulting the factory.

IV. d - PREP TABLE & MEGA TOP REFRIGERATOR

The prep table and mega top refrigerator will function as 
a refrigerator. Due to the open top feature, it runs slightly 
lower evaporator temperature and builds more frost on coil 
than the regular refrigerator. The prep table and mega top 
therefore utilize electric heater for more effective defrost. 
The defrost procedure is the same as in freezer described 
in section IV.c, except the defrost will be terminated at 45°F.

IV. e - REFRIGERATING PRODUCT

Centerline compact models will satisfactorily refrigerate an 
assorted load of food items. Allow space between articles to 
permit free air circulation. Do not overload at any one time 
with warm food products and expect immediate results. A 
certain amount of time is required to remove heat from items 
before operating temperatures can be attained. The system 
is designed for storage of refrigerated or frozen product.
Opening the door or drawer will increase the temperature 
in the cabinet and will require a certain amount of time 
to recover. Also, after peak service periods or after warm 
product is loaded, the refrigerator will require a certain 
amount of time for the temperature to return to the normal 
operating range.

Fig. 6

IV. OPERATION

V. OPERATION

Содержание centerline CLUC-27R-SD

Страница 1: ... centerlinefoodequipment com Form Number TR36231 Part Number 375 60363 00 Revision Date 06 09 20 OWNER S MANUAL Please Note This manual is intended for use with the above referenced equipment manufactured after May 01 2020 Instructions for the installation operation and maintenance of all Centerline by Traulsen Compacts Undercounter Refrigerators Freezers Prep Tables and Mega Tops ...

Страница 2: ...TAG LOCATION The serial tag is a permanently affixed label on which is recorded vital electrical and refrigeration data about your Centerline product as well as the model and serial number This tag is located in upper right interior compartment on all compact models I b READING THE SERIAL TAG Model The model of your Traulsen unit S N Serial Number The permanent ID of your Traulsen unit Refrigerant...

Страница 3: ...with a 5 8 socket wrench by tipping or otherwise raising the unit to allow access to them NOTE Traulsen does not recommend laying the unit down on its front or side or back However if you must only lay unit on the front of side not the back and please be certain to allow the unit to remain in an upright position afterwards for 24 hours before plugging it in so that the compressor oils and refriger...

Страница 4: ...g unit area For your safety and protection all units supplied with a cord and plug include a special three prong grounding plug on the service cord Select only a dedicated electrical outlet with grounding plug for power source NOTE DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE ROUND GROUNDING PRONG FROM THE PLUG OR USE AN EXTENSION CORD III g POWER SUPPLY The supply voltage should be checked pr...

Страница 5: ...an optional backsplash that must be installed on site To do so please follow the directions below 1 Install backsplash as shown in figure 5 The backsplash is attached with self drilling Philips head screws The outer most holes are used to install bumpers 2 Align the outer holes used for the bumpers to attach the backsplash Attach the backsplash with the just the outer holes and bumpers temporarily...

Страница 6: ... after a short time or temp delay whichever comes first After completion the total refrigeration system operation is then resumed During defrost operation heat is confined to the coil enclosure to prevent any significant rise in temperature within the food zone The fan delay control function upon termination of a defrost cycle is two fold First to prevent blowing warm air into the food storage are...

Страница 7: ...ing Depending on the level of cleaning drawer model interior fittings may require a tool to facilitate cleaning The drawer frame may be removed without tools V b CLEANING THE INTERIOR cont d To remove the drawers the lock tab must be unlocked by sliding the lock tab forward and then up to loosen the slides see figure 8 Then the drawer can be pulled out easily from the slides To remove the middle s...

Страница 8: ...e bracket pin and plastic bushing will remain in the top hinge bracket V e DOOR RE HINGING cont d Carefully lay the door down on a padded flat surface The door must be rotated 180 to mount on the other side of cabinet Remove top bushing and bottom hinge cartridge and install on opposite ends Using the newly obtained bottom hinge bracket follow the steps in reverse order to re hinge the door NOTE T...

Страница 9: ...ory completely ready for use VI a INFORMATION MENU The information available in this menu is displayed only if enabled see Configuration Parameters displayed only if ACC 0 Access to menu and information displayed Press and immediately release button With button or select the data to be displayed Press button to display value Toexitfromthemenu pressbutton orwaitfor10seconds Initiate Stand By Keeping...

Страница 10: ... duration is influenced by a series of parameters Time termination T2 NO and T3 different from 2EU the evaporator temperature is not monitored and defrost will last as long as time DTO Temperature monitoring of one evaporator T2 YES and T3 different from 2EU In this case if the sensor T2 measures the temperature DLI before the time DTO elapses defrost will be terminated in advance VI c INITIATING ...

Страница 11: ...A Evap Fan 16A resistive 4 FLA 12 RLA 8A resistive 4 FLA 12 RLA Defrost 16A resistive 4 FLA 12 RLA 16A resistive 4 FLA 12 RLA Auxiliary loads 1 7A resistive 7A resistive Auxiliary loads 2 7A resistive 7A resistive Input NTC 10KΩ 25 C LAE Part No SN4 Measurement Range 0 5 within the measurement range Operating Conditions 10 50 C 15 80 r H CE Approvals and Reference Norms EN60730 1 EN60730 2 9 EN550...

Страница 12: ... increase CRN defrost is based off of compressor run time time is based off of DAT DFT 0 250 Time interval among defrosts in x10 minutes When this time has elapsed since the last defrost a new defrost cycle is started Each number is multiplied by 10 minutes 0 250 indicates 0 2500 minutes DAT 0 100 hours Frost accumulation timeout DFB NO YES Defrost timer backup With DFB YES after a power interrupt...

Страница 13: ...n stop in x10 seconds With FT2 0 the fans remain on all the time FT3 0 180 Timed fan run in x10 seconds With FT3 0 and FT2 0 the fans remain off all the time ATM NON ABS REL Alarm threshold management NON all temperature alarms are inhibited the following parameter will be ACC ABS the values programmed in ALA and AHA represent the real alarm thresholds REL the alarm threshold is obtained by the su...

Страница 14: ...ON DOR ALR IISM RDS DI1 digital input operation NON digital input 1 not active DOR door input ALR when the input is on an alarm is generated if AHM STP the compressor is stopped and the defrosts are suspended IISM when the input is on the controller will use group 2 parameters RDS when the input is on a defrost is started remote control D1A OPN CLS DI1 digital input activation OPN on open CLS on c...

Страница 15: ...rator temperature measurement OS3 12 5 12 5 Probe 3 offset AHM NON ALR STP Operation in case of high condenser alarm NON high condenser alarm inhibited ALR in case of alarm HC flashes in the display and the buzzer is switched on STP in addition to the alarm symbols displayed the compressor is stopped and defrosts are suspended AHT 50 110 Condensation temperature alarm referred to T3 probe TLD 1 30 ...

Страница 16: ...S AND WIRING DIAGRAM Indications Control Wiring Diagram Thermostat output Fan output Defrost output Activation of 2nd patameter set Alarm Manual activation Increase button Exit Stand by button VI CONTROL BASICS continued ...

Страница 17: ...n both cases allow adequate time for the cabinet to recover its normal operating temperature c Control setting too high readjust per instructions on section VI b d Check that condensing coil is clean 4 Food compartment is too cold a Perhaps a large quantity of very cold or frozen food has recently been added Allow adequate time for the cabinet to recover its normal operating temperature b Adjust t...

Страница 18: ...n Other 3 Symbol 4 WEEE Symbol 5 Safety Symbol 6 Sanitation Symbol 7 Energy Symbol 8 Customer QR Code Other 4 Device Part Number PartNum UL NSF Notes SCAN FOR SERVICE INFO COMPONENTS COMPOSANTS COMPONENTES COMP AMPS EVAP FAN AMPS COND FAN AMPS LIGHT WATTS DEF HTR AMPS CTRL AMPS DOOR HTR AMPS MIN AMPS MAX AMPS 370 60297 00 REV A 11 20 14 4401 Blue Mound Rd Ft Worth TX 76106 800 825 8220 Input Power...

Страница 19: ...rs or installation by unauthorized third parties Additionally the Equipment is intended only for commercial use and should not be used by consumers or households or in any non commercial application This Domestic Warranty does not apply to and shall not cover any Equipment that is installed or used in any way in any residential or non commercial application No warranties express or implied are pro...

Страница 20: ...Number 375 60363 00 Revision Date 06 09 20 Traulsen All Rights Reserved 4401 Blue Mound Road Fort Worth Texas 76106 USA Phone 800 825 8220 Service Fax 817 740 6757 E mail service traulsen com Website centerlinefoodequipment com ...

Отзывы: