background image

2

3

Safety Information

Safety Information

The warning signs and symbols are essential to ensure your correct and safe use of 

this product and protect you and others from injury. Please kindly find the meanings of the 

warning signs and symbols, which you may encounter in the label and user manual, as 

follows:

Safety and Usage Information

CAUTION

Symbol for “THE OPERATION 

GUIDE MUST BE READ”

Symbol for “MANUFACTURER”

Symbol for “ENVIRONMENT 

PROTECTION – Waste electrical 

products should not be disposed of with 

household waste. Please recycle where 

facilities exist. Check with your local 

authority or retailer for recycling advice”

Symbol for “SERIAL NUMBER”

Symbol for “DIRECT CURRENT”

Symbol for “COMPLIES WITH EU 

REQUIREMENTS”

Symbol for “MANUFACTURE 

DATE”

The Bluetooth Combination Mark

Tips

To ensure the accuracy of measurement, please follow below instructions when 

you start measurement.

Place the scale on a flat, hard surface. Soft surface such as carpet will affect the 

performance of the scale.
Step onto the platform with bare feet. Stand still and keep full contact with the electrodes 

until the measurement is complete.
Start measurement at least two hours after Getting up or Dinning.
Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and 

dinning.
Always start measurement in the same time slot and on the same scale located on the 

same flat, hard surface.

INDICATIONS FOR USE

The Transtek Body Fat Analyzer measures weight and uses bio-electrical impedance analysis 

(BIA) technology to estimate BMI,calories,body fat, total body water percentage, bone mass, 

and muscle mass in generally healthy children 10-17 years old and healthy adults. 

It is intended for use in the domestic setting only. 

For maximum accuracy and repeatability , it is recommended that you should use the 

device in the same time of the day and on the same location. 

Body fat percentage estimates will vary with the amount of water in the body, and can 

be affected by dehydration or over-hydration due to such factors as alcohol consumption, 

menstruation, illness, intense exercise, etc.

The condition of the skin on the bottom of your feet can affect the reading. The natural 

effects of aging or activity can make this skin hard. Take the reading with clean, slightly 

damp feet for best accuracy. If you are having a problem on operating this scale please 

contact customer service.

     Transtek’s Body Fat Analyzer LS208-B7 offers you a seamless way to manage your health. 

Please be aware that this device is designed for healthy population over 10 years old self-measuring 

and self-monitoring body compositions. Any information provided by this device is in no way meant to 

treat, cure or prevent any disease or illness from happening. If in doubt, contact your physician.

     This device is contraindicated for any female subject who may be suspected of, or is pregnant. 

Otherwise, the effects of this device on the fetus are unknown.

     This device is contraindicated for any person who is connected to a wearable or implantable electronic 

device or instrument such as a pacemaker or defibrillator.

     This device should not be used for anyone who is acutely or chronically ill because of suffering from a 

disease or taking medications that affect your water levels. The accuracy of readings for these patients 

has not been verified. Specific medical advice should be obtained from a physician.  

     LS208-B7 is equipped with data transmission function. It may emit electromagnetic energy so as 

to perform its intended function. Nearby portable and mobile RF communications equipment can affect 

the performance of LS208-B7. And the device can interfere vicinity electrical equipment.

      Manufacturer will make available on request circuit diagrams, component parts list,etc.

     WARNING:No modifications of this equipment is allowed. This may result in increased EMISSIONS 

or decreased IMMUNITY of LS208-B7.

     Please use the device according to the user manual. Any misuse can cause electric shock,burns, fire 

and other unexpected hazards.

    Please use and storage the device under the environment which was provided in the user manual. 

    Don’t expose the device to extreme temperatures, direct sunlight, moist or corrosive environment.

    Do not step on the scale when your body or feet are wet, especially after bathing or showering to 

prevent slipping.

    Please keep the device out of reach of infants, children or pets, since inhalation or swallowing of small 

parts is dangerous or even fatal.

    Please don't use the device out of lifetime any more because degraded sensors and electrodes, or 

loosened electrodes can degrade performance or cause other problems.

     If you have an allergy to stainless steel

please avoid to contact to the electrodes of the device.

    The patient is an intended operator. The patient can measure, transmit data and charge battery under 

normal circumstances and maintain the device and its accessories according to the user manual.  

Содержание GBF-1257-B

Страница 1: ...duct and keep the manual well for further reference in case you have problems Thank you very much for selecting the Transtek Body Fat Analyzer LS208 B7 GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO LTD Zo...

Страница 2: ...eration Start Measuring First Measurement Daily Measurement Manage Your Health Data Transmission Troubleshooting Error Prompt When Measuring When Data Transmitting Specifications Maintenance Warranty...

Страница 3: ...tact customer service Transtek s Body Fat Analyzer LS208 B7 offers you a seamless way to manage your health Please be aware that this device is designed for healthy population over 10 years old self m...

Страница 4: ...esult Stone Pound Kilogram Percentage Foot Centimeter Age User ID P1 P8 Successful Bluetooth Connection Data transmitting pending to transmit to wireless wellness system Low Battery Calorie Analysis R...

Страница 5: ...ntioned above is less than 0 5mA However please be aware that anyone with an wearable or implantable medical electronic instrument such as a pacemaker must avoid using this device The intended use of...

Страница 6: ...ID the system will divert to Gender setting automatically As pictured below the portrait blinks The operator may press the function key or to select Gender Male Female Male Athlete Female Athlete Pres...

Страница 7: ...nal weight reading scale No special programming steps are required Once the scale is initialized as previously described you may simply step on the scale to measure your current weight For only weight...

Страница 8: ...sfully pair up with your smartphone the measurement data will be transmitted to your mobile via Bluetooth ONLY when the measuring results are attached to a specific User ID will it be transmitted to y...

Страница 9: ...Abnormal measuring results Too high OR Too low OR Huge difference between two recent measurement No display on LED when the device powers on CANNOT proceed to analyze calorie BMI body fat total body...

Страница 10: ...on 0 1kg 0 2lb 1lb 20st Accuracy 5 50kg 0 3kg 100 150kg 0 5kg Working Environment Storage Environment Power Source 6V Four AAA size Batteries Turn on Method SENSE ON technology Auto OFF Accessories 1...

Страница 11: ...Frequency Interface Requirements FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed...

Страница 12: ...ter measure of fitness than weight alone the composition of your weight loss could mean you are losing muscle mass rather than fat you could still have a high percentage of fat even when a scale indic...

Страница 13: ...n help maintain healthy bones Like muscle bone is a living tissue that can respond to exercise by becoming stronger For most people bone mass peaks in their thirties Then people begin to lose bone Reg...

Страница 14: ...e Not applicable Table 2 Guidance and MANUFACTURER S declaration electromagnetic IMMUNITY for all ME EQUIPMENT and ME SYSTEMS Compliance level Electromagnetic environment guidance 6 kV contact 8 kV ai...

Страница 15: ...be less than V1 V m The device is intended for use in the electromagnetic environment specified below The customer or the user of the device should assure that it is used in such an environment Portab...