- 3 -
III. Operation Process
1. Set Temperature Required
Turn on power switch, temperature
light is ON. The digital display shows
.
Press
button, the
light is
on (C denotes Celsius). Press
arrows “
△
” or “
▽
” to select “
℃
” or
“
℉
” (F denotes Fahrenheit)
Press
button, the temp
light
is on. Select the temperature using
the up and down arrows.
2. Set Time Required
Press
button, the temp light is
on. Select the temperature using the
up and down arrows.
Press
button after time setting;
the display shows the temperature
starting to rise. “CD-L” shows the
time counting down during your
transfer.
If there is a difference between the
actual temperature and temperature
shown on the controller, you can use
P5 mode to calibrate the difference.
For example, when actual heat
platen temperature is 180
°
C but
the display shows 200
°
C, press
button for 5 seconds to enter the P5
mode. When enter P5 mode, press
UP button
“△”
to set to- 20, and
then press button again for 5
seconds return to operation mode.
When actual heat platen temperature
is 200
°
C but the display shows 180
°
C, press Down button
“▽”
to set
to 20, and then press button 5
seconds return to operation mode
Содержание Select MP882
Страница 1: ...1 TransPro Select Cap Auto Heat Press Model No MP882...
Страница 4: ...4 IV Circuit Diagram...