background image

- 3 - 

 

 

 

 

 

 

III. Operation Process

 

 

 

1. Set Temperature Required

 

 

 

 

 

 

 

Turn on power switch, temperature 
light is ON. The digital display shows 

.

 

Press  

 

button, the  

 

light is 

on (C denotes Celsius). Press 
arrows “

” or “

” to select “

” or 

” (F denotes Fahrenheit) 

 

Press  

 

button, the temp 

light 

is on. Select the temperature using 
the up and down arrows.  

 

 

 

2. Set Time Required

 

 

 

 

 

 

 

 

 

 

Press  

 

button, the temp light is 

on. Select the temperature using the 
up and down arrows.  

 

Press  

 

button after time setting; 

the display shows the temperature 
starting to rise. “CD-L” shows the 
time counting down during your 
transfer.

 

If there is a difference between the 
actual temperature and temperature 
shown on the controller, you can use 
P5 mode to  calibrate the difference. 
For example, when actual heat 
platen temperature is  180 

°

C but 

the display shows 200

°

C, press 

button for 5 seconds to enter the P5 
mode. When enter P5 mode, press 
UP button 

“△”

to set to- 20, and 

then press button again for 5 
seconds return to operation mode. 
When actual heat platen temperature 
is 200 

°

C but the display shows 180

°

C, press Down button

“▽”

to set 

to 20, and then press  button 5 
seconds return to operation mode 

 