5/8
6-1620026 rev.P4 22/02/2016
1
2
3
8
7
6
5
4
RELA
Y 1
RELA
Y 2
P2
P1
P3
PO
TENTIOMETER
DISPLA
Y
OUT1
OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
Transmitter #3
Transmitter #4
Door operator #1
Door operator #2
Transmitter #2
PUSH
TO OPEN
Transmitter #1
PUSH
TO OPEN
PUSH
TO OPEN
PUSH
TO OPEN
10
MODE 3 - VESTIBULE SEQUENCING OPTION (1)
MODE 3 - Vestibule sequencing, type 1
Program the transmitters 1&4 on the relay 1.
The transmitters 1&4 activate the relay 1 for the
TON1
time. Then, after the
TDLY
time, they activate the relay 2 for the
TON2
time.
Program the transmitters 2&3 on the relay 2.
The transmitters 2&3 activate the relay 2 for the
TON2
time. Then, after the
TDLY
time, they activate the relay 1 for the
TON1
time.
PROGRAMMING - STEP BY STEP
1.
Press briefly the P1 button. The display shows
rad1
.
2. Press the button of the transmitter #1. The display shows
done
.
3. Press the button of the transmitter #4. The display shows
done
.
4.
To quit, press briefly the P1 button.
5.
Press briefly the P2 button. The display shows
rad2
.
6. Press the button of the transmitter #2. The display shows
done
.
7. Press the button of the transmitter #3. The display shows
done
.
8.
To quit, press briefly the P2 button.
9.
To enter the menu, press briefly the P3 button.
10. Set the item
funCt
to
3
.
11.
Press briefly the P3 button.
12. Set the
ton1
time to the desired value.
13.
Press briefly the P3 button.
14. Set the
ton2
time to the desired value.
15.
Press briefly the P3 button.
16. Set the
tdLY
time to the desired value.
17.
Press briefly the P3 button.
18.
Press briefly the P3 button.