Transmitter Solutions BC-2010 Скачать руководство пользователя страница 8

 

8

To delete a 

card

 user by card. Note users 

can be deleted continuously without 

exiting programming mode 

2   Read Card    #  

 

To delete a 

card 

user by user ID. This 

option can be used when a user has lost 

their card 

2   User ID   # 

 

To delete a 

card

 by card number(8 digits)

8    Input 8 digits Card number      # 

Cards can be deleted continuously without exiting 

programming mode 

To add a 

card and PIN

 user in card and PIN mode (3      1      #

 

)

 

To Add a 

card

 and 

Pin

 user 

(The PIN is any four digits between 0000 

& 9999 with the exception of 1234 which 

is reserved.) 

Add the card as for a card user   

Press 

  *

 to 

exit from the programming mode 

Then allocate the card a PIN as follows: 

  *    Read card 1234 # PIN # PIN # 

To change a 

PIN 

in card and PIN mode 

(Method 1) Note that this is done outside 

programming mode so the user can 

undertake this themselves

 

 *  Read Card  Old PIN #   New PIN #   New PIN #

 

To change a 

PIN 

in card and PIN mode 

(Method 2) Note that this is done outside 

programming mode so the user can 

undertake this themselves

 

 *  ID number #  Old PIN #   New PIN #  New PIN #

 

To delete a 

Card and

 

PIN 

user just delete 

the card

 

2   User ID   # 

To add a 

card 

user in card mode (3      0      #

 

To Add and Delete a 

card

 user 

The operating is the same as adding and deleting a card 

user in 3   2   # 

To delete 

All users

 

To delete

 ALL users. 

Note that this is a 

dangerous

 option so use with care

 

2   0000   # 

To unlock the door 

For a 

PIN

 user 

Enter the PIN    then press # 

For a 

card

 User 

Read card 

For a 

card and PIN

 user 

Read card

 

then enter

 

PIN # 

Содержание BC-2010

Страница 1: ...Model BC 2010 HID EM Keypad Reader Controller User Manual...

Страница 2: ...be logged in To change the master code 0 New code New code The master code can be 6 to 8 digits long To add a PIN user 1 User ID number PIN The ID number is any number between 1 1500 The PIN is any f...

Страница 3: ...ehouses laboratories banks and prisons 4 Features z Strong Zinc Alloy Electroplated anti vandal case z Full programming from the keypad z 1500 uses supports Card PIN Card PIN z Can be used as a stand...

Страница 4: ...d Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button DOTL External Alarm Dimensions L128 x W82 x H28 mm Net Weight 500 g Gross Weight 700 g 6 Installation z Remove the back cover fr...

Страница 5: ...Input Black GND 0V DC Regulated Power Input Blue NO Relay output NO Purple COM Relay output COM Orange NC Relay output NC Connection Diagram Notes BC 2010 uses a standard 10 pin connector J1 The diag...

Страница 6: ...mper alarm will operate 10 Sound and Light indication Operation Status Red Light Green Light Yellow Light Buzzer Power on Bright Short Ring Stand by Bright Press keypad Short Ring Operation successful...

Страница 7: ...ID number Users can be deleted continuously without exiting programming mode To change the PIN of a PIN user This step must be done out of programming mode ID number Old PIN New PIN New PIN To add a...

Страница 8: ...rd a PIN as follows Read card 1234 PIN PIN To change a PIN in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New...

Страница 9: ...t closed properly the inside buzzer and alarm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute To disable door open detection Factory de...

Страница 10: ...BC 2010 operating as a Controller In this mode the BC 2010 supports a Wiegand 26 bit input so an external Wiegand device with a 26 bit output can be connected to the Wiegand input terminals on the BC...

Страница 11: ...r one for entry and the other for exit Either device acts as the controller and reader at the same time Users can be enrolled on either of the devices In this mode the user capacity for one door can b...

Страница 12: ...received including interference that may cause undesired operation NOTE 1 Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipm...