P a g e
|
10
2.5
GROUNDING REQUIREMENT
➢
All function modules’ good grounding is the basis of reliability and stability of
devices. Also, they are the most important guarantee of lightning arresting and
interference rejection. Therefore, the system must follow this rule.
➢
Coaxial cable’s outer conductor and isolation layer should keep proper electric
conducting with the metal housing of device.
➢
Grounding conductor must adopt copper conductor in order to reduce high
frequency impedance, and the grounding wire must be as thick and short as
possible.
➢
Users should make sure the 2 ends of grounding wire well electric conducted and
be antirust.
➢
It is prohibited to use any other device as part of grounding electric circuit
➢
The area of the conduction between grounding wire and device’s frame should
be no less than 25mm
2
.
2.5.1
FRAME GROUNDING
All the machine frames should be connected with protective copper strip. The
grounding wire should be as short as possible and avoid circling. The area of
the conduction between grounding wire and grounding strip should be no less
than 25mm
2
.
2.5.2
DEVICE GROUNDING
Connecting the device’s grounding rod to frame’s grounding pole with copper
wire.