Transition Networks SPSVT26xx-100 Скачать руководство пользователя страница 3

INTERFACE STANDARDS AND CABLE OPTIONS SUPPORTED

Interface Cable Options

Function

Connector Type

Length

TN P/N

V.35 DTE

34-pin Rectangular Male

3-Meter

35DTE-3

V.35 DCE

34-pin Rectangular Female

3-Meter

35DCE-3

X.21 DTE

15-pin D-sub Male

3-Meter

21DTE-3

X.21 DCE

15-pin D-sub Female

3-Meter

21DCE-3

RS-232 DTE

25-pin D-sub Male

3-Meter

232DTE-3

RS-232 DCE

25-pin D-sub Female

3-Meter

232DCE-3

RS-449 DTE

37-pin D-sub Male

3-Meter

449DTE-3

RS-449 DCE

37-pin D-sub Female

3-Meter

449DCE-3

RS-530 DTE

25-pin D-sub Male

3-Meter

530DTE-3

RS-530 DCE

25-pin D-sub Female

3-Meter

530DCE-3

RECOMMENDED MAXIMUM CABLE LENGTHS

Recommended cable lengths for each interface at various data rates.

Data Rate:

V.35/RS-449/RS-530

X.21

RS-232C

10 Mb/s

35 ft. / 10 m

N/A*

N/A*

6 Mb/sec

65 ft / 19 m

N/A*

N/A*

2 Mb/sec

150 ft. / 45 m

50 ft. / 15 m

N/A*

1 Mb/sec

300 ft. / 90 m

100 ft. / 30 m

N/A*

512 Kb/sec

600 ft. / 180 m

200 ft. / 60 m

N/A*

256 Kb/sec

1200 ft./ 365 m

400 ft. / 120 m

N/A*

128 Kb/sec

2400 ft. / 730m

800 ft. / 240 m

N/A*

56 Kb/sec

3000 ft. / 910 m

1600 ft. / 480 m

10 ft / 3 m

1.2 Kb/sec

3000 ft. / 910 m

3000 ft. / 910 m

50 ft / 15 m

*N/A - Not Applicable (rates not specified for the interface in question)

CABLE SPECIFICATIONS

Fiber Cable

MULTIMODE

Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

SPSVT2613-100

1300 nM

Fiber-optic Transmitter Power:

min: -19.0 dBm

max:  -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Minimum Link Budget

11 dB

Typical Maximum Cable Distance: 2 kilometers

SPSVT2611-100

1300 nM

Fiber-optic Transmitter Power:

min: -19.0 dBm

max:  -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Minimum Link Budget

11 dB

Typical Maximum Cable Distance: 2 kilometers

SINGLEMODE

Fiber Optic Cable Recommended: 9 µm singlemode fiber

SPSVT2612-100

1300 nM

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Minimum Link Budget

16 dB

Typical Maximum Cable Distance: 20 kilometers

SPSVT2614-100

1300 nM

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Minimum Link Budget

16 dB

Typical Maximum Cable Distance: 20 kilometers

SPSVT2629-100/

1310 nM TX/1550 nM RX

SPSVT2629-101

1550 nM TX/1310 nM RX

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Minimum Link Budget

9 dB

Typical Maximum Cable Distance: 20 kilometers

SPSVT2629-102/

1310 nM TX/1550 nM RX

SPSVT2629-103

1550 nM TX/1310 nM RX

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Minimum Link Budget

9 dB

Typical Maximum Cable Distance: 40 kilometers

14

3

SPSVT26xx-100

Содержание SPSVT26xx-100

Страница 1: ...en in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de créer des interférences radioélectriques il appartiendra alors à l utilsateur de prende les measures spécifiques appropriées Trademark Notice All registered trademarks and trademarks are the property of their respective ...

Страница 2: ...de fiber support 850 1300 1500nm at distances up to 80km Standalone versions NOTE All interfaces are converted at the physical level so the network administrator can mix and match signals as RS 449 to V 35 RS 530 to X 21 DTE to DTE DTE to DCE DCE to DCE 15 2 DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model SPSVT26xx 100 Series Media Co...

Страница 3: ...iber 85 125 µm multimode fiber 50 125 µm multimode fiber SPSVT2613 100 1300 nM Fiber optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Minimum Link Budget 11 dB Typical Maximum Cable Distance 2 kilometers SPSVT2611 100 1300 nM Fiber optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm...

Страница 4: ...or similar device and referring to drawing for jumper positions move jumper 5 Carefully replace cover on media converter 6 Replace four 4 screws that secure cover to media converter 4 13 SPSVT26xx 100 4 Are the C opper L ink and F iber L ink LEDs flashing indicating loopback mode YES Disable loopback function In Hardware mode set loopback switch to N ormal position In Software mode at SNMP interfa...

Страница 5: ...rter illuminated NO Is the power adapter cord inserted properly into the media converter Is the power adapter cord installed properly at the external power source Does the external power source provide power If using SNMP management has media converter been powered OFF at software interface Contact Technical Support 800 260 1312 YES Proceed to step 2 2 Is the C opper L ink LED illuminated NO Are c...

Страница 6: ...he loopback function disabling the switches except when the Terminal Timing switch is set to Position F asynchronous mode NOTE Setting the Terminal Timing switch to Position F overrides the S software mode setting and selects Asynchronous mode OPERATION Using Status LEDs Use the status LEDs to monitor media converter operation in the network C opper L ink Steady LED indicates copper link is up fla...

Страница 7: ...r to RX location on attached device 3 Connect cable with connector installed at RX location on media converter to TX location on attached device Set Terminal Timing Switch NOTE The sixteen position Terminal Timing switch located at the SPSVT29xx 100 media converter side allows the network administrator to configure the media converter for network conditions Insert small flatblade screwdriver or si...

Страница 8: ...et the Loopback switch to the N ormal position Signal connection during loop back Illustrating RS530 DCE Power the SPSVT29xx Series Media Converter 1 Install Power Adapter cord at back of media converter 2 Connect Power Adapter 3 prong plug to AC power 3 Verify that media converter is powered by observing illuminated LED s 8 9 SPSVT26xx 100 ...