Publication date: Mar. 2016
33600 Rev B
98
Diagnostic LEDs:
System LED :
Power
Per Port LED:
10/100/1000M TP Port 1 to 20
: LINK/ACT, SPD
1000M SFP Fiber Port 21 to 24
: LINK/ACT, SPD
The System LED displays red light alarm for the 4 cases below:
1. Voltage >= 13.2V or Voltage<=10.8V.
2. FAN speed <= 500 rpm or FAN speed >=9000 rpm.
3. Inlet temperature >=45 deg. Celsius or temperature near power >=70 deg Celsius.
4. When Loop Detection is enabled and looping occurred.
Power Requirement :
AC
Voltage
: 100
∼
240 V
Frequency
: 50
∼
60 Hz
Consumption
: 16W
PoE output Max. : 370W
Ambient Temperature
:
0
°
to 40
°
C
Humidity
:
10% to 90%
Dimensions
:
44(H) x 442(W) x 211.2(D) mm
Complies with FCC Part 15 Class A & CE Mark Approval
Safety Compliance : LVD
Management Software Specifications
System Configuration
Auto-negotiation support on 10/100Base-TX
ports, Web browser can set transmission speed
(10/100Mbps) and operation mode (Full/Half
duplex) on each port, enable/disable any port,
set VLAN group, set Trunk Connection.
VLAN Function
Port-Base / 802.1Q-Tagged, allowed up to 16
active VLANs in one switch.
Trunk Function
Ports trunk connections allowed
Quality of Service (QoS)
Referred as Class of Service (CoS) by the
IEEE 802.1P standard
Two queues per port
Network Management
Web browser support based on HTTP Server
Note: Any specification is subject to change without notice.