background image

Transition Networks 

 

SM24DPB Install Guide 

33681 Rev. B  

https://www.transition.com

  

Page 

8

 of 

24

 

Rate

 

Limiting

 

 

Ingress

 

policer

 

 

Egress

 

shaping

 

and

 

rate

 

control

 

 

Per

 

port

 

Management

 

 

DHCP

 

Server

 

Support

 

DHCP

 

server

 

to

 

assign

 

IP

 

to

 

DHCP

 

clients

Remote

 

Monitoring

 

(RMON)

 

Embedded

 

RMON

 

agent

 

supports

 

RMON

 

groups

 

1,2,3,9 (history,

 

statistics, alarms,

 

and

 

events)

 

for

 

enhanced

 

traffic

 

management,

 

monitoring

 

and

 

analysis

 

Port

 

Mirroring

 

Traffic

 

on

 

a

 

port

 

can

 

be

 

mirrored

 

to

 

another

 

port

 

for

 

analysis

 

with

 

a

 

network

analyzer

 

or

 

RMON

 

probe.

 

Up

 

to

 

N

1

 

(N

 

is

 

Switch’s

 

Ports)

 

ports

 

can

 

be

 

mirrored

 

to

 

single

 

destination

 

port.

 

A

 

single

 

session

 

is

 

supported.

 

UPnP

 

The

 

Universal

 

Plug

 

and

 

Play

 

Forum,

 

an

 

industry

 

group

 

of

 

companies

 

working

 

to

 

enable

 

device

to

device

 

interoperability

 

by

 

promoting

 

Universal

 

Plug

 

and

 

Play.

 

sFlow

 

The

 

industry standard

 

for

 

monitoring

 

high

 

speed

 

switched

 

networks.

 

It

 

gives

complete

 

visibility

 

into

 

the

 

use

 

of

 

networks

 

enabling

 

performance

 

optimization,

 

accounting/billing

 

for

 

usage,

 

and

 

defense

 

against

 

security

 

threats

 

IEEE

 

802.1ab

 

(LLDP)

 

 

Used

 

by

 

network

 

devices

 

for

 

advertising

 

their

 

identities,

 

capabilities,

 

and

 

neighbors

 

on

 

an

 

IEEE

 

802ab

 

local

 

area

 

network

  

 

Support

 

LLDP

MED

 

extensions

 

Web

 

GUI

 

Interface

 

Built

in

 

switch

 

configuration

 

utility

 

for

 

browser

based

 

device

 

configuration

CLI

 

(Command

 

Line

 

Interface)

For

 

users

 

to

 

configure/manage

 

switches

 

in

 

command

 

line

 

modes

 

Dual

 

Image

 

Independent

 

primary

 

and

 

secondary

 

images

 

for

 

backup

 

while

 

upgrading

 

SNMP

 

SNMP

 

version1,

 

2c

 

and

 

3

 

with

 

support

 

for

 

traps,

 

and

 

SNMP

 

version

 

3

 

user

based

 

security

 

model

 

(USM)

 

Firmware

 

Upgrade

 

 

Web

 

browser

 

upgrade

 

(HTTP/

 

HTTPs)

 

and

 

TFTP

 

 

Upgrade

 

through

 

console

 

port

 

as

 

well

 

NTP

 

Network

 

Time

 

Protocol

 

(NTP)

 

is

 

a

 

networking

 

protocol

 

for

 

clock

 

synchronization

 

between

 

computer

 

systems

 

over

 

packet

switched

 

networks

 

Other

 

Management

 

 

HTTP/HTTPs;

 

SSH

 

 

DHCP

 

Client/

 

DHCPv6

 

Client

 

 

Cable

 

Diagnostics

 

 

Ping

 

/

  

Traceroute

 

 

Syslog

 

 

Telnet

 

Client

 

 

IPv6

 

Management

 

Switch

 

Architecture

 

The

 

switch

 

performs

 

a

 

wire

speed,

 

non

blocking

 

switching

 

fabric.

 

This

 

allows

 

wire

speed

 

transport

 

of

 

multiple

 

packets

 

at

 

low

 

latency

 

on

 

all

 

ports

 

simultaneously.

 

The

 

switch

 

also

 

features

 

full

duplex

 

capability

 

on

 

all

 

ports,

 

which

 

effectively

 

doubles

 

the

 

bandwidth

 

of

 

each

 

connection.

 

This

 

switch

 

uses

 

store

and

forward

 

technology

 

to

 

ensure

 

maximum

 

data

 

integrity.

 

With

 

this

 

technology,

 

the

 

entire

 

packet

 

must

 

be

 

received

 

into

 

a

 

buffer

 

and

 

checked

 

for

 

validity

 

before

 

being

 

forwarded.

 

This

 

prevents

 

errors

 

from

 

being

 

propagated

 

throughout

 

the

 

network.

 

Network

 

Management

 

Options

 

The

 

switch

 

can

 

be

 

managed

 

over

 

the

 

network

 

with

 

a

 

web

 

browser

 

or

 

Telnet

 

application.

 

The

 

switch

 

includes

 

a

 

built

in

 

network

 

management

 

agent

 

that

 

allows

 

it

 

to

 

be

 

managed

 

in

band

 

using

 

SNMP

 

or

 

RMON

 

(Groups

 

1,

 

2,

 

3,

 

9)

 

protocols.

 

Содержание SM24DPB

Страница 1: ...orks SM24DPB Install Guide 33681 Rev B https www transition com Page 1 of 24 SM24DPB Managed Layer 2 Gigabit Ethernet Switch 20 100 1000Base X SFP Slots 4 100 1000Base X SFP RJ 45 Combo Ports Install Guide 33681 Rev B ...

Страница 2: ...f data or damage the system or equipment SM24DPB Managed Fiber Switch Install Guide TN PN 33681 Rev B Record of Revisions Rev Date Description of Changes A 6 3 16 Initial release for software v6 46 B 8 14 18 Update for FW v6 54 2925 update EMC and contact information Trademark notice All trademarks and registered trademarks are the property of their respective owners All other products or service ...

Страница 3: ...quired to correct the interference at his own expense You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or better for 10 Mbps connections Category 5 or better for 100 Mbps connections Category 5 5e or 6 for 1000 Mbp...

Страница 4: ... between outdoor device and this device Addition of an arrester between outdoor device and this switch NOTE The switch is indoor device if it will be used in outdoor environment or connects with some outdoor device then it must use a lightning arrester to protect the switch WARNING Self demolition on Product is strictly prohibited Damage caused by self demolition will be charged for repairing fees...

Страница 5: ...ility robust security and QoS AC DC Dual Power Supply DHCP Server APR Auto Power Reset IPv4 IPv6 L3 static route IEEE 802 3az EEE Energy Efficient Ethernet standard for green Ethernet DMS Device Management System Benefits With the APR feature enabled the switch automatically pings the device and if the device fails the switch toggles the PoE power automatically resetting the device Auto Power Rese...

Страница 6: ...mensions WxHxD Weight Operating Humidity 442 x 44 x 211 Millimeters 17 4 x 1 73 x 8 31 Inches 3 1 Kilograms 6 8 Pounds 10 to 90 non condensing Voltage and Frequency Input Voltage and Frequency AC Voltage 100 240 VAC AC Frequency 50 60 Hz DC Voltage 24 72 VDC Certifications Electromagnetic Emissions EMC CE FCC Part 15 Class A Software Features Layer 2 Switching Spanning Tree Protocol STP Standard S...

Страница 7: ...g MD5 hash guest VLAN single multiple host mode and single multiple sessions Supports IGMP RADIUS based 802 1X Dynamic VLAN assignment Layer 2 Isolation Private VLAN Edge PVE also known as protected ports provides L2 isolation between clients in the same VLAN Supports multiple uplinks Port Security Locks MAC addresses to ports and limits the number of learned MAC address IP Source Guard Prevents i...

Страница 8: ...vice configuration CLI Command Line Interface For users to configure manage switches in command line modes Dual Image Independent primary and secondary images for backup while upgrading SNMP SNMP version1 2c and 3 with support for traps and SNMP version 3 user based security model USM Firmware Upgrade Web browser upgrade HTTP HTTPs and TFTP Upgrade through console port as well NTP Network Time Pro...

Страница 9: ...3x auto negotiation of flow control so the optimum data rate and transmission can be selected automatically SFP Transceiver Slots The switch supports the Small Form Factor Pluggable SFP transceiver slots port 1 to port 24 ports 21 to 24 are shared with RJ 45 ports 21 24 are combo interface RJ45 SFP In the default configuration if an SFP transceiver purchased separately is installed in a slot and h...

Страница 10: ...Link Act Speed Condition Green Amber Status Blinks when any traffic is present The light is green when linking up 10 1000Mbps The light is Amber when linking up 100Mbps System LED PWR AC Condition Green Status Lights when power on from AC source System LED PWR DC Condition Green Status Lights when power on from DC source System LED SYS Condition Green Status Blinking when system is booting lit whe...

Страница 11: ...d Contact your sales representative if any items are missing or damaged Save the packaging for possible future use Selecting a Site The Switch can be mounted in a standard 19 inch equipment rack via Rack mount Kit Be sure to follow the guidelines below when choosing a location The site should Be at the center of all the devices you want to link and near a power outlet Be able to maintain its tempe...

Страница 12: ...r shielded twisted pair STP cable with RJ 45 connectors Category 5 or Category 5e with maximum length of 100 meters is recommend 100BASE TX and Category 5e or 6 with maximum length of 100 meters is recommend for 1000BASE T Protection from radio frequency interference emissions Electrical surge suppression Separation of electrical wires and data based network wiring Safe connections with no damaged...

Страница 13: ...ture range 20 to 60 C Mechanical Loading Do not place any equipment on top of a rack mounted unit Circuit Overloading Be sure that the supply circuit to the rack assembly is not overloaded Grounding Rack mounted equipment should be properly grounded Step 1 Attach the brackets to the device using the screws provided in the Mounting Accessory Step 2 Mount the device in the rack via Rack Mount kit us...

Страница 14: ...he first switch Step 2 Set the device on a flat surface near an AC power source making sure there are at least two inches of space on all sides for proper air flow Step 3 If installing a single switch only go to Connecting to Power on page 15 Step 4 If installing multiple switches attach four adhesive feet to each one Place each device squarely on top of the one below in any order ...

Страница 15: ...nector facing down Note that SFP transceivers are keyed so they can only be installed in one orientation Step3 Slide the SFP transceiver into the slot until it clicks into place Connecting to Power Make cable connections before connecting Power Connecting to AC Power Source You can plug or remove an AC power cord through the AC socket from AC power source Step 1 Insert the AC power cord directly i...

Страница 16: ...optic cable The lasers are inherently eye safe in normal operation However user should never look directly at a transmit port when it is powered on WARNING When selecting a fiber SFP device considering safety please make sure that it can function at a temperature that is not less than the recommended maximum operational temperature of the product You must also use an approved Laser SFP transceiver...

Страница 17: ... switch corresponding to the port to be sure that the connection is valid The fiber optic ports operate at 1 Gbps The maximum length for fiber optic cable operating at Gigabit speed will depend on the fiber type as listed under 1000 Mbps Gigabit Ethernet Collision Domain Connectivity Rules When adding hubs to your network please note that because switches break up the path for connected devices in...

Страница 18: ...rt configuration A port on your Switch may not be operating as you expect because it has been put into a blocking state by Spanning Tree GVRP automatic VLANs or LACP automatic trunking Note that the normal operation of the Spanning Tree GVRP and LACP features may put the port in a blocking state Or the port just may have been configured as disabled through software 6 SYS LED is Off Check connectio...

Страница 19: ...n Networks makes available are 25105 Mean Well SDR 120 48 25131 MEANWELL SDR 75 48 Industrial Power Supply 25104 Mean Well SDR 240 48 INPUT 100 240VAC 2 6A 50 60 Hz OUTPUT 48V 5A Use copper wire only Maximum surrounding air temperature 60 C Instructions for installation in a pollution degree 2 environment Terminal Torque 7 Lb in DC connections at top of PS Terminal Torque 4 4 Lb in AC connections ...

Страница 20: ...120mVp p Voltage Range 48 55VDC Voltage Tolerance 1 0 Line Regulation 0 5 Load Regulation 1 0 Input Voltage Range Switch Selectable 88 264VAC 124 370VDC Frequency Range 47 63Hz Efficiency 90 Protection Overload 110 150 Overvoltage 56 65 8V Dimensions Width 1 26 32 mm x Depth 4 02 102 mm x Height 4 93 125 2 mm Environment Operating 30 C to 70 C Storage 40 C to 85 C Humidity 20 to 95 non condensing ...

Страница 21: ...Transition Networks SM24DPB Install Guide 33681 Rev B https www transition com Page 21 of 24 DC Power Supply Wiring Declaration of Conformity ...

Страница 22: ...oltage failures caused by use outside of the product s specified rating or normal wear and tear of mechanical components Transition Networks will at its option Repair the defective product to functional specification at no charge Replace the product with an equivalent functional product Refund a portion of purchase price based on a depreciated value To return a defective product for warranty cover...

Страница 23: ...d to the customer for authorization of repair If no authorization is obtained or the product is deemed not repairable Transition Networks will retain the 200 00 service charge and return the product to the customer not repaired Non warranted products that are repaired by Transition Networks for a fee will carry a 180 day limited warranty All warranty claims are subject to the restrictions and conv...

Страница 24: ...w transition com Page 24 of 24 Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 USA Tel 952 941 7600 or 1 800 526 9267 Fax 952 941 2322 Copyright 2016 2018 Transition Networks All rights reserved SM24DPB Managed Fiber Switch Install Guide 33681 Rev B ...