24-Hour Technical Support:  1-800-260-1312 -- International:  00-1-952-941-7600

Installation 

CAUTION: Wear a grounding device and observe electrostatic discharge precautions
when handling the media converter. Failure to observe this caution could result in
damage to, and subsequent failure of, the media converter slide-in-module.

Six-position switch 140 and 180 models

The 140/180 six-position switch is located on the circuit board of the media
converter. Use a small, flat-blade screwdriver

(or a similar device) 

to set the

switches according to the site requirements 

(see the drawing below for the 140)

TP 

S

pee

d

:  UP = 100 Mb

s

, DOW

N

 = 10 Mb

s

  

   (Note 1)

TP Au

t

o-

N

e

g

o

t

ia

t

ion:  UP = Enable

d

, DOW

N

 = Di

s

able

d

TP Duplex:  UP = Full, DOW

N

 = Hal

f

 

   (Note 1)

Po

rt

 2/3 Re

d

un

d

ancy  UP = Di

s

able

d

, DOW

N

 = Enable

d

Reve

rt

 wi

t

S

W4 

d

own:  UP = Di

s

able

d

, DOW

N

 = Enable

d

S

W Po

s

i

t

ion Up

Model 140

S

W Po

s

i

t

ion  Down

P2/P3 Blockin

g

 UP = Di

s

able

d

, DOW

N

 = Enable 

1 2 3 4 5 6

1.   Twisted-Pair Auto-Negotiation

UP

Enable Auto-Negotiation for the copper connection.

DOWN Disable Auto-Negotiation for the copper connection.

2.   Twisted-Pair Speed 10Mbs/100Mbs 

(See Note 1)

UP

Set copper connection speed to 100Mbs.

DOWN Set copper connection speed to 10Mbs. 

3. 

Twisted-Pair Full/Half Duplex 

(See Note 1)

UP

Operate in full-duplex mode. 

DOWN Operate in half-duplex mode of the attached device.

4.   Redundancy

(Ports 2 and 3) 

UP

Disabled 

DOWN Enabled

5.  Primary/Secondary revert with SW4 DOWN

UP

Disabled 

(continues to use the secondary port after primary port has 

been restored) 

recommended setting

DOWN Enabled 

(reverts to the primary port after it has been restored)

6.

Port 2 to Port 3 Blocking
UP Disabled
Down

Enabled

Note 1:  

Only use when Auto-Negotiation is disabled.

SGFEBxx40-1xx

[email protected] -- Click the “Transition Now” link for a live Web chat.

3

Installation—continued

Po

rt

 1 Duplex:  UP = Full, DOW

N

 = Hal

f

 

(note 3)

Po

rt

 1 

S

pee

d

:  UP = 1000 Mb

s

, DOW

N

 = 100 Mb

s

 

(note 2)

Po

rt

 1 Mo

d

e:  UP = 100/1000Ba

s

e-X,  DOW

N

 = 

SG

MII

Po

rts

 2/3 Re

d

un

d

ancy:  UP = Di

s

able

d

, DOW

N

 = Enable

d

S

W Po

s

i

t

ion Up

Model 180

S

W Po

s

i

t

ion  Down

1 2 3 4 5 6

Reve

rt

 wi

t

S

W4 

d

own :  UP = Di

s

able

d

, DOW

N

 = Enable

d

P2/P3 Blockin

g

 UP = Di

s

able

d

, DOW

N

 = Enable 

Note 2:  

Only use if in 100/1000Base-X mode, SW3 UP.

Note 3:  

Only use if in 100/1000Base-X mode and in 100 Mbs mode, SW3 UP;
SW1 DOWN

1.   Speed 

(Port 1)  (See Note 2)

UP

1000 Mbs

DOWN 100 Mbs

2.  Duplex

(Port 1) (See Note 3)

UP

Full

DOWN Half 

3.  Mode 

(Port 1)

UP 100/1000Base-X. 
DOWN SGMII 

( Port 1 copper. model 140 only)

4.   Redundancy 

(Ports 2 and 3)

UP

Disabled 

DOWN Enabled

5.  Primary/Secondary revert with SW4 DOWN

UP

Disabled 

(continues to use the secondary port after primary port has 

been restored) 

recommended setting

DOWN Enabled 

(reverts to the primary port after it has been restored)

6.

Port 2 to Port 3 Blocking
UP Disabled
Down

Enabled

Содержание SGFEB1040-140

Страница 1: ...SFP 1000Base X SGFEB4040 180 Chassis Card Media Converter Three SFP Ports 100 1000Base X SFPs to 1000Base X SFPs Transition Networks SGFEB1040 140 series media converters have three SFP ports and are...

Страница 2: ...perate in half duplex mode of the attached device 4 Redundancy Ports 2 and 3 UP Disabled DOWN Enabled 5 Primary Secondary revert with SW4 DOWN UP Disabled continues to use the secondary port after pri...

Страница 3: ...Transition Now link for a live Web chat 5 Installation continued Installing the RJ 45 copper cable model 140 only Port 1 10 100 1000Base T Copper Port 1 Locate a 10 100 1000Base TX compliant copper ca...

Страница 4: ...located next to the fiber port Port 2 PWR Power ON Green connection to external AC power LK1 LK2 LK3 Link Activity ON Green A link has been established for the fiber connection Flashing The fiber conn...

Страница 5: ...d SW5 down These configurations are set by the user Far End Fault signal is sent Media Converter A Media Converter B Near End Device Far End Device original fault on the fiber link media converter B d...

Страница 6: ...USB RS232 RS422 RS485 DS1 DS3 Video Coax etc are NOT to be connected to inter building outside plant link segments that are subject to lightening transients or power faults techsupport transition com...

Страница 7: ...rect mode disconnect and reconnect the fiber cable to restart the initialization process Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 13 techsupport transition com Click the Transition...

Страница 8: ...kennung ihrer Konformit t Compliance Information CISPR EN55022 Class A EN55024 EN61000 FCC Class A CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a Clas...

Страница 9: ...tive owners Copyright Restrictions 2003 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without...

Отзывы: