2
SBFTF10xx-11x
Tech Support:
1-800-260-1312
International:
00-1-952-941-7600
(24 hours)
*
Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network. (TX) = transmit (RX) = receive
** SBFTF1029
-110
and
-111
are intended to be installed in the same network
where one is the local converter and the other is the remote converter.
*** SBFTF1029
-112
and
-113
are intended to be installed in the same network
where one is the local converter and the other is the remote converter.
Installation
Copper and Fiber Ports
The figure below illustrates the locations of the two (2) twisted-pair copper ports
and the one (1) fiber port.
Part Number
Copper -
two (2) ports
10Base-T/100Base-TX
Fiber-Optic -
one (1) ports
Single Fiber
SBFTF1029-110
RJ-45
100 m (328 ft)*
SC, 1310 nm (TX)/1550 nm (RX)
single mode, 20 km (12.4 miles
SBFTF1029-111
RJ-45
100 m (328 ft)*
SC, 1550 nm (TX)/1310 nm (RX)
single mode, 20 km (12.4 miles)*
SBFTF1029-112
RJ-45
100 m (328 ft)*
SC, 1310 nm (TX)/1550 nm (RX)
single mode, 40 km (24.8 miles)*
SBFTF1029-113
RJ-45
100 m (328 ft)*
SC, 1550 nm (TX)/1310 nm (RX)
single mode, 40 km (24.8 miles)*
10/100TX
FD
LACT
PWR
10/100TX
100Base-FX
Twisted-Pair
Port 1 (TP1)
Twisted-Pair
Port 2 (TP2)
Fiber Port 1 (F1)
The
chassis
version
of the media converter is CBFTF10xx-11x. For more
information, see the CBFTF10xx-11x
u
ser’s
g
uide on-line at:
www.transition.com.
Installation
-- Continued
Set the Dip Switches
The dip switches are located on the side of the media converter. Use a small,
flat-blade screwdriver or a similar device to set each dip switch.
“SW1” switches 1 - 6
Dip switches 1, 2, and 3 apply only to twisted-pair copper port 1 (TP1).
Dip switch 4 applies to fiber port 1 (F1).
Dip switches 5 and 6 apply to both twisted-pair copper ports (TP1 and TP2).
“Config. Switches” 1 - 4
Dip switches 1, 2, 3, and 4 apply
only
to twisted-pair copper port 2 (TP2).
NOTE:
Switches 1, 2, and 3 apply
only
to twisted-pair
copper port 1 (TP1)
.
-- Click the
“Transition Now”
link for a live Web chat.
3
1. Twisted-Pair Auto-Negotiation
UP (Enabled)
- The media converter “advertises”
ALL rate and mode capabilities to the network:
• 100Mb/s full-duplex • 100Mb/s half-duplex,
• 10Mb/s full-duplex • 10Mb/s half-duplex.
DOWN (Disabled)
- The bridging media converter
does not “advertise” the rate and mode capabilities
to the network.
Switches 2
and
3
are then used to
set the twisted-pair rate and mode.
2. Twisted-Pair Rate
UP (100Base-TX)
- Sets the twisted-pair rate to
100Base-TX.
DOWN (10Base-T)
- Sets the twisted-pair rate to
10Base-T.
3. Twisted-Pair Mode
UP (Full-Duplex)
- The twisted-pair cable distances
are constrained by the cable requirements (see
pages 1 and 2).
DOWN (Half-Duplex):
- The twisted-pair cable
distances are constrained by the 512-Bit Rule (see
page 9).
DOWN
1
UP
2
Twisted-Pair Auto-Negotiation ON
Twisted-Pair Auto-Negotiation OFF
Twisted-pair 100Base-TX
Twisted-pair 10Base-T
DOWN
UP
2
Twisted-pair Full-Duplex
Twisted-pair Half-Duplex
DOWN
UP
3