Transition Networks RS232-CF-01 Скачать руководство пользователя страница 2

RS232-CF-01 IN THE NETWORK

The RS232-CF-01 can be used to install a fiber network extension between
DTEs or between a DTE and a DCE.

A straight-through cable configuration is required for installation between DTEs.
A null modem cable configuration is required for installation between a DTE
and a DCE. (See page 6.)

TECHNICAL SPECIFICATIONS

Standards

TIA/EIA-574

Data Rate

1200-115,000 bits per second

Optical Loss Budget

ª10dB

Case Dimensions

5.7" x 3.0" x 1.8"

(145mm x 76mm x 46mm)

Shipping Weight

3 pounds

(1.4 kilograms)

Environment

Temperature:

0-50°C (32° to 122° F )

Humidity

10-90%, non condensing 

Altitude

0-10,000 feet

Power Supply Requirements

Replace power supply with only the equivalent input

rating (see below) and output rating (regulated 9VDC at 500 mA).

TN PN

Requirement

Location

3517

240 volts, 50 hertz

United Kingdom

3516

230 volts, 50 hertz

Europe

3518

120 volts, 60 hertz

USA/Canada/Mexico

3514

100 volts, 50-60 hertz

Japan

3515

240 volts, 50 hertz

Australia

Power Consumption

<100mA

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

RS232-CF-01Series Serial-Port Extension Media Converters

Part Number(s):

RS232-CF-01, RS232-CF-01(SM)

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the RS232-CF-01 to which this declaration refers is in

conformity with the following standards.

EMC-CISPR 22: 1985 Class A;  EN 55022: 1988 Class A;  EN 50082-1:1992;
EN 60950 A4:1997;  IEC 801.2, IEC 801.3, and IEC 801.4;  IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_July 1, 1999_____

Stephen Anderson, Vice-President of Engineering

Date

RS-232 STRAIGHT THROUGH

CONFIGURATION CABLE

RS-232 STRAIGHT THROUGH

CONFIGURATION CABLE

DTE

DTE

NOTE: SHIELDED CABLES REQUIRED ON DB-9 FOR

EMC COMPLIANCE.

Отзывы: