background image

Transition Networks 

 

PS-DC-DUAL-5624T Power Supply Install Guide 

33788 Rev. D 

                             

https://www.transition.com

  

Page 

16

 of 

18

 

Electrical Safety Warnings  

Electrical Safety 

IMPORTANT

: This equipment must be installed in accordance with safety precautions. 

Elektrische Sicherheit 

WICHTIG

: Für die Installation dieses Gerätes ist die Einhaltung von Sicherheitsvorkehrungen erforderlich. 

Elektrisk sikkerhed 

VIGTIGT

: Dette udstyr skal installeres i overensstemmelse med sikkerhedsadvarslerne. 

Elektrische veiligheid 

BELANGRIJK

: Dit apparaat moet in overeenstemming met de veiligheidsvoorschriften worden geïnstalleerd. 

Sécurité électrique 

IMPORTANT

: Cet équipement doit être utilisé conformément aux instructions de sécurité. 

Sähköturvallisuus 

TÄRKEÄÄ

: Tämä laite on asennettava turvaohjeiden mukaisesti. 

Sicurezza elettrica 

IMPORTANTE

: questa apparecchiatura deve essere installata rispettando le norme di sicurezza. 

Elektrisk sikkerhet 

VIKTIG

: Dette utstyret skal installeres i samsvar med sikkerhetsregler. 

Segurança eléctrica 

IMPORTANTE

: Este equipamento tem que ser instalado segundo as medidas de precaução de segurança. 

Seguridad eléctrica 

IMPORTANTE

: La instalación de este equipo deberá llevarse a cabo cumpliendo con las precauciones de seguridad. 

Elsäkerhet 

OBS!

 Alla nödvändiga försiktighetsåtgärder måste vidtas när denna utrustning används. 

Warranty 

Five-Year Limited Hardware Warranty 

Transition Networks warrants to the original consumer or purchaser that each of its PS-DC-DUAL-5624T products and all 
components thereof, will be free from defects in material and/or workmanship for a period of five years from the original factory 
shipment date. Any warranty hereunder is extended to the original consumer or purchaser and is not assignable. Transition 
Networks makes no express or implied warranties including, but not limited to, any implied warranty of merchantability or fitness 
for a particular purpose, except as expressly set forth in this warranty. In no event shall Transition Networks be liable for incidental 
or consequential damages, costs, or expenses arising out of or in connection with the performance of the product delivered 
hereunder. Transition Networks will in no case cover damages arising out of the product being used in a negligent fashion or 
manner. 
This warranty does not cover damage from accident, acts of God, neglect, contamination, misuse or abnormal conditions of 
operation or handling, including over-voltage failures caused by use outside of the product’s specified rating, or normal wear and 
tear of mechanical components. 
Transition Networks will, at its option: 
•Repair the defective product to functional specification at no charge 
•Replace the product with an equivalent functional product 
•Refund a portion of purchase price based on a depreciated value 
To return a defective product for warranty coverage, contact Transition Networks’ Customer Support for a return authorization 
number. 
Send the defective product postage and insurance prepaid to the following address: 

Содержание PS-DC-DUAL-5624T

Страница 1: ...nting 12 Grounding 12 Connecting POWER OUTPUT 12 Connecting AC INPUT 12 PWR Power LED 13 Fuse Replacement 13 Installing TN 16210 Ferrite 13 Related Manuals 14 For More Information 14 Application Example 14 3 Related Information 15 Troubleshooting 15 Compliance Information 15 Electrical Safety Warnings 16 Warranty 16 Product Label and Box Label 17 Contact Us 18 Record of Revisions 18 1 Introduction...

Страница 2: ... Cord Right angle Features Wide 100 240VAC input with externally accessible fuse 56 VDC output provides plenty of margin for the powered device PD to meet minimum PSE output voltage requirements o IEEE 802 3af 44VDC 12V margin o IEEE 802 3at 50VDC 6V margin o IEEE 802 3bt 52VDC 4V margin Desktop mountable DIN rail form factor Full compliance with the IEEE 2250 VDC PoE isolation requirements Active...

Страница 3: ...nput Frequency Range 47 63 HZ Power Consumption 4 0A at 120VAC typical Dimensions HxWxD Width 6 25 159 mm x Depth 6 45 164 mm x Height 1 75 44 mm Weight 1 8 lbs 0 72Kg Environment Operating Temp 20 C to 70 C restricted 20 C to 50 C unrestricted Storage Temp 30 C to 70 C Operating Humidity 5 to 95 non condensing Alarm output rating 30VDC maximum 50mA maximum MTBF 623 377 hrs ENV GB TEMP 30 00 deg C...

Страница 4: ...ttps www transition com Page 4 of 18 Power Cord Specifications Power cord specifications are provided below 27275 AC Power Cord with locking NA Line Cord Right angle Connectors NEMA 5 15P IEC 60320 C13 Length 3 ft 0 91 m Gauge 18 Jacket Type SJTW 105 C Rating 10A 125V Safety UL ...

Страница 5: ...Transition Networks PS DC DUAL 5624T Power Supply Install Guide 33788 Rev D https www transition com Page 5 of 18 27274 AC Power Cord with locking NA Line Cord ...

Страница 6: ...Transition Networks PS DC DUAL 5624T Power Supply Install Guide 33788 Rev D https www transition com Page 6 of 18 3344 AC Power Cord non locking NA Line Cord ...

Страница 7: ...nk Will cycle through if one or more events alarms occur with one of these Blink Rates 1 blink per 3 seconds Fan locked no tach 2 blinks per 3 seconds Fan less than 30 PWM Pulse Width Modulation setting 3 blinks per 3 seconds 24VDC output out of spec 4 blinks per 3 seconds Exceeding 25 Deg C 5 blinks per 3 seconds Exceeding 75 Deg C If more than one alarm is set the LED will cycle through the Blin...

Страница 8: ...ower Supply Install Guide 33788 Rev D https www transition com Page 8 of 18 Dimensions Power Cords Locking and non locking line cords are available AC Power Cord with locking NA Line Cord AC Power Cord with locking NA Line Cord Right angle ...

Страница 9: ...att Isolated Power Supply with 56VDC and 24VDC Dual Output On Off switch The power on power off switch is labeled O off on FUSE The fuse can be replaced without opening the chassis see Fuse Replacement below AC INPUT Power connection labeled 100 240VAC 50 60 Hz see Connecting AC INPUT below POWER OUTPUT Terminal Block labeled 56 VDC and ALARM and 24 VDC and See Connecting POWER OUTPUT below PWR Po...

Страница 10: ...or such High Risk Activities Notice Not Designed for Use in Life Support Equipment or Applications These products are not designed for use in life support equipment or applications that would cause a life threatening situation if any such product failed Do not use this product in these types of equipment or applications Operating Temperature RESTRICTED ACCESS LOCATION A location for equipment wher...

Страница 11: ...rating Temperature 20 to 70 C Restricted 50 60 Hz 5 5A max Output Power Power 1 56VDC 315 Watts 5 6 Amps Power 2 24VDC 30 Watts 1 25 Amps Unpacking Carefully unpack the Power Supply Verify you have received the items below Save the packaging for possible future use One Power Supply One Postcard One printed Quick Start Guide 33792 One AC Power Cord option Four Rubber Feet One Snap on Ferrite TN 162...

Страница 12: ... there is at least 2 inches of open space outside of at least one of the two vented sides See below 2 Hang the top of the DIN rail bracket on the DIN rail Caution The DIN Rail Spring Clip must be facing upwards as shown below 3 Click the bottom of the DIN rail bracket onto the DIN rail Grounding Connecting POWER OUTPUT Use 14 AWG stranded or better wire typ to connect to 56 VDC 315W Use 20 AWG str...

Страница 13: ...r temperature event is occurring Fuse Replacement The AC INPUT is 100 240VAC 50 60Hz 5 5A The Fuse is a 5x20mm 6 3A 250V SB slo blo externally accessible fuse Warning Disconnect all Power sources before servicing Caution Replace fuse with same Type Rating Installing TN 16210 Ferrite For EMC reasons install Snap on Ferrite TN 16210 over the 24 VDC PS DC DUAL 5624T output wires after installation 1 ...

Страница 14: ...nsition Networks Manuals Brochures Data Sheets etc go to the Support Library no logon required Note Information in this document is subject to change without notice Note that this manual provides links to third party web sites for which Transition Networks is not responsible Application Example The example below shows a SISPM1040 384 LRT C switch Enclosure Door sensor and PS DC DUAL 5624T power su...

Страница 15: ... UL 60950 1 With the technical construction on file at the above address this product carries the CE Mark I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standards s Place Minnetonka Minnesota Date July 29 2019 Signature Stephen Anderson Full Name Stephen Anderson Position Vice President of Engineering FCC Regulations NOTE This equipment ha...

Страница 16: ... warrants to the original consumer or purchaser that each of its PS DC DUAL 5624T products and all components thereof will be free from defects in material and or workmanship for a period of five years from the original factory shipment date Any warranty hereunder is extended to the original consumer or purchaser and is not assignable Transition Networks makes no express or implied warranties incl...

Страница 17: ...and all customs charges tariffs or and taxes are the customer s responsibility Before making any non warranty repair Transition Networks requires a 200 00 charge plus actual shipping costs to and from the customer If the repair is greater than 200 00 an estimate is issued to the customer for authorization of repair If no authorization is obtained or the product is deemed not repairable Transition ...

Страница 18: ...B 8 19 19 Revise specs labels and model number C 9 18 19 Add power cord information D 11 9 21 Remove PS DC DUAL 5612T references and update specifications Trademark notice All trademarks and registered trademarks are the property of their respective owners All other products or service names used in this publication are for identification purposes only and may be trademarks or registered trademark...

Отзывы: