2
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
CPSMC0200-22x
Installation
Installing a slide-in-module
CAUTION: DO NOT install Two (2) Point System media converter slide-in-modules
with a total power requirement exceeding 12 W
(with an average of 6 W per slot)
.
Failure to observe this caution could result in data losses and media converter failure.
CAUTION: Wear a grounding device and observe electrostatic discharge precautions
when installing the media converter slide-in-module into the chassis. Failure to
observe this caution could result in damage or failure of the media converter.
Note:
If only installing one slide-in-module, ensure network standards compliance by
obtaining a custom faceplate
(P/N CPSFP-200)
from Transition Networks for
installation into the second, unused slot.
To install a slide-in-module into the dual-slot chassis:
1.
Refer to the user’s guide that comes with the slide-in-module to ensure that any
switches or jumpers on the slide-in-module circuit board are set correctly for the
site installation.
2.
Carefully align the slide-in-module with the chassis installation guides and slide
the module into the installation slot.
3.
Ensure that the slide-in-module is firmly seated inside the chassis.
4.
Push in and rotate the attached panel faster screw clockwise to secure the slide-in-
module to the chassis front.
5.
Repeat steps 1-4 for the second slide-in-module.
Panel Fastener Screw
[email protected] -- Click the “Transition Now” link for a live Web chat.
3
Installation
-- Continued
Power the chassis
CAUTION:
When using two power supplies to power the chassis, one must be a power supply with
an ungrounded secondary. Using two power supplies
(with each secondary grounded
to protective earth ground)
could cause unreliable operation of the chassis and its
converters, due to installation specific Protective Ground fault conditions.
Note:
The power supply shipped with the chassis has its secondary connected to
protective earth ground. The optional power supply does not have its
secondary connected to protective earth. Do Not use two power supplies
(with
grounded secondaries)
to power the chassis.
To supply power to the dual-slot chassis using the power supply:
1.
Connect the barrel connector of the power supply
(grounded secondary)
to one of
the dual-slot chassis’ power ports
(located on the back of the chassis)
. See figure
below. If using the
(grounded secondary)
power supply only, go to step 3.
2.
Connect the barrel connector of the second power supply
(ungrounded secondary)
to the dual-slot chassis’ remaining power port.
3.
Connect the power supply plug(s) into AC power.
4.
Verify that the dual-slot chassis is powered by observing the illuminated LED(s)
on the chassis front panel. See the figure below.
Note:
If the power supply/supplies are 11VDC or above, the associated LED/LEDs
will be lit
(PS1 LED/PS2 LED).
If either power supply’s output is under the
11VDC minimum requirement that LED will not turn ON, indicating a
problem.
DC power source
To power the dual-slot chassis using the SPS1872-SA DC external power supply,
consult the SPS1872-SA user manual at Transition Networks.com.
Last Gasp Option
(CPSMC0200-221 models only)
The CPSMC0200-221 models feature the Last Gasp option, which enables the device
to send an SNMP trap in the event of a power failure, alerting the management console
that the device has failed.
P/ S 2
IN
P/S 1
IN
P/ S 1
LE D
P/ S 2
LE D
Chassis Back Panel
Chassis Front Panel