Содержание MIL-SEM24T4GPA

Страница 1: ...1 20 10 100 1000T 4 10 100 1000T RJ 45 SFP Combo Ports SNMP Lite Managed Switch MIL SEM24T4GPA User Manual Rev A2 2007 12 28...

Страница 2: ...purchaser and is not assignable Transition Networks makes no express or implied warranties including but not limited to any implied warranty of merchantability or fitness for a particular purpose exce...

Страница 3: ...in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to tr...

Страница 4: ...plication 14 Console Management 15 Connecting to the Console Port 15 Login in the Console Interface 15 CLI Management 17 Web Based Management 18 About Web based Management 18 Preparing for Web Managem...

Страница 5: ...P Status 45 Rate Limit Configuration 45 802 1X Configuration 47 802 1X Parameters 49 802 1X Statistics 49 MAC Address Table Control 50 Static MAC Address Entries in Permanent Table 51 Configuration Up...

Страница 6: ...uto sensing 10 100 1000Base TX RJ 45 ports and 4 SFP RJ 45 combo ports for higher connection speed Features System Interface Performance RJ 45 port support Auto MDI MDI X Function 4 Mini GBIC Sockets...

Страница 7: ...nk down Web GUI Firmware Update and System Configuration Restore Backup Software Feature Management SNMP v1 SNMP v2c Telnet Console Command Line Interface Web management SNMP MIB RFC 1213 MIBII RFC 14...

Страница 8: ...Support ingress packet filter and egress packet limit The egress rate control supports all of packet type and the limit rates are 1K 32Mbps Ingress filter packet type combination rules are Broadcast M...

Страница 9: ...Power Cord 1 RS 232 cable 1 User Manual 20 10 100 1000T 4 10 100 1000T Mini GBIC Four Rubber Pads Power Cord Combo SNMP Lite Managed Switch RS 232 cable User Manual Compare the contents of the MIL SEM...

Страница 10: ...are also located on the front panel of the switch Front Panel of the 20 10 100 1000T 4 10 100 1000T Mini GBIC Combo SNMP Lite Managed Switch RJ 45 Ports Auto MDI MDIX 24 10 100 1000 auto sensing for 1...

Страница 11: ...de a real time indication of systematic operation status LED Status Description Green Power On Power Off No power input 1000 Green The port is operating at the speed of 1000Mbps Green The port is succ...

Страница 12: ...l of the MIL SEM24T4GPA Switch as shown in figure The Switches will work with AC in the range 100 240V AC 50 60Hz Rear Panel of the MIL SEM24T4GPA Switch Desktop Installation Set the switch on a suffi...

Страница 13: ...om of the Switch These footpads can prevent the Switch from shock vibration Power On Connect the power cord to the power socket on the rear panel of the Switch The other side of power cord connects to...

Страница 14: ...tworks where large data broadcast are constantly processed this switch is suitable for department user to connect to the corporate backbone User can connect PCs workstations and servers to each other...

Страница 15: ...program Connecting the switch to a terminal via RS 232 cable Login in the Console Interface When the connection between Switch and PC is ready turn on the PC and run a terminal emulation program or H...

Страница 16: ...cation parameters After finishing the parameter settings click OK When the blank screen shows up type in root then press enter button to get into command line mode Please see below figure for login sc...

Страница 17: ...17 CLI Management The system supports console management CLI command After you login to the system you will see a command prompt CLI command interface...

Страница 18: ...applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen NOTE By default IE5 0 or later version does not allow Java Applets to activ...

Страница 19: ...Mask 255 255 255 0 Default Gateway 192 168 1 254 Password root Login Interface System Configuration System parameters information list as below and the other parameters of system can be configured as...

Страница 20: ...e Left the DHCP lease time After 50 of the lease time has passed the client switch will attempt to renew the lease with the original DHCP server that it obtained the lease from using a DHCPREQUEST mes...

Страница 21: ...te Management Security in fact it gives the permission to access the switch only when the port of VLAN group ID is equal to the Management VLAN ID Name the name of the switch Password Web GUI login pa...

Страница 22: ...ion speed Auto Negotiation Displays the negotiation status of the port Flows Control Displays the status of flow control MaxFrame 1518 9600 Displays the Maximum Frame Size Drop frames after excessive...

Страница 23: ...23 Port Status interface Statistics Overview for all ports The following information provides the current port statistics Press Clear button to clean all counts...

Страница 24: ...trol and maximum frame size of the ports by this page Link Displays the current connection speed Mode Displays the negotiation status of the port Flows Control Select the operating mode Auto Speed 10...

Страница 25: ...Refresh to get the newest status Port Configuration interface Aggregation Trunking Configuration Port trunk allows multiple links to be bundled together and act as a single physical link for increased...

Страница 26: ...y before you apply it When a proper hash algorithm is used traffic is kind of randomly decided to be transmitted across either link within the trunk and load balancing will be seen Grouping the member...

Страница 27: ...LAN VLAN is a logical network grouping that limits the broadcast domain which would allow user to isolate network traffic and therefore only the members of VLAN will receive traffic from the members...

Страница 28: ...nd the Vlan Entry And then click Apply to bring up the configuration interface as below VLAN Setting interface VLAN Port Setting Change to the VLAN Port Setting tab for adjusting the VID Setting PVID...

Страница 29: ...29 Tagged Outgoing frames with VLAN Tagged After that click Apply to apply the configuration Or click Refresh to reset the configuration before applying VLAN Port Setting interface...

Страница 30: ...ion and reception functions in an orderly manner Link aggregation lets user group up to eight consecutive ports into a single dedicated connection This feature can expand bandwidth to a device on the...

Страница 31: ...ACP status information will display as below Protocol Active Displays whether the LACP protocol is active Partner Port Number Displays the partner port number which is connecting to this port Operatio...

Страница 32: ...32 LACP Status interface...

Страница 33: ...changed user has to reboot the switch The value must be multiple of 4096 according to the protocol standard rule Hello Time 1 10 The scale of 1 10 sec will be set as a period of time that how often th...

Страница 34: ...face RSTP Port Configuration Protocol Enable to enable or disable the port protocol Edge The port directly connected to end stations cannot create bridging loop in the network To configure the port as...

Страница 35: ...me in seconds that how often the switch broadcasts hello messages to other switches Max Age Displays the number of seconds which determines the amount of time that protocol information received on a p...

Страница 36: ...d by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administr...

Страница 37: ...odes servers workstations routers switches and hubs etc on an IP network SNMP enables network administrators to manage network performance find and solve network problems and plan for network growth N...

Страница 38: ...string Enables requests accompanied by this string to display MIB object information SNMP Write Community Read Write Enables requests accompanied by this string to display MIB object information and...

Страница 39: ...um or high And then click Apply to apply the configuration Or click Refresh to reset the configuration before applying QoS Configuration interface QoS DSCP Mapping Change to Qos DSCP Mapping tab DSCP...

Страница 40: ...y high and then the packet priority will have highest priority Priority Select the priority level high medium low or normal And then click Apply to apply the configuration Or Click Refesh to reset the...

Страница 41: ...ise you can check the Weighted Round Robin WRR radio button for the queue service to be served in compliance with WRR Priority Queue Service interface And then click Apply to apply the configuration O...

Страница 42: ...lection item from Vlan Tag 0 to Vlan Tag 7 of each port to assign the priority There are 4 priority selections low normal medium and high QoS VLAN Tag Priority Mapping interface Filter Source IP Filte...

Страница 43: ...P address manually IP Mask When Mode is set in Static mode user has to assign the IP mask manually DHCP Server Allowed Mark this check box for DHCP Server allowed And then click Apply to apply the con...

Страница 44: ...IPMC Flooding enabled The default state is checked to enable the unregistered IP MultiCast flooding IGMP Snooping Enabled Mark the check box for enabling IGMP Snooping function IGMP Querying Enabled M...

Страница 45: ...MP Rate Assign the rate of transmitting packets of ICMP The rates are in the range of 1K 32768K bps or No limit Learn Frames Rate Assign the rate of learning frames The rates are in the range of 1K 32...

Страница 46: ...he range of 128K 3968K bps or No limit Shaper Assign the shaper rates in the range of 128K 3968K bps or No limit And then click Apply to apply the configuration Or Click Refesh to reset the configurat...

Страница 47: ...sed on the Radius Server Admin State Select the state of port Force Authorized The specified port is required to be held in the unauthorized state Force Unauthorized The specified port is required to...

Страница 48: ...48 802 1X Configuration interface...

Страница 49: ...ch clients connected must be re authenticated EPA Timeout 1 255 seconds Set the period of time the switch waits for a supplicant response to an EAP request And then click Apply to apply the configurat...

Страница 50: ...ss table MAC Address The MAC address of the entry Port Displays the port number from which the MAC address was learned VLAN ID Displays the VLAN ID of the port Type Displays the information of the MAC...

Страница 51: ...51 Dump MAC Address Table interface Static MAC Address Entries in Permanent Table This page displays the static MAC address information Click Refesh to get the newest information...

Страница 52: ...rrent configuration as a file by clicking Download button Or you can restore the configuration from an existing file by clicking Upload button Configuration Upload Download interface Factory Default R...

Страница 53: ...are update function which allow user to update the switch firmware Click to locate the firmware And then press Upload to update the firmware Firmware Upload interface Reboot Reboot the switch in softw...

Страница 54: ...p and restore the switch configuration Click Browse to locate the file And then press Upload to upload the file For restoring the file press Download to restore the file Configuration File Transfer in...

Страница 55: ...55 Logout interface...

Страница 56: ...and fiber module should match Faulty or loose cables Look for loose or obviously faulty connections If they appear to be OK make sure the connections are snug If that does not correct the problem try...

Страница 57: ...path at any time Data path loops will cause broadcast storms that will severely impact your network performance Diagnosing LED Indicators The Switch can be easily monitored through panel indicators wh...

Страница 58: ...col IEEE802 1w Rapid spanning tree IEEE802 1p Class of service IEEE802 1Q VLAN Tagging IEEE 802 1x User Authentication RADIUS Protocol CSMA CD LED Indicators System Power Green Gigabit Copper port Lin...

Страница 59: ...function Storage Temp 40 70 95 RH Operating Humidity 10 95 Non condensing Operational Temp 0 45 Power Supply AC 100 240V 50 60Hz Power Consumption 17 9 Watts Maximum Ventilation 1 Fan for ventilating...