Troubleshooting 

If the media converter fails, isolate and correct the fault by answering the following questions and then taking the 
indicated action: 

1. Is the PWR (power) LED lit? 
 

NO 

 

• Is the power adapter the proper type of voltage and cycle frequency

 for the AC outlet? 

 

• Is the power adapter properly installed in the media converter and in the outlet?

 

 

• Contact Tech Support

. See 

Contact Us

 below. 

 

YES 

 

• Proceed to step 2.

 

2. Is the RXC (copper link) LED lit? 
 

NO 

 

• Check the 

twisted-pair copper cables for proper connection. 

 

• Contact Tech Support

. See 

Contact Us

 below. 

 

YES 

 

• Proceed to step 3.

 

3. Is the LKF (fiber link) LED lit? 
 

NO 

 

• Check the fiber cables for proper connection.

 

 

• Verify that the TX and RX cables on the 

media converter are connected to the RX and TX ports,  

 

  

   respectively, on the other device. 

• If the media converter is connected to another 

M/GE-xSW-SFP-01-xx-UxX Series using fiber, verify the  

   fiber cables and connection. 

 

• Contact Tech 

Support. See 

Contact Us

 below. 

 

YES 

 

• Proceed to step 4.

 

4. Is the RXC (copper receive) LED flashing? 
 

NO 

 

• If there is activity on the 1000Base

-T port, disconnect and reconnect the twisted-pair copper cable to  

   restart the initialization process. 

 

 Contact Tech Support. See 

Contact Us

 below. 

 

YES 

 

• Contact Tech Support

. See 

Contact Us

 below. 

5. Are the converters paired properly? Se

Ordering Information

 on page 

2

. 

6. Is the proper copper cable installed and connected correctly? Se

2. Installation 

on pag

7

. 

7. Is the proper fiber cable installed and connected correctly? See 

Front Panel Copper and Fiber Ports

 on pag

7

. 

Содержание M/GE-ISW-SFP-01-PD-URX

Страница 1: ...owered Hardened Grade converters available Contents 1 Introduction 2 Feature Benefits 2 Ordering Information 2 Family Portrait 4 Applications 4 Application Examples 5 Package Contents and Unpacking 6...

Страница 2: ...hysically secure one way communication channel between a secure network and an unsecure network These devices can be used to allow data from a classified high security area to be transmitted to a low...

Страница 3: ...ctional Transmitting Converter M GE ISW SFP 01 PD URX PoE Powered Hardened Mini 10 100 1000Base T RJ 45 to 100 1000Base X Open SFP Slot Uni directional Receiving Converter Power Supply Options SPS 246...

Страница 4: ...below shows the six available SKUs in the three paired combinations Applications The M GE xSW SFP 01 xx UxX can be used in applications such as Transmit data from a classified high security area to a...

Страница 5: ...om re entering the classified network Benefits protect assets and data block access to the secure area and prevent manipulation of secure data The figure below shows a secure network that needs to be...

Страница 6: ...ponding country specific power cord add the extension to the end of the SKU for M GE PSW SFP 01 UTX xx and M GE PSU SFP 01 URX xx only NA North America LA Latin America EU Europe UK United Kingdom SA...

Страница 7: ...quipment or injury to persons See Electrical Safety Warnings on page 23 for Electrical Safety Warnings translated into multiple languages Electrostatic Discharge ESD Observe these ESD precautions when...

Страница 8: ...rter hub etc as follows Connect the male TX cable connector to the female RX port Connect the male RX cable connector to the female TX port Connecting Single strand Fiber Cable Single strand fiber cab...

Страница 9: ...lex mode is used refer to the 512 Bit Rule If full duplex mode is used the 512 Bit Rule does not apply The cable lengths are constrained by the cable requirements Perform these steps 1 Locate a 10Base...

Страница 10: ...module from its protective packaging Note Do not remove the optical bore dust plugs until directed to do so in a later procedure 2 Check the slot orientation Position the SFP device at the desired in...

Страница 11: ...the socket connector Grasp the actuator button between your thumb and index finger and carefully pull the SFP transceiver module straight out of the module slot b If the SFP transceiver module has a b...

Страница 12: ...are shown right 1 Position the DIN rail clamp to the side of the media converter as shown below 2 Position the 4 40 screw to attach the DIN rail to the media converter as shown above left 3 Insert an...

Страница 13: ...r input RJ 45 Supporting IEEE802 3af PoE PD Standard M GE ISW SFP 01 UTX and M GE ISW SFP 01 URX Power input Terminal Block Supporting 12 48 VDC and 24 36 VAC You can use your own power source or you...

Страница 14: ...dia converter operation in the network LED descriptions are as follows TP LED Blink Rate The TP LED flash rate indicates the copper network speed Pulses second Blink Rate Speed Indicated 12 pps every...

Страница 15: ...re itself automatically to achieve the best possible mode of operation over a link It broadcasts speed 10 Mb s or 100 Mb s and duplex capabilities full or half to the other device and negotiates the b...

Страница 16: ...ironment the M GE xSW SFP 01 xx UxX Series media converters extend network distances by segmenting collision domains so that the 512 Bit Rule applies separately to each collision domain In a full dupl...

Страница 17: ...and 3 6 are the two active pairs in an Ethernet network Use only dedicated wire pairs for the active pins e g blue white white blue orange white white orange etc Do not use flat or silver satin wire...

Страница 18: ...onment M GE PSW SFP 01 UxX Operating Temp 0 C to 50 C Humidity 5 to 95 non condensing Storage Temp 15 C to 65 C Altitude 0 to 10 000 ft M GE ISW SFP 01 xx UxX Operating Temp 40 C to 75 C Humidity 5 to...

Страница 19: ...t NO Check the fiber cables for proper connection Verify that the TX and RX cables on the media converter are connected to the RX and TX ports respectively on the other device If the media converter i...

Страница 20: ...urs a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Main Office tel 1 952 941 7600 toll free 1 800 526 9267 fax 952 941 2322 sales transition com techsupport transition com customer...

Страница 21: ...Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilsateur de prende les measures sp cifiques appropri es In accordance with Europe...

Страница 22: ...tura deve essere installata rispettando le norme di sicurezza Elektrisk sikkerhet VIKTIG Dette utstyret skal installeres i samsvar med sikkerhetsregler Seguran a el ctrica IMPORTANTE Este equipamento...

Отзывы: