12
Mx/E-PSW-FX-01
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600
(24 hours)
Technical Specifications
For use with Transition Networks Model Mx/E-PSW-FX-01 converters.
Standards:
IEEE 802.3™, IEEE 802.3af™
Data rate:
10 Mb/s, 100 Mb/s
Dimensions:
1.8"W x 3.35"D x 0.85"H
(45.7 x 85.1 x 21.6 mm)
Weight:
3.2 oz.
(90.7 g)
approximately
Power consumption:
2.6 watts
MTBF*:
49,896 hours
(MIL217F2 V5.0) (MIL-HDBD-217F)
132,736 hours
(Bellcore7 V5.0)
Packet size:
Memory: 9256K bytes
Unicast MAC addresses: 4K
Maximum packet size:
9256K bytes
Power sources:
• Barrel connector - Wall Mount AC adapter
12VDC 400mA
(The external power supply provided
with this product is UL listed by the power supply’s
manufacturer.)
• USB connector: 5VDC
• TP connector IEEE 802.3af™ PSE device: 36 to 57VDC
Environment:
Tmra**:
0°C to 50°C
(32°F to 122°F )
Storage Temp:
-25°C to 65°C
(-13°F to 149°F)
Humidity:
5% to 95%, non-condensing
Altitude:
0 to 10,000 feet
Warranty:
Lifetime
*MTBF is estimated using the predictability method. This method is based on MIL-
217F at 25°C ambient temperature, typical enclosure heat rise of 10°C with nominal
operating conditions and parameters. Installation and configuration specific MTBF
estimates are available upon request. Contact Technical Support.
**Manufacturer’s rated ambient temperature.
WARNING: If the media converter is an IEEE802.3-2005 Powered Device (PD)
capable of receiving power via the Media Dependent Interface (MDI) leads, the power
source, connector, and cable attached to the barrel power connector must meet the
isolation requirement specified in IEEE802.3-2005. Failure to observe this warning
could result in an electrical shock.
CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232,
RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra-
building
(inside plant)
link segments that are not subject to lightening transients or
power faults. Copper-based media ports, e.g., Twisted Pair (TP) Ethernet, USB,
RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter-
building
(outside plant)
link segments that are subject to lightening transients or power
faults. Failure to observe this caution could result in damage to equipment.
[email protected] -- Click the “Transition Now” link for a live Web chat.
13
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the answers
to the following questions and then taking the indicated action:
1.
Is the power LED illuminated and did the TX and FX LEDs turn ON then turn
OFF?
NO
•
Is the device power by an adapter, USB plug, or “Power over Ethernet”?
Is the power adapter the proper type of voltage and cycle frequency for
the AC outlet?
•
Is the power adapter properly installed in the media converter and in the
outlet?
•
Is the USB cable properly installed and its supplied voltage at the proper
level?
(See Technical Spec.)
•
If PoE, is the RJ-45 jack receiving power from the input device?
(See
Technical Spec.)
•
Contact Technical Support: US/Canada: 1-800-260-1312, International:
00-1-952-941-7600.
YES
•
Proceed to step 2.
2.
Note the following:
•
In the link pass-through devices
(MP/E-PSW-FX-01 MU/E-PSW-FX-0)
both copper and fiber cables must be installed before the LEDs will light.
•
The M/E-PSW-FX-01
(no link pass-through option)
, the TX LED will
turn ON when the twisted pair copper cable is installed; the FX LED will
turn ON when the fiber cable is installed.
Technical Specifications -- Continued
Copper-based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422,
RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra-building
(inside plant)
link segments that are not subject to lightening transients or power
faults. Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232,
RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter-
building
(outside plant)
link segments that are subject to lightening transients or power
faults.
The product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
WARNING: Visible and invisible laser radiation when open. Do not stare into the
beam or view directly with optical instruments. Failure to observe this warning could
result in an eye injury or blindness.
WARNING: Use of controls, adjustments, or the performance of procedures other
than those specified herein could result in hazardous radiation exposure.
The information in this user’s guide is subject to change. For the most up-to-date
information, view the user’s guide on-line at: www.transition.com.