Switch Settings and Cable Requirements

Station: Selected when connecting
media converter to terminal device.
Lobe

Selected when connecting

media converter to switch.

1. Is the power LED on the media converter illuminated?

NO

Is the power adapter the proper type of voltage and cycle frequency for AC outlet?  

Is the power adapter properly installed in the media converter and in the outlet?

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 2.

2. Is the Copper SDC Link LED illuminated?

NO

Check UTP cables for proper connection and switch position.  (See above.)

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 3.

3. Is the fiber SDF Link LED illuminated?

NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to RX and TX ports,
respectively, on the other device.

Refer to Tech Tips available at: http://www.transition.com

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

Troubleshooting the Media Converter 

Installation Notes

The physical characteristics of the media cable must meet or exceed IEEE 

802.5t

specifications. 

Token Ring Cable Specifications

Copper Cable Specifications

Category 5 wire or better is required. Either shielded twisted pair (STP) or unshielded
twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.

Category 5:

Gauge

24 to 22 AWG

Attenuation 22 

dB/100’ @ 100 MHz

Differential Characteristic Impedance

100 

±15% 

Maximum Cable Distance:

100 meters (330 feet)

Be certain that the switch is set correctly for site installation. 

Install unit with power supply unit provided.  (Output 9 VDC regulated, 500 mA).

Install no more than two (2) media converters in series.

HSTR-CF-01

Station

Lobe

TR-CF-01

Fiber Cable Specifications

MULTIMODE
Fiber-optic Cable Recommended:

62.5 / 125 µm multimode fiber

*Optional:

100 / 140 µm multimode fiber

85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Fiber-optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Wavelength:

1300nM

Bit error rate:

10-9

Maximum Cable Distance:

2 kilometers

SINGLEMODE
Fiber-optic Cable Recommended:

9 µm singlemode fiber

Wavelength:

1300nM

Bit error rate:

10-9

Fiber-optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.5 dBm

max: -8.0 dBm

Maximum Cable Distance:

20 kilometers

3

4

5

6

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

3

4

5

6

Switch

NOTE: Use small flatblade screwdriver
or similar device to set recessed switch.
Refer to label on top of media converter
for switch settings. 

Twisted pair connection requires two active pairs
configured as straight through. The two active
pairs in a Token Ring network are pins 4 & 5 and
pins 3 & 6. Use only dedicated wire pairs (such
as blue/white & white/blue, orange/white &