100 meters
2 kilometers - multimode
20 kilometers - singlemode
100 meters
100 meters
2 kilometers - multimode
20 kilometers - singlemode
100 meters
Switch Settings and Cable Requirements
Station: Selected when connecting
media converter to terminal device.
Lobe:
Selected when connecting
media converter to switch.
1. Is the power LED on the media converter illuminated?
NO
•
Is the power adapter the proper type of voltage and cycle frequency for AC outlet?
•
Is the power adapter properly installed in the media converter and in the outlet?
•
Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
•
Proceed to step 2.
2. Is the Copper SDC Link LED illuminated?
NO
•
Check UTP cables for proper connection and switch position. (See above.)
•
Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
•
Proceed to step 3.
3. Is the fiber SDF Link LED illuminated?
NO
•
Check fiber cables for proper connection.
•
Verify that TX and RX cables on media converter are connected to RX and TX ports,
respectively, on the other device.
•
Refer to Tech Tips available at: http://www.transition.com
•
Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
•
Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
Troubleshooting the Media Converter
Installation Notes
The physical characteristics of the media cable must meet or exceed IEEE
802.5t
specifications.
Token Ring Cable Specifications
Copper Cable Specifications
Category 5 wire or better is required. Either shielded twisted pair (STP) or unshielded
twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
Category 5:
Gauge
24 to 22 AWG
Attenuation 22
dB/100’ @ 100 MHz
Differential Characteristic Impedance
100
Ω
±15%
Maximum Cable Distance:
100 meters (330 feet)
•
Be certain that the switch is set correctly for site installation.
•
Install unit with power supply unit provided. (Output 9 VDC regulated, 500 mA).
•
Install no more than two (2) media converters in series.
HSTR-CF-01
Station
Lobe
TR-CF-01
Fiber Cable Specifications
MULTIMODE
Fiber-optic Cable Recommended:
62.5 / 125 µm multimode fiber
*Optional:
100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
Fiber-optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.5 dBm
max: -14.0 dBm
Wavelength:
1300nM
Bit error rate:
≤
10-9
Maximum Cable Distance:
2 kilometers
SINGLEMODE
Fiber-optic Cable Recommended:
9 µm singlemode fiber
Wavelength:
1300nM
Bit error rate:
≤
10-9
Fiber-optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.5 dBm
max: -8.0 dBm
Maximum Cable Distance:
20 kilometers
3
4
5
6
Twisted
Pair #1
Twisted
Pair #2
Straight Through Cable
3
4
5
6
Switch
NOTE: Use small flatblade screwdriver
or similar device to set recessed switch.
Refer to label on top of media converter
for switch settings.
Twisted pair connection requires two active pairs
configured as straight through. The two active
pairs in a Token Ring network are pins 4 & 5 and
pins 3 & 6. Use only dedicated wire pairs (such
as blue/white & white/blue, orange/white &