background image

LAN Master™ TX8

12

3

100BASE-TX 8-Port Hub

LAN Master™ TX8 Connectors and Status LEDs

RJ-45 Connectors

Eight (8) 100BASE-TX RJ-45 connectors are located at the front of the
LAN Master™ TX8. The RJ-45  jacks support connection to Category 5
shielded or unshielded 100 ohm twisted pair 100BASE-TX cable. 

Power Connector

An external power connector is located at the back of the LAN
Master™ TX8. 

Status LEDs

Status LEDs are located at the front of the LAN Master™ TX8.

P(

O

)

W

(

E

)

R

Illuminated green:  Hub powered ON.

C

OL

(

LISION

)

Illuminated amber: Collision detected during data
transmission on ANY port.

L

INK

/A

CTIVITY

Illuminated green: Port link established.
Flashing green: Data being received.

P

ARTITION

/J

ABBER

Flashing yellow: Data jabber and error detected
on port.
Illuminated yellow: Port partitioned and isolated.

Warranty Statement

A. Five Year Warranty

Transition Networks, Inc. (TN) warrants, for a period of five years, that TN products (with
the exception of power supplies and fans that TN warrants for two years) will be free from
defects in materials and workmanship, and will be in conformity with TN’s specifications.

TN’s warranty on products manufactured by or assembled for TN in accordance with a
customer’s specifications, is a five-year warranty that the goods conform to such
specifications.

The warranty is invalidated if the goods have been subject to alterations, misuse, accident,
Acts of God (e.g., damage by floods, lightning strikes, Etc.), tampering, improper
maintenance, improper installation, or abuse. If the user is unsure about the proper means
of installing or using the equipment, contact TN’s free Technical Support or Network
Design Services, which can be reached by:

Telephone

1.800.LAN.WANS or 612.941.7600

Fax

612.941.2322

E-mail

[email protected]

Internet

http://www.transition.com

THE ABOVE WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS
ASSEMBLED BY TRANSITION NETWORKS, INC. TO THE EXTENT PERMITTED BY LAW,
TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES, EXCEPT TITLE,
EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF
DESCRIPTION, MERCHANTIBILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-
INFRINGEMENT, AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL
REPRESENTATIONS REGARDING SUCH PRODUCTS MADE BY TN, ITS EMPLOYEES,
AGENTS, OR REPRESENTATIVES.

B. Limitations and Exclusions

If the customer believes any goods sold by TN are defective and within the warranty period,
the following general procedure will be followed:

1. Locate the serial number and delivery date of the item(s).
2. Notify TN within the warranty period.
3. TN will promptly issue a return authorization form for the goods.
4. Upon receiving the form, the customer will promptly return the item(s) at customers

own expense, shipped prepaid, to the distributor from which it was purchased, or
directly to TN.

TN will only accept goods for return if the following conditions have been met:

1. A return form is obtained from TN.
2. The freight charges have been prepaid by the customer.
3. Goods are re-packed in their original packaging.

If under warranty TN shall, at its option, (1) repair the goods free of charge (2) replace the
goods free of charge, or (3) accept the return of the item(s) and credit the current price to
the reseller (within 90 days of purchase), or (4) if the goods are not under warranty, will
repair the item(s) at a minimum charge of USD $200 (two hundred U.S. dollars) per item.

THIS IS THE EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY. IN NO EVENT
SHALL TRANSITION NETWORKS BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY KIND, WHETHER FOR BREACH OF ANY
CONDITION OF SALE, FOR NEGLIGENCE, ON THE BASIS OF STRICT LIABILITY,
CONTRACT, OR OTHERWISE AND IRRESPECTIVE OF WHETHER TN IS INFORMED BY
CUSTOMER OF THE POSSIBILITY OF SUCH DAMAGES IN ADVANCE OF THIS SALE.

Содержание HB-E-TX-8

Страница 1: ...aintaining the TRANSITION Networks LAN Master TX8 100BASE TX 8 Port Hub contact TRANSITION Networks Technical Support at 800 260 1312 or contact your local distributor 33013 C LAN Master TX8 HB E TX 8 100BASE TX 8 Port Hub LAN Master TX8 17 ...

Страница 2: ... A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Copyright Restrictions 1996 1997 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Trademark Notice All re...

Страница 3: ... better is required Either shielded twisted pair STP or unshielded twisted pair UTP can be used DO NOT USE FLAT OR SILVER SATIN WIRE Category 5 Gauge 24 to 22 AWG Attenuation 20 dB 1000 10 MHz Impedance 100 Ω 10 10 MHz Maximum Cable Distance 100 meters 330 feet 100BASE TX CONNECTOR CHARACTERISTICS The 100BASE TX connectors are standard RJ 45 connectors with standard pinning The two active pairs in...

Страница 4: ...CIFICATIONS Due to the limited collision domain in 100BASE X use the shortest cables possible to make a connection between any two devices Where collisions are not a consideration full duplex longer cable may be possible Effective cable distances are determined by ambient RF noise and by signal loss in the cable Since fiber has low signal loss meter and invulnerability to RF noise fiber is the pre...

Страница 5: ...n Procedure The customer must follow this procedure for the return of defective items 1 Locate the serial number s of the item s to be returned 2 Determine the date the item s was received 3 Contact Transition Networks Technical Support to determine if the problem can be corrected on site If not and the product is covered by warranty then Call the distributor directly or contact TN Request a Retur...

Страница 6: ...ion com THE ABOVE WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TRANSITION NETWORKS INC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL R...

Страница 7: ... open and attempt to repair the LAN Master TX8 100BASE TX 8 Port Hub Failure to observe this warning could result in personal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation If two network devices fail to communicate through the LAN Master TX8 consider the following Are the LEDs described in the previous section fun...

Страница 8: ...ould include the following Item Part Number LAN Master TX8 HB E TX 8 Power Cord 3344 3347 3348 3349 or 3523 depending upon power configuration in country where installed User s Guide 33012 4 OPERATION The LAN Master TX8 normally requires no intervention beyond occasionally monitoring the Power and Port Status LEDs Status LEDs Status LEDs are located at the front of the LAN Master TX8 P O W E R Ill...

Страница 9: ...er TX8 to be installed 2 Carefully align the LAN Master TX8 between the 19 inch rack mounting rails at the installation position 3 Install two screws through right front bracket and two screws through left front bracket using clip nuts if necessary Connecting Power to LAN Master TX8 To power ON the LAN Master TX8 1 Locate the power receptacle on the back of the LAN Master TX8 2 Connect the LAN Mas...

Страница 10: ...to Port 8 connector marked MDI X 3 Connect male RJ 45 plug connector at other end of 100BASE TX cable to Port 8 connector marked MDI Up to 5 meters Connecting 100BASE TX Cable To connect 100BASE TX Cable to LAN Master TX8 RJ 45 connectors 1 Locate or build 100BASE TX cables with the following characteristics 803 2 compliant See page 15 cable length less than 100 meters male RJ 45 plug connectors i...

Отзывы: