CABLE SPECIFICATIONS

The physical characteristics of the media cable must meet or exceed IEEE 802.3
specifications. 

Copper Cable and Connector 

Category 3 or better twisted-pair copper wire is required. Either shielded twisted-pair (STP) or
unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.

CATEGORY 3:

Gauge

24 to 22 AWG

Attenuation 

11.5 dB/100m @ 5-10 MHz

Maximum Number of Nodes

2 nodes

Maximum Cable Distance

100 meters

RJ-45 Pin-outs

Pin 1=TD+, Pin 2=TD-,
Pin 3=RTD+, Pin 6=RD-

Twisted pair connection requires two active pairs configured as straight through. The two
active pairs in an Ethernet™ network are pins 1 & 2 and pins 3 & 6. Use only dedicated wire
pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pairs. 

NOTE: Crossover cable used for transceiver-to-transceiver or transceiver-to-DTE; Straight-
through cable used for transceiver-to-hub, switch, or any hub crossed over,.

AUI (DB-15) Interface 

INSTALLATION 

Set Switches

NOTE: UP enables the indicated function
on the 4-position switch located to the right
of the 10BASE-T connector and DOWN
disables the indicated function.

1

SQE Test: Controls SQE test
function. Disable this function when connecting to IEEE 802.3
compliant repeaters. Enable this function when connecting to other
devices. Default is enabled (UP).

2

LinkALERT: Enables the LinkALERT function. With the switch down,
the transceiver implements the standard Link Integrity Test. Default
is enabled (UP).

3

Polarity Correction: Corrects for a receive pair with reversed
polarity.  In both switch positions reversed polarity is indicated by 5
Status LED blinks. Default is enabled (UP).

4

Extended Distance: Increases receiver sensitivity to allow operation
with high loss cables or data grade cables longer than 100 meters.
NOTE: Do not use this feature unless necessary; Extended Distance
makes the transceiver more susceptible to plant noise and crosstalk.
Default is disabled (DOWN).

Install Cable

NOTE: See page 6 for cable specifications and configurations. 

NOTE: KEEP TWISTED PAIR RUNS AS SHORT AS POSSIBLE. 

1.

Locate or build 10BASE-T compliant cables with male RJ-45 plug
connectors at both ends.

2.

Connect male RJ-45 plug connector at one end of cable to
transceiver RJ-45 jack connector.

3.

Connect male RJ-45 plug connector at other end of cable to
10BASE-T device RJ-45 jack connector.

Connect to Power

The E-TBT-MC03 is powered through the AUI connection.

Twisted
Pair  #1

Twisted
Pair  #2

Crossover Cable

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

Parameter

Minimum

Typical

Maximum

Transmit
Transmit threshold voltage level:

-140mV

-170mV

-190mV

Transmit turn on delay:

100ns

Transmit steady propagation delay:

15ns

50ns

Transmit loop back start up delay:

500ns

Transmit turn off to data idle:

400ns

2100ns

SQE test delay:

0.6 µ sec

1.6 µ sec

SQE test duration:

0.5 µ sec

1.0 µ sec

1.5 µ sec

Receive
Receive turn on delay:

350ns

Receive steady propagation delay:

15ns

50ns

Differential output voltage (RX(-/+)):

(+/-)550mV

(+/-)1200

Differential output voltage (col(-/+)):

(+/-)550mV

(+-)1200

Differential output rise time (RX(-/+), col(-/+)): 4ns
Differential output fall time (RX(-/+), col(-/+)): 4ns
Collision
Time for SQE to deact. after collision:

450ns

700ns

Collision frequency:

8.5MHz

11.5MHz

Collision pulse duty cycle:

40%

50%

60%

SQE test delay:

0.6 µ sec

1.6 µ sec

Jabber activation delay:

20ms

70ms

150ms