![Transition Networks E-TBT-FRL-05(L) Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/transition-networks/e-tbt-frl-05-l/e-tbt-frl-05-l_user-manual_1151836004.webp)
6
24-hour Technical Support:
1-800-260-1312
International:
00-1-952-941-7600
E-TBT-FRL-05
Technical Specifications
S
tandards
IEEE 802.3™
Data Rate
10 Mb/s
Case Dimensions
3.9" x 3.0" x 1.0"
(99mm x 76mm x 25mm)
Shipping Weight
6 oz. (181 g)
Power Supply
E-TBT-FRL-05, E-TBT-FRL-05(SC), E-TBT-FRL-05(SM),
DC Output
E-TBT-FRL-05(L), E-TBT-FRL-05(MT), E-TBT-FRL-05(LH),
E-TBT-FRL-05(XC), E-TBT-FRL-05(LW): 12VDC, 0.5 A
(minimum)
E-TBT-FRL-05(HT), E-TBT-FRL-05(SCHT),
E-TBT-FRL-05(SMHT), E-TBT-FRL-05(XCHT),
E-TBT-FRL-05(XLHT): 9VDC, 1.0 A
(minimum)
minimum output regulation: 5%
Connector: 2.1mm barrel, center pin positive
MTBF
54,337 hours
(MIL217F2 V5.0) (MIL-HDBK-217F)
131,255 hours
(Bellcore7 V5.0)
Tmra*
E-TBT-FRL-05, E-TBT-FRL-05(SC), E-TBT-FRL-05(SM),
E-TBT-FRL-05(L), E-TBT-FRL-05(MT), E-TBT-FRL-05(LH),
E-TBT-FRL-05(XC) E-TBT-FRL-05(LW): 0°C to 50°C
(32°F to 122°F)
E-TBT-FRL-05(HT), E-TBT-FRL-05(SCHT),
E-TBT-FRL-05(SMHT), E-TBT-FRL-05(XCHT),
E-TBT-FRL-05(XLHT): -25°C to 70°C
(-13°F to 158°F)
Environment
Storage Temperature: -20°C to 85°C
(-4°F to 185°F)
Humidity:
5 to 95%, non condensing
Altitude:
0 to 10,000 feet
Warranty
Lifetime
*Manufacturer’s rated ambient temperature.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
WARNING: Visible and invisible laser radiation when open. Do not stare into the beam or
view the beam directly with optical instruments. Failure to observe this warning could result
in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures other than those
specified herein may result in hazardous radiation exposure.
IMPORTANT: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232,
RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra-building
(inside plant)
link segments that are not subject to lightening transients or power faults.
Copper-based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485,
DS1, DS3, Video Coax, etc., are NOT to be connected to inter-building (
outside plant)
link
segments that are subject to lightening transients or power faults.
The fiber optic transmitters on this device meet Class I Laser safety requirements
-- Click the
“Transition Now”
link for a live Web chat.
7
Crossover Cable
1
2
3
6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1
2
3
6
1
2
3
6
1
2
3
6
Cable Specifications
Copper Cable
Category 3:
(minimum requirement)
Gauge
24 to 22 AWG
Attenuation
11.5 dB/100m @ 5-10 MHz
Maximum Cable Distance
100 meters
• Straight-through or crossover cable may be used.
• Do not use flat or silver satin wire.
• Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)