CABLE SPECIFICATIONS

The physical characteristics of the media cable must meet or exceed IEEE 802.3
specifications. 

Fiber Cable 

850NM MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

Minimum:

-15 dBm

Fiber Optic Receiver Sensitivity:

Minimum :

-33 dBm

Bit error rate:

10

-10

Maximum Cable Distance:

2 kilometers (6,600 feet

1300NM MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

Minimum:

-17 dBm

Fiber Optic Receiver Sensitivity:

Minimum:

-35 dBm

Bit

error rate:

10-9

Maximum Cable Distance:

5 kilometers (16,500 feet)

1300NM SINGLEMODE (ST)

Fiber Optic Cable Recommended:

9/125 micron single mode fiber

Fiber Optic Transmitter Power:

Minimum:

-27 dBm

Fiber Optic Receiver Sensitivity:

Minimum:

-36 dBm

Bit error rate:

10

-10

Maximum Cable Distance:

20 kilometers (66,000 feet)

1300NM SINGLEMODE (SC)

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

Minimum:

-15.5 dBm

Fiber Optic Receiver Sensitivity:

Minimum :

-36.9 dBm

Bit error rate:

10

-10

Maximum Cable Distance:

20 kilometers (66,000 feet)

Copper Cable and Connector 

Category 3 or better twisted-pair copper wire is required. Either shielded twisted-pair (STP) or
unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.

CATEGORY 3:

Gauge

24 to 22 AWG

Attenuation 

£

11.5 dB/100m @ 5-10 MHz

Maximum Number of Nodes

2 nodes

Maximum Cable Distance

100 meters (200 meters with better cable

RJ-45 Pin-outs

Pin 1=TD+, Pin 2=TD-,
Pin 3=RTD+, Pin 4=RD-

Twisted pair connection requires two active
pairs configured as straight through. The two
active pairs in an Ethernet™ network are pins
1 & 2 and pins 3 & 6. Use only dedicated wire
pairs (such as blue/white & white/blue,
orange/white & white/orange) for the active
pairs.

INSTALLATION 

Set MDI/MDI-X Switch

NOTE: Straight-through/crossover 10BASE-T
requirements are satisfied using the MDI/MDI-X
switch with straight-through cable. See page 6 for
cable configurations. 

Using small flatblade screwdriver or similar tool
and referring to label at front of media converter,
set MDI/MDI-X switch position for site installation.

10BASE-T cable connections between a hub and
the media converter require the MDI/MDI-X switch to be set to MDI.
10BASE-T cable connections between the media converter and a terminal,
transceiver or NIC require the switch to be set to MDI-X

Install Cable

NOTE: See page 6 for cable specifications. 

COPPER

NOTE: KEEP TWISTED PAIR RUNS AS SHORT AS POSSIBLE. 

Locate or build 10BASE-T-compliant cables with straight-through
or crossover configuration and with male RJ-45 plug connectors
at both ends.

Connect male RJ-45 plug connector at one end of cable to media
converter RJ-45 jack connector.

Connect male RJ-45 plug connector at other end of cable to
10BASE-T terminal device RJ-45 jack connector (using straight-
through cable configuration) or to 10BASE-T hub RJ-45 jack
connector (using crossover cable configuration).

FIBER

Locate or build 10BASE-FL-compliant fiber cable with male two-
stranded TX to RX connectors at both ends.

Connect male TX and RX cable connectors at one end of cable to
TX and RX female connectors, respectively, on media converter.

Connect male TX and RX cable connectors at other end of cable
to RX and TX connectors of 802.3 compliant fiber device.

Connect to Power

Install power adapter cord at back of media converter.

Connect power adapter plug to AC power.

Verify that media converter is powered by observing illuminated
LED(s).

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

MDI

position

MDI-X

position