CABLE SPECIFICATIONS
The physical characteristics of the media cable must meet or exceed IEEE 802.3
specifications.
Fiber Cable
MULTIMODE
Fiber Optic Cable Recommended:
62.5 / 125 µm multimode fiber
Optional:
100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -32.5 dBm
max: -14.0 dBm
Wavelength :
850nM
Bit error rate:
≤
10-9
Maximum Cable Distance:
2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended:
9 µm singlemode fiber
Wavelength:
1300nM
Bit error rate:
≤
10-9
Fiber-optic Transmitter Power:
min: -15.0 dBm
max: -8.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.5 dBm
max: -8.0 dBm
Maximum Cable Distance:
20 kilometers
Copper Cable
Category 5 twisted-pair copper wire is required. Either shielded twisted-
pair (STP) or unshielded twisted-pair (UTP) can be used. DO NOT USE
FLAT OR SILVER SATIN WIRE.
CATEGORY 5:
Gauge
24 to 22 AWG
Attenuation 20
dB/1000’ @ 10 MHz
Differential Characteristic Impedance
100
Ω
±10% @ 10 MHz
Maximum Cable Distance:
100 meters
INSTALLATION
Set Switches
NOTE: Switch labels are located AT TOP of E-R-TX-FX-01 media converter.
Use small flatblade screwdriver or
similar device to set recessed
switches according to site
installation.
•
Set EACH MDI/MDI-X
switch to MDI for cable
connection between
switch and media
converter OR to MDI-X
for cable connection
between media converter and terminal,
transceiver or network interface card (NIC).
•
Referring to drawing, set four-position
switch according to network
configuration.
NOTE: If connecting two (2) media converters in series, set the PST (#4)
switch on one media converter to the UP position AND set the PST (#4)
switch on the other media converter to the DOWN position.
Install Cable
COPPER
NOTE: KEEP TWISTED PAIR RUNS AS SHORT AS POSSIBLE.
•
Locate or build 802.3 compliant cables with straight through
configuration and male RJ-45 plug connectors.
•
Connect male RJ-45 plug connector at one end of cable to media
converter RJ-45 jack connector.
•
Connect male RJ-45 plug connector at other end of cable to DTE
terminal RJ-45 jack connector (with MDI switch set to MDI-X) or to
switch RJ-45 jack connector (with MDI switch set to MDI).
FIBER
•
Locate or build 802.3 compliant fiber cable with male two-stranded TX
to RX connectors appropriate to the media converter installed at both
ends.
•
Connect male TX and RX cable connectors at one end of cable to TX
and RX female connectors, respectively, on media converter.
•
Connect male TX and RX cable connectors at other end of cable to RX
and TX connectors of 802.3 compliant fiber device.
Connect to Power
•
Install Power Adapter cord at back of media converter.
•
Connect Power Adapter 3-prong plug to AC power.
•
Verify that media converter is powered by observing illuminated LED(s).
The two active pairs in a 100BASE-TX
network are pins 1 & 2 and pins 3 & 6. Use
only dedicated wire pairs (such as
blue/white & white/blue, orange/white &
white/orange) for the active pins.
1
2
3
6
Twisted
Pair #1
Twisted
Pair #2
Straight Through Cable
1
2
3
6
MDI-X
position
MDI
position
Auto-negotiation UP=ON
(not used)
Full/Half-duplex
UP=FULL
PST
UP=11 sec
DOWN=5 sec
1 2 3 4