background image

Minneapolis, MN  55344  USA

100BASE-FX

Fast Ethernet

Unmanaged Fiber Hub with TX or FX Uplink

E-FX-HB-1600, E-FX-HB-0800

USER’S GUIDE

The stackable, rack-mountable E-FX-HB-1600 and E-FX-HB-0800 series
unmanaged Fast Ethernet

fiber hubs allow the network administrator to

set up and to modify workgroups connected over fiber and to install an
optional copper or fiber backbone uplink connection to the workgroups
and/or optional connections for stacking up to five hubs.
E-FX-HB-1600, E-FX-HB-1600(SC)

The E-FX-HB-1600 hub provides sixteen (16) Fast Ethernet

ST OR SC

fiber connections to terminal devices plus space for an optional copper or
fiber backbone uplink and space for an optional stacking adapter. 

E-FX-HB-0800, E-FX-HB-0800(SC)

The E-FX-HB-0800 hub provides eight (8) Fast Ethernet

ST OR SC fiber

connections to terminal devices plus space for an optional copper or fiber
backbone uplink and space for an optional stacking adapter. 

BACKBONE UPLINK ADAPTERS Optional devices ordered separately that, when
installed, provide one of the following Fast Ethernet

backbone uplink connections:

MA-FST

ST connector to multimode fiber

MA-FSC

SC connector to multimode fiber 

MA-FSM

• 

SC connector to singlemode fiber 

MA-TX

RJ-45 connector to twisted-pair copper, AutoCross

feature 

STACKING ADAPTERS  Optional
devices ordered separately that, when
installed, allow stacking between E-FX-
HB-xx00 hubs.

ACC-0200

Stacking adapter

ACC-0201

Stacking cable 

E-FX-HB-xx00 in the Network  . . . . .2
Installation  . . . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . . .11
Fault Isolation and Correction  . . . .12
Cable Specifications  . . . . . . . . . . . .14
Technical Specifications  . . . . . . . . .15
Compliance Information . . . . . . . . .16

STAT

PWR

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

4

5

7

6

8

9

11

10

12

13

15

14

16

STAT

PWR

COL

100BASE-FX

1

2

3

4

5

6

7

8

ACT

GFT

BB

1

3

2

4

5

7

6

8

COMPLIANCE INFORMATION

UL Listed 
C-UL Listed (Canada)
CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to part 15 of the FCC rules.  These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.  This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.  Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on
the radio interference regulations of the Canadian Department of Communications.

Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables

aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.

European Regulations

Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen
werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques
appropriées

VCCI Class 1 Compliance

This equipment is in the 1st Class category (information equipment to be used in commercial and/or
industrial areas) and conforms to the standards set by the Voluntary Control Council For Interference by
Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in
commercial and/or industrial areas.  When used in a residential area or in an adjacent area thereto,
interference may be caused to radio and TV receivers, etc.  Read the instructions for correct handling.

Trademark Notice

All registered trademarks and trademarks are the property of their respective owners.

Copyright Restrictions

© 1999 TRANSITION Networks.
All rights reserved.  No part of this work may be reproduced or used in any form or by any means –
graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A.

33122.A

CAUTION:  RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.

Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität. 

Содержание E-FX-HB-0800

Страница 1: ... harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassan...

Страница 2: ...HB 1600 or E FX HB 0800 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class A EN 55022 1988 Class A EN 50082 1 1992 EN 60950 A4 1997 IEC 801 2 IEC 801 3 and IEC 801 4 IEC 950 I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s _November 10 1999_____ Stephen Anderson Vice President of...

Страница 3: ...times To calculate a collision domain round trip delay in bit times find the longest path between any two terminal devices in the collision domain Calculate the round trip delay by multiplying the length of the cable in meters by the delay per meter in bit times BT then take the sum of all cable delays plus station DTE repeater and multi port media converter port delays If the result is less than ...

Страница 4: ...n adapter securely against internal mating E FX HB xx00 component until expansion adapter faceplate is flat against E FX HB xx00 chassis 5 Secure expansion adapter by installing retained screws through expansion adapter into E FX HB xx00 chassis YES Continue at step 7 7 Is one or more of the 100BASE FX STAT us LEDs illuminated continuously YES Continue at step 10 NO Continue at step 8 8 Does one o...

Страница 5: ... to restart the initialization process Contact Technical Support 800 260 1312 Optionally Install Backbone Uplink Adapter WARNING Remove AC line cord from power source before installing backbone uplink adaptor in E FX HB xx00 Failure to observe this warning could result in personal injury or death CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing backbo...

Страница 6: ...rubber foot Position and secure each rubber foot as shown 3 Return E FX HB xx00 to upright position OPERATION Use the status LEDs to monitor E FX HB xx00 operation in the network HUB INDICATORS P o W e R Steady LED indicates E FX HB xx00 is connected to external AC power COL lision Flashing LED indicates network collisions G lobal F ault S tatus Steady LED indicates the presence of a partitioned o...

Страница 7: ... one end of adapter cable to UPPER connector on expansion adapter on lowest hub in stack 3 Install one end of adapter cable to LOWER connector on expansion adapter on next hub in stack 4 Continue steps 2 3 until installation is complete AT FRONT To cascade hubs by installing fiber cables between hubs 1 Locate or build 100BASE FX compliant two stranded fiber cable with appropriate TX to RX connecto...

Страница 8: ...cate 100BASE FX uplink adapter installed at E FX HB xx00 back See page 5 2 Locate or build 100BASE FX compliant fiber cable with male two stranded TX to RX connectors at both ends See page 14 3 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on E FX HB xx00 100BASE FX uplink adapter 4 Connect male TX and RX cable connectors at other end of ca...

Отзывы: