Transition Networks E-CX-TBT-04 Скачать руководство пользователя страница 4

4

3

50 ohm terminator

50 ohm terminator

GND

C

oax Config Switch

Set to 0

straight-through

crossover

OR

TX

TX

TX

RX

OR

OR

C

oax Config Switch

Set to 50

50 ohm terminator

C

oax Config Switch

Set to 0

50 ohm terminator

GND

50 ohm terminator

GND

MEDIA CONVERTERS in the NETWORK

E-CX-FRL-04

Setting the Coax Configuration Switch:

Set switch position to 50 ohms when connecting the end
of a thin coax segment DIRECTLY to the media converter's
BNC port. (NOTE: The minimum coax cable length must
be 0.5 meters.)

Set switch position to 0 ohms when connecting to the
middle or in line of a thin coax segment. (NOTE: For this
position a BNC "T" must be connected to the media
converter's BNC port).  

TRANSITION Networks media converters provide media
connections to and from 10BASE-T, 10BASE-2, and 10BASE-FL. 

E-CX-TBT and E-CX-FRL both require the coax configuration switch to be set and the coax segment to be grounded.

E-CX-TBT-04

Configuring 10BASE-T Straight Through/Crossover
Cable Assembly

The two active pairs  in a 10BASE-T network are pins 1 & 2
and pins 3 & 6. Use only dedicated wire pairs (such as
blue/white & white/blue,
orange/white & white/orange) for
the active pins. 

Cable connections between a
hub and the media converter
must be configured as straight
through
. Cable connections
between the media converter and
a terminal, transceiver or NIC

E-CX-TBT requires straight through/crossover 10BASE-T cable configuration.

Twisted
Pair  #1

Twisted
Pair  #2

Crossover Cable

Connectors for like devices

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

Connectors for unlike devices