The 6-position switch
•
The 6-position switch is
located on the side of the
media converter.
•
Use a small flat blade
screwdriver or a similar
device to set the recessed
switches.
•
Refer to the drawing to the
right for definitions of the
individual switch positions.
1.
TP Auto-Negotiation
up
Enables
down
Disables
2.
TP Duplex
(Only valid if SW1 is Down)
up
Full
down Half
TP Auto-Negotiate
(Up=Enabled, Down Disabled)
TP Duplex
(Up=Full, Down=Half)
TP Speed
(Up=100Mbs, Down=10Mbs)
Fiber Duplex
(Up=Full, Down=Half)
TLPT
(Up=Enabled, Down=Disabled)
Center/Terminal
(Up=C, Down=T)
1
2
3
4
5
6
UP
Down
Typical system configuration
Remote Terminal Converter
SW6 set to ‘Terminal’
Chassis Center Converter
SW6 set to ‘Center’
Fiber Cable
Chassis
Network
Network
Note:
The Loopback test occurs over the fiber connection.
[email protected] -- Click the “Transition Now” link for a live Web chat.
3
Hardware/software mode jumper
The jumpers are located on the media converter circuit board. Use small needle-
nosed pliers or a similar converter to set the jumper.
The Hardware/Software jumper is labeled “H” for hardware and “S” for software.
Hardware The media converter mode is determined
by the settings on the 6-position switch.
Software
The media converter mode is determined
by the most recently saved, on-board
microprocessor settings.
Note:
Software Mode only when the SW6 of the chassis converter is in the UP
position
(center)
.
J6
Hardware/Software
1
2
3
H
Pins
S
H
S
Installation -- Continued
The 6-position switch--continued
3.
TP Speed
(Only valid if SW1 is Down)
up
100Mbps
down
10Mbps
4.
Fiber Duplex
up
Forces full duplex operation on the fiber port.
down
Forces half duplex operation on the fiber port.
5.
Transparent Link Pass Through (TLPT)
up
Enabled
down Disabled
6.
Center/Terminal Mode
(see note)
up
Center mode
(center converter only)
down Terminal
mode
(terminal converter only)
Note:
To use the TS1000 compliant Center/Terminal mode function, set SW6 on
the center converter in the chassis to Center Mode, the (UP) position; on the
terminal converter at the remote location, set SW6 to Terminal Mode, the
(DOWN) position. This allows you to view parameters of the terminal
converter from the center converter for monitoring purposes only .