![Transition Networks CSETF1011 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/transition-networks/csetf1011/csetf1011_user-manual_1151766003.webp)
CABLE SPECIFICATIONS
The physical characteristics of the media cable must meet or exceed IEEE 802.3
specifications.
Fiber Cable
MULTIMODE
Fiber Optic Cable Recommended:
62.5 / 125 µm multimode fiber
Optional:
100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
Wavelength :
850 nM
Attenuation:
≤
3.75 dB/ 1 kilometer @ 850 nM
Fiber-optic Transmitter Power:
min: -16.0 dBm
max: -10.0 dBm
Fiber-optic Receiver Sensitivity:
min: -29.50 dBm
max: -7.2 dBm
Link Budget
13.5 dB
Typical Maximum Cable Distance:*
Full-duplex
300 meters @ 100 Mb/s
2 kilometers @ 10 Mb/s
Half Duplex: See page 4
*Actual distance dependent upon physical characteristics of network installation.
Copper Cable
Category 5 twisted-pair copper wire is required. Either shielded twisted-pair
(STP) or unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR
SILVER SATIN WIRE.
CATEGORY 5:
Gauge
24 to 22 AWG
Attenuation
22.0 dB /100m @ 100 MHz
Maximum Cable Distance:
100 meters
The two active pairs in an Ethernet™ network are pins 1 & 2 and pins 3 & 6. Use
only dedicated wire pairs (such as blue/white & white/blue, orange/white &
white/orange) for the active pins.
Twisted pair connection requires two active pairs configured as straight through or
crossover, as shown:
RJ-45 Pin-out:
Pin 1=TD+, Pin 2=TD-, Pin 3=RD+, Pin 6=RD-
Use the the CSETF10xx media converter to connect a 10BASE-T or
100BASE-TX terminal device and a 10BASE-FL or 100BASE-SX (half-duplex
only) hub, switch, or router:
Or use the the CSETF10xx media converter to connect a 10BASE-T or
100BASE-TX hub, switch, or router and a 10BASE-FL or 100BASE-SX terminal
device:
Crossover
1
2
3
6
Straight Through
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1
2
3
6
1
2
3
6
1
2
3
6
10BASE-T
INPOR
T
MCCM10
MGMT MASTER
RX
TX
LNK
PWR
OUTPOR
T
RESET
DB-9
12C
12C-1
TERM
INIT
CETTF100
CFETF110
LKF
PWR
RXF
RXC
LKC
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
10/100TX
RX
TX
10/100SX
CFETF100
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
100BASE-FX
10BASE-T
10BASE-FL
Media
Conversion
Center
Power
In Use
1
Power
In Use
2
PWR
LKC
SPD
FRX
CRX
10/100TX
RX
TX
10/100SX
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
100BASE-FX
10BASE-T
INPOR
T
MCCM10
MGMT MASTER
RX
TX
LNK
PWR
OUTPOR
T
RESET
DB-9
12C
12C-1
TERM
INIT
CETTF100
CFETF110
LKF
PWR
RXF
RXC
LKC
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
10/100TX
RX
TX
10/100SX
CFETF100
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
100BASE-FX
10BASE-T
10BASE-FL
Media
Conversion
Center
Power
In Use
1
Power
In Use
2
PWR
LKC
SPD
FRX
CRX
10/100TX
RX
TX
10/100SX
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
100BASE-FX