Installation 

CAUTION: Wear a grounding device and observe electrostatic discharge precautions
when setting the jumper, the 6-position switch, and installing the CGETF10xx-10x
media converter into the 

PointSystem™

chassis. Failure to observe this caution could

result in damage to the media converter.

Set the 2-position jumper 

The jumper is located on the media converter circuit board, connector J5.

Use a small needle-nosed pliers or similar device to set the jumper. 

Refer to the illustration on the right for hardware/software jumper positioning. 

Hardware

The media converter’s mode of operation is

determined by the 6-position switch
settings. Default is the Hardware position.

Software

The media converter’s mode of operation is

determined by the most recently saved on-
board microprocessor settings.

Set the 6-position switch

The 6-position switch is located on the side of the media converter. 

Use a small flat-blade screwdriver to set the DIP switches. 

All switches are shown in the
default position, UP. 

Note:

Switch positions S2 and S3
function together to configure
the media converter for Pause
conditions. 

S1 Remote-Fault Detection

up

Disabled

down

Enable 

S2 & S3 work in combination 

Pause
10 sw position 2 up and 3 down: 

Symmetric

01 sw position 2 down and 3 up: 

Asymmetric

11 sw positions 2 and 3 up:  Pause is OFF 

(default position)

00 sw positions 2 and 3 down: 

Symmetric and Asymmetric

S4 Transparent Link Pass-Through

up

Enable Link Pass-Through

down

Disable Link Pass-Through

H

S

o

ft

wa

r

e Mo

d

e

S

H

Ha

rd

wa

r

e Mo

d

e

S

2. Pause 

(symmetric) 

3. Pause 

(asymmetric) 

4. Transparent Link Pass-Through

5. Auto-Negotiation

1. Remote Fiber Fault Detect 

6. Loop Back

[email protected] -- Click the “Transition Now” link for a live Web chat.

5

Installation 

-- Continued

Set the 6-position switch -- continued

S5 Fiber Auto-Negotiation

up

Disable Auto-Negotiation for the fiber link (

default setting)

down

Enable Auto-Negotiation for the fiber link

S6 Loop Back

up

Disable RX/TX signal loop back 

(default setting)

down

Enable RX/TX signal loop back 

Install Mode
During installation, set DIP switch 4  DOWN; leave all other switches in the UP
position 

(default)

. This disables Transparent Link Pass-Through and Auto-

Negotiation, allowing individual copper and fiber links to be established 

(both

copper port LEDs will turn ON with each device-to-device connection) 

independent

of having a complete end-to-end connection.  
Operation Mode
After installation is complete 

(all copper and fiber ports connected and linked),

set

all switches to the UP position 

(default)

.

Remote Fiber Fault Detect
Remote fiber fault detect (RFD) monitors the status of the fiber link. Enable RFD in
the remote converter only. 
CAUTION: If RFD is enabled in the device at each end of the link, a link pass-
through event will put the converters into an unrecoverable state 

(unable to

establish a link)

.

Fiber Auto-Negotiation
Fiber Auto-Negotiation allows the fiber interface to detect and then advertise the
supported features of the remote device—active only when a fiber cable is
connected to a device with a negotiating port. The process is as follows: 
1.

The fiber interface detects the supported features of the remote partner.

2.

These abilities are passed to the twisted-pair interface and advertised.

3.

Once the twisted-pair interface has a link at the highest common capability, it
passes the result to the fiber interface.

4.

The fiber interfaces then start advertising these capabilities. At this point, the
link between the fiber and the negotiating port is complete.

If the CGETF10xx-1xx is connected via fiber to another CGETF10xx-1xx, both
media converters must have the Fiber Auto-Negotiation setting disabled 

(switch 5

UP)

.

Note:

Transparent Link Pass-Through 

(switch position 4 enabled)

cannot be

turned OFF (

disabled) 

when Fiber Auto-Negotiation is ON 

(enabled). 

Содержание CGETF1013-110

Страница 1: ...1000Base SX 850 nm multimode 220 m 721 ft 62 5 125 m cable 550 m 1 804 ft 50 125 m cable CGETF1014 110 RJ 45 1000Base T 100 m 328 ft SC 1000Base LX 1310 nm single mode 10 km 6 2 miles CGETF1015 110 RJ...

Страница 2: ...endent upon the physical characteristics of the network Note Third party Multi Source Agreement MSA compliant Small Form Factor Pluggables SFPs can also be used in the CGETF1040 11x Sold separately th...

Страница 3: ...t the 6 position switch continued S5 Fiber Auto Negotiation up Disable Auto Negotiation for the fiber link default setting down Enable Auto Negotiation for the fiber link S6 Loop Back up Disable RX TX...

Страница 4: ...port 3 Connect the fiber cables to the other device another media converter hub etc as described Connect the male TX cable connector to the female RX port Connect the male RX cable connector to the fe...

Страница 5: ...on the copper link media converter B disables the copper link media converter A disables the fiber TX link 3 2 media converter B loses the fiber RX link techsupport transition com Click the Transitio...

Страница 6: ...available on all devices techsupport transition com Click the Transition Now link for a live Web chat 11 Cable Specifications The physical characteristics must meet or exceed IEEE 802 3 specification...

Страница 7: ...000 hours Bellcore7 V5 0 Operating Temp Tmar 0 C to 50 C 32 F to 122 F Storage Temp 15 C to 65 C 5 F to 149 F Humidity 10 to 90 non condensing Altitude 0 to 10 000 feet Warranty Lifetime MTBF is esti...

Страница 8: ...itialization process Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 YES Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 techsupport transition com Click the Transition Now lin...

Страница 9: ...s aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European regulations Warning This is a Class...

Отзывы: