Transition Networks CFETF1029-205 Скачать руководство пользователя страница 6

CFETF1029-2xx

10

24-hour Technical Support: 1-800-260-1312   International: 00-1-952-941-7600 

Troubleshooting

If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:

1.

Is the PWR LED on the media converter illuminated?
NO

Is the media converter slide-in-module installed properly in the
chassis?

Is the power cord properly installed in the chassis and at the external
power source?

Does the external power source provide power?

Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

YES

Proceed to step 2.

2.

Is the LKC LED on the media converter illuminated?
NO

Check the twisted-pair cables for proper connection.

Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

YES

Proceed to step 3.

3.

Is the LKF LED on the media converter illuminated?
NO

Check the fiber cables for proper connection.

Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

YES

Proceed to step 4.

4.

Is the RXC LED on the media converter flashing?
NO

If there is no activity on the 100Base-TX port, proceed to step 5.

If there is activity on the 100Base-TX port, disconnect and reconnect
the 100Base-TX cable to restart the initialization process.

Restart the workstation to restart the initialization process.

Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

YES

Proceed to step 5.

5.

Is the RXF LED on the media converter flashing?
NO

If there is no activity on the 100Base-FX port, continue below

If there is activity on the 100Base-FX port, disconnect and reconnect
the 100Base-FX cable to restart the initialization process.

Restart the workstation to restart the initialization process.

Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

YES

Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

[email protected] -- Click the “Transition Now” link for a live Web chat.

11

Contact Us

Technical support

Technical support is available 24 hours a day.
US and Canada:

1-800-260-1312

International:

00-1-952-941-7600

Transition now

Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.

Web-based seminars

Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.

E-Mail

Ask a question anytime by sending an e-mail to our technical support staff.
[email protected]

Address

Transition Networks
6475 City West Parkway
Minneapolis, MN  55344, U.S.A.
telephone:

952-941-7600

toll free:

800-526-9267

fax:

952-941-2322

Declaration of Conformity

Name of Mfg:

Transition Networks
6475 City West Parkway, Minneapolis MN 55344 U.S.A.

Model:

CFETF1029-2xx Series Media Converters

Part Number(s):

CFETF1029-205, CFETF1029-206, CFETF1029-207, CFETF1029-208, 
CFETF1029-209, CFETF1029-210, CFETF1029-211, CFETF1029-212

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the CFETF1029-2xx to which this declaration refers is in

conformity with the following standards.

CISPR 22:1997+A1: 2000; EN 55022:1998 A1:2000 Class A & B; EN 55024:1998; FCC

Part 15 Subpart B;EN 61000-2-3:1995 A14:2000, EN 61000-3-3:1995; 21 CFR subpart J

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

July 29, 2005_____

Stephen Anderson, Vice-President of Engineering

Date

Содержание CFETF1029-205

Страница 1: ...X receive The CFETF10xx 205 model is the duplex fiber optic version of the media converter For more information see the CFETF10xx 205 user s guide on line at www transition com Installation 2 Operation 5 Cable Specifications 7 Technical Specifications 9 Troubleshooting 10 Compliance Information 12 Part Number Port Two Simplex Fiber Optic 100Base FX CFETF1029 205 RJ 45 100 m 328 ft SC 1310 nm TX 15...

Страница 2: ...w link for a live Web chat 3 Installation Continued Set the AutoCross jumper When the AutoCross feature is activated it allows either straight through or crossover cables to be used when connecting to 100Base TX devices AutoCross determines the characteristics of the connection and automatically configures the unit to link up regardless of the cable configuration The jumper is located on the circu...

Страница 3: ...nk has been established LKC On The copper link has been established RXF Flashing The fiber link is receiving data RXC Flashing The copper link is receiving data Product features Auto Negotiation The Auto Negotiation feature allows the CFETF1029 2xx media converter to automatically configure itself to achieve the best possible mode of operation over a link The media converter broadcasts its speed 1...

Страница 4: ... 00 1 952 941 7600 Far End Fault signal is sent Media Converter A Media Converter B Near End Device Far End Device original fault on the fiber link media converter B disables the copper link media converter A disables the copper link 3 4 2 1 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper link media converter B disables the copper link media conv...

Страница 5: ...35 0 dBm max 3 0 dBm Link Budget 32 0 dB The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC 825 CDRH standards and comply with 21 CFR1040 10 and 21CFR1040 11 techsupport transition com Click the Transition Now link for a live Web chat 9 Technical Specifications For use with Transition Networks Model CFETF1029 2xx or equivalent Standards IEEE 802 3 Data Rate ...

Страница 6: ...cable to restart the initialization process Restart the workstation to restart the initialization process Contact Technical Support 1 800 260 1312 Int l 00 1 952 7600 YES Contact Technical Support 1 800 260 1312 Int l 00 1 952 7600 techsupport transition com Click the Transition Now link for a live Web chat 11 Contact Us Technical support Technical support is available 24 hours a day US and Canada...

Страница 7: ...y to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian regulations This digital apparatus does not exceed the Class A B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriq...