Transition Networks CFETF1011-105 Скачать руководство пользователя страница 5

CFETF10xx-105

8

24-Hour Technical Support: 

1-800-260-1312

-- International: 

00-1-952-941-7600

Cable Specifications

-- Continued

CFETF1011-105

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

CFETF1013-105

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

CFETF1014-105

1300 nm single mode

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Link Budget:

16.0 dB

CFETF1015-105

1300 nm single mode

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -2.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

26.0 dB

CFETF1016-105

1310 nm single mode

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: 0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

29.0 dB

CFETF1017-105

1550 nm single mode

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: 0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

29.0 dB

CFETF1018-105

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -33.5 dBm

max: -14.0 dBm

Link Budget:

14.5 dB

CFETF1019-105

1310nm single mode

Fiber-optic Transmitter Power:

min: -15.2 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.5 dBm

max: -3.0 dBm

Link Budget:

17.3 dB

CFETF1039-105

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

The fiber optic transmitters on this device meet Class I Laser safety
requirements per IEC-825/CDRH standards and comply with 21
CFR1040.10 and 21CFR1040.11.

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

9

Technical Specifications

For use with Transition Networks Model CFETF10xx-105 or equivalent.

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.

Standards

IEEE 802.3™

Data Rate

100 Mb/s

Dimensions

3.4" x 5.0" x 0.87" (86 x 182 x 22 mm)

Weight

3 oz (91 g) (approximate)

Power Consumption

3.5 watts, 200 mA @ 13.9 VDC

MTBF

406,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
1,593,000 hours (Bellcore7 V5.0)

Environment

Tmra*:

0 to 60°C (32 to 140°F )

Storage Temp:  

-20 to 85°C (-4 to 185°F )

Humidity

5 to 95%, non condensing 

Altitude

0 to 10,000 feet

Warranty

Lifetime

*Manufacturer’s rated ambient temperature:  Tmra range for this slide-in-module
depends on the physical characteristics and the installation configuration of the
Transition Networks PointSystem™ chassis in which this slide-in-module will be
installed.  

The information in this user’s guide is subject to change.  For the most up-to-date
information on the CFETF10xx-105 media converter, view the user’s guide on-
line at:  www.transition.com.  

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.

CAUTION:  

Visible and invisible laser radiation when open.  Do not stare into

the beam or view directly with optical instruments.

CAUTION: 

Use of controls, adjustments or the performance of procedures other

than those specified herein may result in hazardous radiation exposure.

Содержание CFETF1011-105

Страница 1: ...physical characteristics of the network installation Part Number Port One Copper 100Base TX Port Two Fiber Optic 100Base FX CFETF1011 105 RJ 45 100 m 328 ft ST 1300 nm multimode 2 km 1 2 miles CFETF10...

Страница 2: ...cently saved on board microprocessor settings Software Mode Hardware Mode H S H S Not Used Link Pass Through up Enable AutoCross up Enable Auto Negotiation up Enable 1 2 3 4 techsupport transition com...

Страница 3: ...s receiving data TX On A link has been established for the copper connection Flashing The copper connection is receiving data Product Features Auto Negotiation The Auto Negotiation feature allows the...

Страница 4: ...www transition com 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper link media converter B disables the copper link media converter A disables the f...

Страница 5: ...iber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC 825 CDRH standards and comply w...

Страница 6: ...RX cables on the media converter are connected to the RX and TX ports respectively on the other device Restart the workstation to restart the initialization process Contact Technical Support 1 800 260...

Страница 7: ...rence regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class...

Отзывы: