Transition Networks CBFTF1011-140 Скачать руководство пользователя страница 3

4

CBFTF10xx-14x

24-Hour Technical Support: 

1-800-260-1312

-- International: 

00-1-952-941-7600

Installation 

-- Continued

Set the Dip Switches -- Continued

NOTE:  Dip switch 4 (in the “SW” set) applies to fiber port 1 (F1).  

4.  Fiber Mode (Fiber Port 1)

UP (Full-Duplex) 

- The cable distances for fiber port

1 (F1) are constrained by the cable requirements (see
pages 1 and 2).

DOWN (Half-Duplex) 

- The cable distances for fiber

port 1 (F1) are constrained by the 512-Bit Rule (see
pages 9). 

NOTE:  Dip switch 5 (in the “SW” set) applies to 

all

twisted-pair copper ports

(TP1, TP2, TP3, TP4).     

5.  AutoCross 

UP (Enable)

- The media converter connects

automatically to either straight-through or crossover
twisted-pair copper cable.

DOWN (Disable)

- Either straight-through or

crossover twisted-pair copper cable must be
installed, according to the site requirements

NOTE:  Dip switch 6 (in the “SW” set) applies to 

both

fiber ports (F1, F2).     

6.  Fiber Redundancy 

UP (Disable)

- When Fiber Redundancy is disabled,

Fiber Port 1 (F1) and Fiber Port 2 (F2) act as normal
bridging ports.

DOWN (Enable)

- When Fiber Redundancy is

enabled, Fiber Port 1 (F1) and Fiber Port 2 (F2) are
configured as either forwarding or disabled.  At any
given time, one port will be disabled and one port
will be forwarding.   

Redundant  Fiber Disable

Redundant Fiber Enable

6

UP

DOWN

Fiber Full-Duplex

Fiber Half-Duplex

DOWN

UP

4

AutoCross Enable

AutoCross Disable

UP

5

DOWN

5

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

Installation 

-- Continued

Set the Dip Switches -- Continued

NOTE:  Dip switches 1, 2, 3, and 4 (in the Config. Switches set) apply 

only

to

twisted-pair copper port 2 (TP2).  

1.  Twisted-Pair Auto-Negotiation

UP (Enabled)

- The media converter “advertises”

ALL rate and mode capabilities to the network:  

• 100Mb/s full-duplex  • 100Mb/s half-duplex,
• 10Mb/s full-duplex    • 10Mb/s half-duplex.  

DOWN (Disabled)

- The bridging media converter

does not “advertise” the rate and mode
capabilities to the network.  

Switch 2

and 

switch 3

are then used to set the twisted-pair rate and mode.  

2.  Twisted-Pair Rate 

UP (100Base-TX)

- Sets the twisted-pair rate to

100Base-TX.

DOWN (10Base-T)

- Sets the twisted-pair rate to

10Base-T.

3.  Twisted-Pair Mode 

UP (Full-Duplex)

- The twisted-pair cable

distances are constrained by the cable
requirements (see pages 1 and 2).

DOWN (Half-Duplex)

- The twisted-pair cable

distances are constrained by the 512-Bit Rule (see
page 9).  

4.  Monitor for Twisted-Pair Port 2 (TP2) 

UP (Off)

- The twisted-pair port 2 (TP2) functions

as directed by 

switches 1

,

2

, and 

3

.

DOWN (On)

- The twisted-pair port 2 (TP2)

functions as a “sniffer” port and transmits all
packets received from ports F1 and TP1. 

Twisted-Pair Full-Duplex

Twisted-Pair Half-Duplex

UP

DOWN

3

Monitor on TP2 OFF

Monitor on TP2 ON

UP

DOWN

4

Twisted-Pair 100Base-TX

Twisted-Pair 10Base-T

UP

DOWN

2

UP

DOWN

1

Twisted-Pair Auto-Negotiation ON

Twisted-Pair Auto-Negotiation OFF

Содержание CBFTF1011-140

Страница 1: ...les CBFTF1017 140 long wave length RJ 45 100 m 328 ft SC 1550 nm single mode 80 km 49 7 miles CBFTF1018 140 RJ 45 100 m 328 ft MT RJ 1300 nm multimode 2 km 1 2 miles CBFTF1025 140 RJ 45 100 m 328 ft MT RJ 1310 nm single mode 5 km 3 1 miles User s Guide CBFTF10xx 14x Slide in Module Media Converter Copper to Fiber 10 100 Bridging 6 Port 4 copper 2 fiber 10 100Base TX to 100Base FX The CBFTF10xx 14x...

Страница 2: ...F1 100Base FX 100Base FX CBFTF140 Installation Continued Set the Dip Switches The dip switches are located on the side of the media converter Use a small flat blade screwdriver or a similar device to set each dip switch SW1 switches 1 6 Dip switches 1 2 and 3 apply only to twisted pair copper port 1 TP1 Dip switch 4 applies to fiber port 1 F1 Dip switch 5 applies to all twisted pair copper ports T...

Страница 3: ... UP 4 AutoCross Enable AutoCross Disable UP 5 DOWN 5 techsupport transition com Click the Transition Now link for a live Web chat Installation Continued Set the Dip Switches Continued NOTE Dip switches 1 2 3 and 4 in the Config Switches set apply only to twisted pair copper port 2 TP2 1 Twisted Pair Auto Negotiation UP Enabled The media converter advertises ALL rate and mode capabilities to the ne...

Страница 4: ...F100 LA PWR RXF RXC LNK COL SPD PWR FRX CRX FLNK CLNK 100BASE TX RX TX 100BASE FX Link Alert E D 0 50 LA PWR RXF RXC LNK COL 10BASE 2 10BASE FL 10BASE T LKS PWR LKM Multimode Singlemode TX RX TX RX I 0 TERM INIT RX TX LNK PWR CPSMM120 SERIAL 10BASE T R E S E T I 0 Panel Fastener Screw Software Mode Hardware Mode H S H S 7 techsupport transition com Click the Transition Now link for a live Web chat...

Страница 5: ...r copper link Flashing Amber Activity on the half duplex copper link Green A link on the full duplex twisted pair copper link Flashing Green Activity on the full duplex copper link Speed LED Amber 10 Mb s operation Green 100 Mb s operation Product Features Full Duplex Network In a full duplex network maximum cable lengths are determined by the type of cables that are used See pages 1 and 2 for the...

Страница 6: ...the ability to force the connection to the desired speed and duplex mode of operation 11 techsupport transition com Click the Transition Now link for a live Web chat Operation Continued Product Features Continued AutoCross When the AutoCross feature is activated it allows either straight through MDI or crossover MDI X copper cables to be used when connecting to 10Base T or 100Base TX devices AutoC...

Страница 7: ...ter Power min 8 0 dBm max 3 0 dBm Fiber optic Receiver Sensitivity min 33 0 dBm max 3 0 dBm Link Budget 25 0 dB The fiber optic transmitters on this device meets Class I Laser safety requirements per IEC 825 CDRH standards and complies with 21 CFR1040 10 and 21CFR1040 11 13 techsupport transition com Click the Transition Now link for a live Web chat Cable Specifications Continued Copper Cable Cate...

Страница 8: ...ted in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s ...

Страница 9: ... by sending an e mail to our technical support staff techsupport transition com Address Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA telephone 952 941 7600 toll free 800 526 9267 fax 952 941 2322 Declaration of Conformity Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model CBFTF10xx 14x Series Media Converters Part Number s CBFTF1011 140 CBF...

Отзывы: