C/T1E1-CF-01 IN THE NETWORK

NOTE: THE C/T1E1-CF-01 REQUIRES A CSU BETWEEN THE MEDIA
CONVERTER AND THE PUBLIC TELEPHONE NETWORK.

Features

Media converter is framing independent (as ESF vs D4) and supports
all common line codes, (AMI, B8ZS, HDB3). 

Distance extensions of 2 km 850 nm multimode or 8 km 1300 nm
singlemode. 

Jitter attenuators optimize Bit Error Rate (BER) performance. 

Dry relay contacts allow media converter to be tied into separate
alarm circuit

All Ones Insertion (AIS), indicated by LEDs, on loss of signal at
copper and/or fiber interface. 

TECHNICAL SPECIFICATIONS

Standards

Emissions: CISPR A

T1/E1 Physical Layer: ITU-T, ANSI, AT&T, ETSI

Case Dimensions

4.75" x 3.0" x 2.0"

(119mm x 76mm x 50mm)

Shipping Weight

3 pounds

(1.4 kilograms)

Delay

400nsec round trip

Environment

Temperature:

0-50°C (32° to 122° F )

Humidity

10-90%, non condensing 

Altitude

0-10,000 feet

Power Supply Requirements Replace power supply with only the equivalent
input rating (see below) and output rating (unregulated 9-24VDC, 5.5W).

TN PN

Requirement

Location

3507

240 volts, 50 hertz

United Kingdom

3342

230 volts, 50 hertz

Europe

3340

120 volts, 60 hertz

USA/Canada/Mexico

3346

100 volts, 50-60 hertz

Japan

3511

240 volts, 50 hertz

Australia

3537

(with power cord: 3522) South Africa

NOTE: This product also can be powered by the Transition Networks E-MCR
series media converter rack. 

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

C/T1E1-CF-01 Series Copper-to-Fiber Media Converter

Part Number:

C/T1E1-CF-01, C/T1E1-CF-01(SC), C/T1E1-CF-01(SM), 
C/T1E1-CF-01(LH)

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the C/T1E1-CF-01 and C/T1E1-CF-01(SM) to which

this declaration refers is in conformity with the following standards.

EMC-CISPR 22: 1985 Class A;  EN 55022: 1988 Class A;  EN 50082-1:1992;
EN 60950 A4:1997;  IEC 801.2, IEC 801.3, and IEC 801.4;  IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_June 8, 1999_____

Stephen Anderson, Vice-President of Engineering

Date

 UTP/STP

Fiber

CSU

To Telco

OR

T1 OR E1 

Network Extension

OR

OR

To Telco

E1

E1

E1

T1 or E1

T1 or E1

T1 or E1

T1 or E1

Содержание C/T1E1-CF-01

Страница 1: ...999 2001 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A 33111 D CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telepho...

Страница 2: ...equirement Location 3507 240 volts 50 hertz United Kingdom 3342 230 volts 50 hertz Europe 3340 120 volts 60 hertz USA Canada Mexico 3346 100 volts 50 60 hertz Japan 3511 240 volts 50 hertz Australia 3537 with power cord 3522 South Africa NOTE This product also can be powered by the Transition Networks E MCR series media converter rack Warranty Lifetime DECLARATION OF CONFORMITY Name of Mfg Transit...

Страница 3: ...hite blue for the active pins Category 3 or better twisted pair copper wire is required Either shielded twisted pair STP or unshielded twisted pair UTP can be used T1 Gauge 24 to 22 AWG Attenuation 2 6 dB 100 meters 1 0 MHz Differential Characteristic Impedance 100 Ω 10 E1 Gauge 24 to 22 AWG Attenuation 2 6 dB 100 meters 1 0 MHz Differential Characteristic Impedance 120 Ω 10 Coax Copper Cable E1 G...

Страница 4: ...es Insertion AIS on the twisted pair interface NO Contact Technical Support 800 260 1312 800 LAN WANS SHORT HAUL Switch Settings Switch 4 UP 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 E1 2 37V 75 ohm cable Coax connectors E1 3 0V 120 ohm cable RJ 45 connector DSX 1 0 133 100 ohm cable DSX 1 133 266 100 ohm cable DSX 1 266 399 100 ohm cable DSX 1 399 533 100 ohm cable DSX 1 533 655 100 ohm cable ANSI T1 4...

Страница 5: ...sted pair cable configuration Check integrity of device attached to media converter by twisted pair cable Contact Technical Support 800 260 1312 800 LAN WANS YES Proceed to step 4 4 Is the AISFiber LED on either media converter illuminated NO Proceed to step 5 YES Determine if broken fiber link has caused All Ones Insertion AIS on the fiber interface and correct failure If not proceed to step 5 Se...

Страница 6: ...build coax cables that are compliant with specifications on page 10 Connect BNC connector at one end of cable to media converter Connect BNC connector at other end of cable to network equipment FIBER Locate or build duplex fiber cables that are compliant with specifications on page 10 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on media c...

Отзывы: