Transition Networks ARCNET AR-CF-01(SC) Скачать руководство пользователя страница 3

TROUBLESHOOTING SUGGESTIONS

If a Media Converter fails, ask the following questions:

1. Is the Power LED on the media converter illuminated?

NO

Is the power adapter the proper voltage and cycle frequency
for the AC outlet? NOTE: Refer to the “Power Supply
Requirements” on the back page. 

Is the power adapter properly installed in the media converter
and in the outlet?

Contact Technical Support: (800) 260-1312/(800) LAN-
WANS.

YES

Proceed to step 2.

2. Is the UTP/STP LED illuminated?

NO

Check twisted pair cables for proper connection.

Check RJ-11 connector for correct twisted pair cable
configuration.

Contact Technical Support: (800) 260-1312/(800) LAN-
WANS.

YES

Proceed to step 3.

3. Is the Fiber LED illuminated?

NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are
connected to RX and TX ports, respectively, on other device.

Contact Technical Support: (800) 260-1312/(800) LAN-
WANS.

YES

Contact Technical Support: (800) 260-1312/(800) LAN-
WANS.

Connect one end of first fiber cable to AR-

CF-01 media converter TX connector.

Connect other end of that fiber cable to second AR-CF-01

media converter RX connector.

Connect one end of second fiber cable to AR-CF-01 media

converter RX connector.

Connect other end of that fiber cable to AR-CF-01 media

converter TX connector.

3. Connect AR-CF-01 media converter near terminal device to terminal

device.

Twisted-pair:

NOTE: Install TRANSITION Networks balun part number: B-4554
between RJ-11 cable and terminal device coax connector.

Install balun at terminal device coax connector.

Connect male RJ-11 plug connector on one end of cable to
female RJ-11 connector marked “UTP/STP” on media
converter.

Connect male RJ-11 plug connector at other end of cable to
balun on terminal device.

Coaxial:

Connect male coax connector on one end of cable to female
RJ-11 connector marked “Coax” on media converter.

Connect male coax connector at other end of cable to female
coax connector on terminal device.

4. Connect AR-CF-01 media converter(s) to power.

Locate correct power supply adapter for site installation. (See
back page.)

Connect media converter power connector at end of power
supply adapter cord to AR-CF-01 media converter power
receptacle.

Connect 2-prong or 3-prong external power connector on
other end of power supply adapter cord to external AC power. 

3

AR-CF-01