Transition Networks 5250-CV-T-F/11 Скачать руководство пользователя страница 5

Twinax to Fiber

2

17

5250 Repeater

Networking the 5250 Repeater

Twinax to Fiber 5250 Repeaters are installed, in pairs, between a host
and remote terminal equipment. The connecting medium between the
pairs is fiber, with optional unshielded twisted pair (UTP) backup. The
connecting medium between the 5250 repeaters and both the host and
the terminal equipment is twinax cable or UTP cable and baluns.

UTP

Terminal
5250 Repeaters

UTP

Host
5250 Repeaters

Fiber

Fiber

Fiber

Twinax

Fiber

Optional
UTP backup

Twinax

Warranty Statement

A. Five Year Warranty

Transition Networks, Inc. (TN) warrants, for a period of five years, that TN products (with
the exception of power supplies and fans that TN warrants for two years) will be free from
defects in materials and workmanship, and will be in conformity with TN’s specifications.

TN’s warranty on products manufactured by or assembled for TN in accordance with a
customer’s specifications, is a five-year warranty that the goods conform to such
specifications.

The warranty is invalidated if the goods have been subject to alterations, misuse, accident,
Acts of God (e.g., damage by floods, lightning strikes, Etc.), tampering, improper
maintenance, improper installation, or abuse. If the user is unsure about the proper means
of installing or using the equipment, contact TN’s free Technical Support or Network
Design Services, which can be reached by:

Telephone

1.800.LAN.WANS or 612.941.7600

Fax

612.941.2322

E-mail

[email protected]

Internet

http://www.transition.com

THE ABOVE WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS
ASSEMBLED BY TRANSITION NETWORKS, INC. TO THE EXTENT PERMITTED BY LAW,
TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES, EXCEPT TITLE,
EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF
DESCRIPTION, MERCHANTIBILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-
INFRINGEMENT, AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL
REPRESENTATIONS REGARDING SUCH PRODUCTS MADE BY TN, ITS EMPLOYEES,
AGENTS, OR REPRESENTATIVES.

B. Limitations and Exclusions

If the customer believes any goods sold by TN are defective and within the warranty period,
the following general procedure will be followed:

1. Locate the serial number and delivery date of the item(s).
2. Notify TN within the warranty period.
3. TN will promptly issue a return authorization form for the goods.
4. Upon receiving the form, the customer will promptly return the item(s) at customers

own expense, shipped prepaid, to the distributor from which it was purchased, or
directly to TN.

TN will only accept goods for return if the following conditions have been met:

1. A return form is obtained from TN.
2. The freight charges have been prepaid by the customer.
3. Goods are re-packed in their original packaging.

If under warranty TN shall, at its option, (1) repair the goods free of charge (2) replace the
goods free of charge, or (3) accept the return of the item(s) and credit the current price to
the reseller (within 90 days of purchase), or (4) if the goods are not under warranty, will
repair the item(s) at a minimum charge of USD $200 (two hundred U.S. dollars) per item.

THIS IS THE EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY. IN NO EVENT
SHALL TRANSITION NETWORKS BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY KIND, WHETHER FOR BREACH OF ANY
CONDITION OF SALE, FOR NEGLIGENCE, ON THE BASIS OF STRICT LIABILITY,
CONTRACT, OR OTHERWISE AND IRRESPECTIVE OF WHETHER TN IS INFORMED BY
CUSTOMER OF THE POSSIBILITY OF SUCH DAMAGES IN ADVANCE OF THIS SALE.

Содержание 5250-CV-T-F/11

Страница 1: ...1 6 165 mm x 105 mm x 41 mm Input Power Power Supply Adapter AC Input TN PN Requirement Location 3500 120 volts 60 hertz 28 watts USA Canada Mexico 3501 230 volts 50 hertz 28 watts Europe 3508 100 volts 50 60 hertz 28 watts Japan 3506 240 volts 50 hertz 28 watts United Kingdom 3510 240 volts 50 hertz 28 watts Australia DC Output 12 volts at 1 5 A maximum MTBF 45655 hours including power supply 525...

Страница 2: ...ty of their respective owners Der Anschluss dieses Gerätes an ein öffentlickes Telekommunika tionsnetz in den EG Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität Twinax Cable...

Страница 3: ...ther shielded twisted pair STP or unshielded twisted pair UTP can be used DO NOT USE FLAT OR SILVER SATIN WIRE Category 3 Gauge 24 to 22 AWG Attenuation 28 dB 1000 10 MHz Differential Characteristic Impedance 100 Ω 10 10 MHz Category 5 Gauge 24 to 22 AWG Attenuation 20 dB 1000 10 MHz Differential Characteristic Impedance 100 Ω 10 10 MHz Minimum Cable Distance Host to Product 7 6 meters 25 feet Pro...

Страница 4: ...d their installation to all persons and from all causes in the aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer s specifications C Return Procedure The customer must f...

Страница 5: ... NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENTATIONS REGARDING SUCH PRODUCTS MADE BY TN ITS EMPLOYEES AGENTS OR REPRESENTATIVES B Limitations and Exclusions If the customer believes ...

Страница 6: ... OUT 5250 CV T F 11 n e t w o r k s T R A N S I T I O N Mpls MN 55344 5 MAINTENANCE WARNING DO NOT UNDER ANY CIRCUMSTANCES open and attempt to repair the 5250 Repeater or power supply adapter unit Failure to observe this warning could result in personal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation Technical Suppo...

Страница 7: ...Fiber UTP Green Flashes rapidly during reception of valid 5250 packet from fiber or UTP connection Sync Twinax Green Flashes rapidly during reception of valid 5250 packet from twinax connection Error Fiber UTP Red Blinks at detection of parity error at fiber or UTP connection Error Twinax Red Blinks at detection of parity error at twinax connection Backup Active Red Illuminated when data reception...

Страница 8: ...ply adapter To cascade 5250 Repeaters 1 Locate the Power OUT receptacle on first 5250 Repeater Pocket Hub 2 Connect one 5250 Repeater DIN cable connector to the 5250 Repeater Power OUT receptacle 3 Connect the other 5250 Repeater DIN cable connector to the Power IN receptacle of an adjacent 5250 Repeater 4 Connect second 5250 Repeater DIN cable connector to the adjacent 5250 Repeater Power OUT rec...

Страница 9: ...tion in country where installed optional DIN cable 5070 for cascading up to four 5250 Repeaters to one power supply adapter User s Guide 7336 Additionally for unshielded twisted pair installations the installation requires Item Part Number baluns 3 4554 RJ 45 3 1143 RJ 11 Connecting Power to 5250 Repeaters NOTE After the power supply adapter is connected to the 5250 Repeater and to external power ...

Страница 10: ...J 11 or RJ 45 plug connector to balun installed on terminal equipment twinax connector UTP Terminal 5250 Repeaters Connecting Host Signal to Host 5250 Repeater Connect the AS 400 S 3X or 5x94 host to the Host 5250 Repeater using either twinax cable or UTP cable and baluns Twinax Connection To connect twinax cable between AS 400 S 3X or 5x94 host and Host 5250 Repeater 1 Locate or build twinax cabl...

Страница 11: ...ns See page 19 straight through cable configuration See page 5 male RJ 11 or RJ 45 plug connectors installed at both cable ends NOTE TRANSITION Network s part numbers for baluns are RJ 45 3 4554 RJ 11 3 1143 Twinax UTP Balun Connection To connect twisted pair cable between host and Host 5250 Repeater using twisted pair cables and baluns 1 Locate or build twisted pair cables with the following char...

Страница 12: ... Repeater either to A or to B Optional UTP Backup Connection To connect twisted pair cable between Host 5250 Repeater and Terminal 5250 Repeater 1 Locate or build twisted pair cables with the following characteristics compliant with cable specifications See page 20 straight through cable configuration See page 5 male RJ 11 plug connectors installed at both cable ends 2 Connect male RJ 11 plug conn...

Отзывы: